• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 175
  • 14
  • Tagged with
  • 189
  • 89
  • 70
  • 49
  • 46
  • 41
  • 39
  • 28
  • 27
  • 26
  • 26
  • 25
  • 25
  • 22
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Strorheter vid bedömning av energieffektivitet för byggnader : En fallstudie för indikator 1 och 3, Miljöbyggnad 3.1

Andersson, Michael, Jonsson, Axel January 2021 (has links)
Sweden uses a large amount of energy within the housing and services sector and there is a greatneed to reduce the energy usage & heat demand of buildings. Using environmental certifications it ispossible to reward buildings that are dimensioned for lower energy usage and low heat demand fromrequirements demanded by the Swedish National Board of Housing, Building and Planning(Boverket). Miljöbyggnad 3.1 (Swedish Green Building Council) Indicator 1 Heat demand is todayassessed in relation to the inside enclosing area of the building, W/m2,Aoms, while Indicator 3 Energyusage is assessed in relation to heated floor area, kWh/m2,Atemp. Previous research indicates that thesequantities do not take into account how well the building is used but only how well it is dimensionedin terms of construction technology. Therefore it might be appropriate to introduce a quantity thattakes into account how well the building is used. The purpose of this case study is to raise a discussion if Boverket and Miljöbyggnad 3.1 today usessuitable quantities when it comes to grade energy efficient building and how different quantities cancome and affect a grading. This research presents a case study where an elementary- and a preschool using IDA ICE-modelsevaluates based on simulations for energy usage and heat demand. The results from the simulationsare compiled in diagrams to be able to see how different cases affect the grading based on whichquantities are being used. The quantities that are being used in this study is based on previousresearch and the different cases have been made to see which parameters affect the quantities. The study shows that depending on what is considered to be an energy efficient building, differentquantities may be applied for the assessment. The quantities used today in Miljöbyggnad 3.1 forIndicator 1 Heat demand and Indicator 3 Energy usage favors different types of buildings.kWh/m2,Aoms favors buildings with higher floor heights while kWh/m2,Atemp favors buildings withlower floor heights.
82

Why buildings’ energy use differ from expected values : A study of sustainable building with focus on the planned area Östra Sala backe

Eriksson, Ida, Pettersson, Lisa, Stadler, Sofia January 2013 (has links)
The municipality of Uppsala together with eight constructors are currently planning a sustainable residential area in Östra Sala backe. The aim of this report is to identify the main factors that are important when calculating the specific energy use in an apartment building. Two previous similar projects, Västra Hamnen in the city of Malmö and Hammarby Sjöstad in the city of Stockholm, are studied and simulations in VIP-energy are performed. Sensitivity analyses concerning the indoor temperature, the efficiency of FTX-systems and the U-values of windows are also executed. The simulations are based on information from the constructors of Östra Sala backe, standard values and mean values from Västra Hamnen and Hammarby Sjöstad. The results show that differences between the estimated and measured values in specific energy use can reach about 50 %, or 25.2 kWh per m2 ATEMP and year, and that the efficiency of the FTX-system is the most important parameter.
83

