• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 247
  • 3
  • 2
  • 1
  • Tagged with
  • 258
  • 76
  • 58
  • 55
  • 54
  • 49
  • 46
  • 40
  • 35
  • 33
  • 32
  • 31
  • 30
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

www.tags.pixos@graffiti.com um rolê pelas ruas da cultura digital

Teixeira, Pedro Luiz Wanderley 24 February 2011 (has links)
Made available in DSpace on 2016-12-08T16:19:08Z (GMT). No. of bitstreams: 1 PEDRO.pdf: 1575259 bytes, checksum: dd85d138802259660db83681f67418cf (MD5) Previous issue date: 2011-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Rolê, in urban slang means to walk around, to go for a walk. Following this definition, this research walks through files posted by urban writers, in the great computer‟s world wide net. The technological advance allowed great changes in the way we communicate to each other. The spaces for human relationship have spread, and are also cyberspace and the rolê now can be digital. To comprehend this dive in the virtual, present in every generation of the XXI century, it is necessary to get to know the origins of the internet e also concepts which refer to the virtual space and the changes in communication towards the digital technological means. The approaches presented here depart from historicities, one about the tags/pixos/graffiti and, in parallel, about the great virtual net. in the arts field, before the internet, some artist developed a world wide connection of files exchange, through the post; highlighted here the Fluxus group, as one of the pioneers. Among innumerous files, pieces of art, photos and cards circulated, which provoked ruptures and a series of transformations in the art institutions and allowed a historical record. In this flow of postal, conceptual, art, the work of Cildo Meireles and Paulo Bruscky consolidated, in Brazil, an artistic production from autonomic spaces, and promoted alternatives circuits of information. Previous to the internet, this artists published their pieces with political and symbolic information and, even towards a military regime, it was possible the circulation of the information among the social environment, using the mass media channels and the traditional exchange systems. In the same way, the urban writers, autonomous, made the polyphonies circulate the digital using the great net as an information exchange channel, as a great advertising, activism and political protagonism tool / Rolê na gíria urbana quer dizer caminhar, dar uma volta. Seguindo esta definição, esta pesquisa caminha por arquivos postados pelos escritores urbanos, nas vias da grande rede mundial de computadores. O avanço tecnológico permitiu grandes mudanças na maneira de nos comunicarmos. Os espaços de relacionamento humano se estenderam, e também são ciberespaço e o rolê agora pode ser também