Skillnaden mellan beräknad och uppmätt energianvändning i två olika kontorshus

Mustafa, Warid, Haidar Ghazi, Hala January 2019 (has links)
Idag finns det ett flertal krav och rekommendationer från myndigheter vilka syftar till att reglera och hålla nere energianvändningen i kontorsbyggnader. I Boverkets byggregler, BBR, finns vägledning till hur kraven kan uppfyllas. Med detta som utgångspunkt genomförs det idag energiberäkningar i projekteringsskedet för att säkerställa att den blivande verkliga energianvändningen ej överstiger den tillåtna. Tidigare studier har visat att det trots detta ändå har varit vanligt förekommande att den verkliga energianvändningen har överstigit den beräknade och i en del fall även den tillåtna.Syftet med denna studie var att undersöka om det föreligger skillnader mellan de beräknade och de uppmätta värdena för kontorshus, samt vilka de bakomliggande orsakerna är. Även en analys kring de olika faktorerna som påverkar energianvändningen har genomförts. Det innebär att för att uppfylla syftet med studien har tre frågor ställts och dessa har besvarats genom undersökningar. Frågorna är: Vad har tidigare studier inom ämnet visat? Vilka orsaker kan det finnas om det uppstår skillnader mellan det beräknade och uppmätta energivärdet? Vad kan göras annorlunda för att få ett bättre resultat?För att kunna besvara frågeställningarna har det samlats in ett års mätningar av energianvändning (uppvärmning, komfortkyla och fastighetsel) för två olika kontorsbyggnader för att kunna visa om det går att bygga energieffektiva lokaler. För respektive kontorsbyggnadhar nödvändig information samlats in från respektive byggherre som har redovisat energiberäkningar med uppskattat energibehov. Den uppmätta uppvärmningen (fjärrvärmeanvändning och uppvärmning av tappkallvatten) har normalårskorrigerats enligt energiindexmetoden för att kunna jämföras med beräknade värden. Litteraturstudie och hypoteser om orsaker till avvikelser mellan beräknat och uppmätt finns användes och analyserades noggrannare för respektive kontorsbyggnad.Den specifika energianvändningen för respektive kontorsbyggnad uppnår Miljöbyggnads kravnivå Brons respektive Silver. För kravnivån Brons gäller att den specifika energianvändningen för en tillbyggnad ska vara under 80 !"ℎ $% och för kravnivån Silver för en ombyggnad under 118 !"ℎ $%. Däremot varierar användningen av energi för uppvärmning och komfortkyla där de månadsvis uppmätta värdena för respektive kontor överstiger det beräknade under året 2017. Det finns flera orsaker till att beräknat energibehov är för lågt på grund av energiberäkningsprogrammet som använts, IDA Indoor Climate and Energy (IDA ICE). En del indata kan ha över- eller underskattats. Exempelvis kan utnyttjandet av tillskottsenergi ha överskattats. För låg innetemperatur och att ingen hänsyn till effekten av köldbryggor tas med kan bidra till att beräknat värmebehov blir för lågt.För att uppnå bättre resultat på de månadsvis uppmätta värdena för kontorsbyggnaderna krävs noggrannare energiberäkningar med realistiska indata, vilket kan innebära att alltför höga värden på energianvändning kan upptäckas och åtgärdas under projekteringsstadiet. Det krävs kunskaper om hur byggnader kan bli energieffektiva vid användning och inte endast när byggnaderna projekteras. / Today, there is a number of requirements and recommendations by government agencies which aim to regulate and reduce energy consumption in office buildings. Boverket Byggregler, BBR, provides guidance on how to meet such requirements. With this as a starting point, calculation to determine energy usage are currently carried out in the design phase to ensure the future energy consumption does not exceed the allowed rate. However, previous studies have shown it is quite common that the actual energy consumption rate exceeds the calculated or even the allowed rate.The purpose of this study is to investigate whether there are differences between the estimated and the measured values for office buildings. Additionally, this review intends to determine the underlying causes of those differences. An analysis of the various factors that affect energy use has also been conducted and the necessary information to complete such analysis has been collected through interviews with the developer.The survey, the actual energy use for the two examined offices exceeds the calculated energy consumption value. Furthermore, the survey shows near large windows, the energy usage was higher due to having more window area, resulting in heat during the summer and needs more energy for cooling down the office buildings.The specific energy use for each office building achieves Miljöbyggnad:s requirement level Bronze and Silver. For the requirement level Bronze, the specific energy use for an extension must be below 80 kWh/m^2 and for the requirement level Silver for a reconstruction shall be 118 kWh/m^2. On the other hand, the use of energy for heating and comfort cooling varies where the monthly measured values for each office exceed that calculated during the year 2017. There are several reasons why estimated energy requirements are too low due to the energy calculation program used, IDA Indoor Climate and Energy (IDA ICE). ), some input data may have been overestimated or underestimated. For example, the use of additional energy can be overestimated, too low indoor temperature and that no consideration of the effect of cold bridges can be included can contribute to the calculated heat requirement being too low. Therefore, it is too early to draw any conclusions as more and more surveys are needed before being able to generalize the results.
84

Digital energistyrning av lägenheter - Är det lönsamt? / Digital power management of apartment houses – Is it profitable?

Lindfors, Hampus, Cedmert, Philip January 2016 (has links)
Äldre flerbostadshus i dagens Sverige använder sig av väldigt mycket energi i onödan. Uppvidingehus är ett fastighetsbolag som anser att deras flerbostadshus har en hög energianvändning. Tre områden i Åseda granskas under denna studie för att se ifall ett digitalt energistyrningssystem kan förminska energianvändningen på dessa områden. Resultatet redovisar vilka byggnader som skulle kunna uppnå en lägre energianvändning och ifall det är lönsamt för ett mindre bostadsföretag att investera i ett digitalt energistyrningssystem.
85

Framtagning av beräkningsmodell för uppvärmningssystem : med fokus på kombinationen fjärrvärme och frånluftsvärmepumpar / Development of a calculation model for heating systems : with focus on the combination of district heating and exhaust air heat pumps

Edström, Johan, Hammar, Samuel January 2016 (has links)
Till följd av EU:s miljömål 2020 har svenska statliga och kommunala miljömål satts upp för att minska energianvändningen. EU:s 2020-mål syftar till att minska energianvändningen i Europa med 20 procent fram till år 2020 från det att målet sattes upp 2010. På kommunal nivå har detta inneburit att fastighetsbolag, privata men främst kommunala aktörer, har tvingats att se över sin energianvändning. Arbetet i denna rapport föranleds av en av de besparingsåtgärder som har vidtagits nämligen att komplettera befintliga fjärrvärmeuppvärmningssystem med värmepumpar. Uppdraget avser utveckling och utvärdering av en beräkningsmodell för denna typ av system. För att skapa ett pålitligt beslutsunderlag i arbetet med att minska energianvändningen krävs välgrundade beräkningar. Befintliga beräkningsmodeller lägger stor vikt vid ekonomiska faktorer och tar därmed liten hänsyn till tekniska aspekter och omgivande faktorer. Målet med arbetet har varit att skapa en beräkningsmodell vilken i större utsträckning speglar den faktiska situationen och påvisar ett mer välgrundat beslutsunderlag. Arbetet inleddes med en litteraturstudie vilken innefattade relevant forskning och grundläggande fakta om värmepumpar och fjärrvärmesystem. Beräkningsmodellen har utvecklats löpande under projektet där nya funktioner samt ny information ständigt tillkommit. Projektet har resulterat i en fungerande beräkningsmodell vilken innefattar fler parametrar än tidigare motsvarigheter. Tillsammans med uppdragsgivaren sattes tre olika mål upp för beräkningsmodellen, dessa var:  Att på ett intuitivt sätt presentera information och data.  Att skapa en transparent struktur vilken är enkel att följa.  Att skapa ett flöde genom modellen vilket följer en önskad arbetsgång. Dessa mål anses ha blivit uppfyllda, dock finns möjlighet till vidareutveckling. Modellen skulle exempelvis kunna kompletteras med mer automatiserade optimeringsberäkningar och justeras för att hantera andra typer av systemlösningar. / As a result of the EU's environmental 2020 goal, the Swedish government and municipal boards has put up internal goals to reduce energy consumption. EU 2020 goal aims to reduce energy consumption in Europe by 20 percent by the year 2020 from that the target was set in 2010. At the municipal level, this has meant that private but mainly public housing properties have been required to review their energy use. The work in this report is based on one of the savings measures that have been taken, which is to supplement existing district heating systems with exhaust air heat pumps. The project aims to develop a calculation model for evaluation and computation for this type of system. To create a reliable basis for decisions, efforts were made to produce just calculations. Existing computational models are focused on economic factors and thus takes little consideration of technological aspects and environmental factors. The aim of the work has been to create a computational model which more closely reflects the real situation and demonstrates a more informative decision basis. The work began with a literature review which included relevant research and basic facts about exhaust air heat pumps and district heating systems. The calculation model has been developed continuously during the project in which new functions and new information constantly has been added. The project has resulted in a working computational model which includes many more parameters than previous reviewed models. Together with the client three sub goals were set up for the model, these were:  To intuitively present information and data.  To create a transparent structure which is simple to follow.  To create a flow through the model, which follows a desired work process. These goals are considered to have been fulfilled in the developed calculation model, however, it's possible to further develop this model. The model could, for example, be supplemented with more automated optimization calculations and be adjusted to handle other kinds of heating systems.
86

Klimatförändringarnas inverkan på inneklimat och energianvändning i passivhus / The impact of climate change on indoor climate and energy use in passive houses

Nylander, Joacim, Sandström, Hugo January 2016 (has links)
Purpose: The purpose of this study is to contribute with knowledge about how the warming effects of climate change may affect indoor living standards, considering that we are already living with some over-temperatures during the summer time. The specific aim is therefore to show how thermal climate in warm passive houses will be perceived, and how specific energy consumption will be affected, within the near future in southern Sweden. Method: To order to achieve the aim, a specific scenario of future temperatures had to be defined. Official climate data for the year 2050 in Gothenburg was collected and compiled. A certified passive house was theoretically exposed to the expected future climate and indoor temperature as well as energy consumption was calculated. Calculations were made using the energy calculation software BV2 for reference conditions and adaptions of both climate as well as technical solutions for greater thermal comfort. Findings: A climate scenario for Gothenburg during year 2050 illustrates that the average year-temperature increases from +7.7°C to +9.9°C. The largest change can be observed during the winter, with an increase peaking at +2.5 ºC. The results show an increase from 65 to 107 number of days during the year in which the studied passive house has an inadequate indoor temperature, as a consequence of over-temperatures. One method for thermal climate enhancing, using a combination of sun screening and air conditioning powered by solar cells, showed having good impact without considerably affecting the specific energy consumption. Implications: In a passive house without air conditioning, the thermal indoor climate will reach an unacceptable level for the tenants, more often in the year 2050, than during the reference period, due to warmer outside temperatures. The method which has the smallest impact upon the energy consumption is sun screening, while air conditioning is the most effective, but also very energy consuming. In order to optimally conserve the thermal indoor climate without decreasing the free energy during the winter, one should install both sun screening and air conditioning in their passive house. Limitations: The result is applicable on passive houses within climate zone III, but the general conclusions made applies for all passive houses in Sweden. Using different methods of calculating the indoor temperature may result in variable results. Keywords: Climate change, Passive house, Indoor climate, Thermal comfort, Energy consumption
87

Miljökonsekvenserna av Växjö kommuns energikrav på bostäder på Östra Lugnet

Johansson, Martina, Petersson, Johanna January 2013 (has links)
I detta examensarbete studeras miljökonsekvenser av Växjö kommuns ställda energikrav på bostadsområdet Östra Lugnet i Växjö. Dessutom studeras hur väl Växjö kommuns och BBRs (Boverkets byggregler) krav på specifik energianvändning efterlevs. Växjö kommuns krav ställs på både företag och privatpersoner där kravet innefattar anslutning till Växjös fjärrvärmenät. Kommunen ställer också krav på företag gällande specifik energianvändning.   Denna studie uppvisar skillnader, både mellan företag och privatpersoner men även mellan företags olika kvarter, i hur väl ställda energikrav efterlevs. Där lyckas företagen sämst, trots att de haft strängare krav.   Studien visar också att fjärrvärme bidrar till en minskning av koldioxidutsläpp, vilket stöder Växjö kommuns kravställande på fjärrvärmeanslutning.
88

Uppvärmning av nybyggda villor - med solfångare och pellets / Heating of newly built one-family houses - with solar panels and pellet

Sjöström, Caroline January 2010 (has links)
Boverket har från och med januari 2010 skärpt energikraven vid nybyggnation. De nya kraven har tillsammans med stigande energipriser och ett ökat miljömedvetande i samhället, satt fokus på att bygga täta och välisolerade hus. Detta beskrivs i arbetets inledning. Samtidigt bör husets uppvärmning och ventilation vara energieffektiv och förnybara energikällor användas, som solenergi och biobränslen. Syftet med rapporten är att analysera om solfångare i kombination med en pelletspanna eller -kamin är ett bra alternativ för uppvärmning av nybyggda villor från VärsåsVillan AB. I rapporten diskuteras detta ur ett miljö-, drifts- och ekonomiskt perspektiv.  Solfångare levererar gratis värme utan miljöpåverkan under drift. Mina beräkningar visar att de kan täcka 30 % av uppvärmningsbehovet i ett lågenergihus. Med stigande energipriser lönar sig solfångare i längden. Pellets är ett förädlat biobränsle med högt energivärde, som med modern utrustning bör betraktas som ett klimatsmart alternativ för småskalig uppvärmning. Solfångare och pellets är en bra kombination både miljö- och driftmässigt. Under sommarhalvåret svarar solfångarna för ca 90 % av uppvärmningen, vilket innebär att pannan eller kaminen stängs av. Under vinterhalvåret blir pelletseldningen effektivare, vilket ger en renare förbränning än under sommaren. Som bas i ett sol-pelletssystem används en 300-750 liters tekniktank, med en elpatron som reserv. Detta ger ett flexibelt system, där gratisenergin från solfångarna utnyttjas i första hand. Även under vår- och höstmånaderna kan värmetillskottet från solfångarna bli relativt stort. Fyra av VärsåsVillans kataloghus valdes till en studie. Husens energianvändning med ett sol-pelletssystem, respektive nya frånluftsvärmepumpen Nibe F750, har beräknats och jämförts. Eftersom nybyggda hus i regel inte har något pannrum är en vattenmantlad kamin ett bra alternativ. Efter påfyllning fungerar den helautomatiskt som en panna, samtidigt som den skapar en trivsam inomhusmiljö. Beräkningarna visar att de studerade husen uppfyller energikraven (BBR) med god marginal om de värms med ett sol-pelletssystem. Om en ventilationsvärmeväxlare installeras sänks behovet av köpt energi med 20-30 kWh/m² och år. Slutsatsen är att ett flexibelt uppvärmningssystem och ett effektivt ventilationssystem ger en energisnål och miljövänlig totallösning, både idag och med tanke på framtidens osäkra energipriser. Solfångare och en vattenmantlad kamin är tillsammans med en ventilationsvärmeväxlare därför en intressant lösning i lågenergihus, framförallt på landsbygden. I tätbebyggda områden är fjärrvärme och solfångare ett lika bra uppvärmningsalternativ. Sol-pelletssystem kan i dagsläget inte konkurrera med frånluftsvärmepumpen ekonomiskt. Investeringskostnaden är betydligt högre, medan driftskostnaderna blir likvärdiga. Samtidigt är frånluftsvärmepumpen ett bekvämare alternativ, vilket gör den till ett attraktivt val för uppvärmning av nybyggda villor. / From January 2010, the National Housing Board has tightened the energy requirements to new buildings in Sweden. The new requirements have together with rising energy prices and an increased environmental awareness in the community, put focus on building tight and well-insulated houses. This is described in the report’s introduction. At the same time heating and ventilation need to be energy efficient and renewable energy sources ought to be used, as solar energy and bio-fuels. The aim of the report is to analyse if solar panels and pellet is a good combination to heat newly built one-family houses from VärsåsVillan AB. The report discusses this from an environmental, operational and economic perspective. Solar panels produce free heat without environmental impact during operation. The calculations show that they can cover 30 % of the heating needs in a low energy house. With rising energy prices, solar panels are profitable in the long run. Pellet is a processed bio-fuel with a high energy content, as with modern equipment is considered as a climate-smart option for small-scale heating. Solar panels and pellet is a good combination, both environmentally and operationally. During the summer half, the solar panels answers for 90 % of the heating needs, which means that a boiler or stove during this time is not in use. In the winter pellet heating becomes more efficient, resulting in less emissions than in summer. The base in a solar-pellet system is a technique tank at 300-750 litres, with an electric heater as backup. This provides a flexible system, using the free energy from the solar panels at first. Even during spring and autumn, solar panels can give a relative large contribution of heat. Four of VärsåsVillan’s houses were selected to a study. The houses’ energy use with a solar-pellet system and a new exhaust air heat pump, Nibe F750, has been calculated and compared. As new houses usually do not have a boiler room, a water-jacketed stove is a good solution. After loading with pellet, it works fully automatic as a boiler, while creating a pleasant indoor environment. The calculations show that the studied houses will meet the energy requirements (in BBR) with a good margin, when they are heated with a solar-pellet system. If a ventilation heat exchanger also is installed, the need for purchased energy is reduced with 20-30 kWh/m² and year. The conclusion is that a flexible heating system and an efficient ventilation system provides an energy efficient and environmentally friendly total solution, both today and in view of future uncertain energy prices. Solar panels and a water-jacketed stove is together with a ventilation heat exchanger, therefore an interesting solution for low energy houses, especially in rural areas. In urban areas, district heating and solar panels is an equally good alternative. Today, a solar-pellet system cannot compete economically with the exhaust air heat pump. The investment cost is considerably higher, while the operating costs will be equivalent. The exhaust air heat pump is also a more comfortable alternative, which makes it to an attractive choice for heating of newly built one-family houses.
89

Fjärrstyrning av fjärrvärmeventiler : Analys och utvärdering / Distance control of district heating valves : Analysis and evaluation

Myrendal, Patrik, Olgemar, Jonas January 2010 (has links)
I detta examensarbete analyseras och utvärderas påverkan av ett system som gör det möjligt att fjärrstyra fjärrvärmeventiler. Principen för systemet är att fastighetens energitillförsel reduceras under kortare stunder, vilket ska åstadkomma vinster för både fjärrvärmeleverantören och fastighetsägaren utan att ha negativ påverkan på inomhuskomforten. Tyngdpunkten i rapporten är att påvisa vilka vinster som kan åstadkommas med en sådan typ av applikation, främst dess påverkan på kundernas fjärrvärmeanvändning och deras effektbehov har studerats. Initiativet till examensarbetet är taget av Tekniska Verken i Linköping AB som under hösten 2009 till våren 2010 har haft ett fjärrstyrningssystem från NODA Intelligent Systems i drift. Systemet har varit installerat på nio större fjärrvärmecentraler i Linköping, sammanlagt cirka 65 000m2 boarea. Systemet har varit i drift veckolånga perioder varvat med opåverkade veckor, detta för att skapa referensdata att jämföra med. All fakta i resultatdelen är hämtade från detta projekt och arbetet med denna rapport har även till en viss del påverkat projektets gång. Utvärderingen visar att systemet ger upphov till en årlig energibesparing på i genomsnitt 5% i de deltagande fastigheterna. Spridningen i resultatet är dock stor, för en av fastigheterna kan ingen energibesparing alls garanteras medan den fastighet som uppvisar bäst resultat uppnår en besparing på drygt 9% av årsanvändningen. Huruvida inomhuskomforten påverkas utav laststyrningen går inte att fastställa av denna utvärdering då antalet mätpunkter för inomhustemperaturen varit begränsat. Möjligheten finns att tillfälligt reducera effektbehovet i fastigheter som fjärrstyrs. En effektreducering på medel 20-30% är möjlig att göra under en tretimmarsperiod. Resultaten från de flesta fastigheterna visar på att reduceringens storlek är som störst den första timmen som fjärrstyrs och avtar under styrningens gång. Efter styrningstillfällen uppkommer det i de flesta fallen ett ökat effektuttag, detta kan uppgå till 13% och risken finns att det ökade behovet kan inverka negativt på fjärrvärmeleverantören. Utvärderingen tyder också på att systemet tillfälligt sänker returledningstemperaturen på primärsidan från de fastigheter som laststyrs, vilket är positivt för fjärrvärmeleverantörer som Tekniska Verken. Om systemet installeras i stor skala i Linköpings fjärrvärmesystem så visar beräkningar att Tekniska Verken skulle göra en mindre vinst. Detta genom att fjärrstyrningen innebär systemövergripande fördelar så som sänkta returledningstemperaturer, minskade produktionskostnader och en möjlighet att tillfälligt reducera effektbehovet hos kund och därmed skulle Tekniska Verken i en viss mån ha möjlighet att styra sin produktion.
90

Energieffektiv projektering : Projektering för ett träffsäkert och energieffektivt slutresultat

Jonsson, Viktor, Lundberg, Mattias January 2010 (has links)
Byggnadssektorn uppskattas idag stå för närmare 40 % av vår totala energiförbrukning, varav nästan 60 % utgörs av uppvärmning och varmvatten. Från myndigheter såväl som allmänheten börjar högre krav ställas på energihushållning i vårt byggnadsbestånd. I media duggar informationen tätt om nya metoder för energieffektivisering, ändå visar statistiken att mycket finns kvar att göra. Frågan som bör ställas är var problemet ligger. Detta examensarbete behandlar projekteringens roll för slutresultatet med avseende på energianvändningen i flerbostadshus. Syftet är att identifiera förbättringsfaktorer för hur projekteringen kan påverka byggprocessen mot ett mer energieffektivt slutresultat. Arbetet grundar sig på tidigare studier och utnyttjar dels en fallstudie av ett 3 st. flerbostadshus i Västerås från 2000-talets början, dels en intervjustudie med fokus på upplevda svårigheter i arbetet med energifrågor bland byggbranschens aktörer. I den inledande litteraturstudien identifierades tekniska och processberoende faktorer som avgör en byggnads energianvändning. Den knyter också an till liknande studier för att tillvarata tidigare erfarenheter. Fallstudien resulterade i att uppmärksamma hur stora konsekvenserna blir av att inte beakta energianvändningen i tillräcklig omfattning. Intervjustudien resulterade i att identifiera likheter och skillnader i de olika aktörernas syn på projekteringen med avseende på byggnaders energianvändning. Bland de förbättringsfaktorer som identifierats bör framför allt en mer framträdande roll hos byggherren nämnas. En tydlig ambitionsnivå för projektet tillsammans med kravformuleringar är också en nödvändighet. Ett samarbete mellan aktörer där all tillgänglig kompetens utnyttjas redan i tidiga skeden krävs också för att kunna beakta energifrågan på allvar. Tekniska konsulter måste ges tillfälle att påverka projektet innan det låsts i alltför stor utsträckning. Fokus genom hela projekteringen bör ligga på ett betraktningssätt där hela byggnaden ses som ett sammanhängande system. Under arbetets gång har också uppmärksammats ett behov av att underlätta uppföljning av utförda byggprojekt. Uppföljning är nödvändigt för att utveckla branschen och frångå ryktet om en byggbransch oförmögen att lära av tidigare misstag. Slutligen kan nämnas att en ökad efterfrågan från samhället måste ske som incitament för byggherren att bygga mer energieffektivt. Samtidigt handlar det för byggherren om att marknadsföra fördelarna med energieffektiva alternativ till konventionella bostäder för att skapa efterfrågan.

Page generated in 0.1556 seconds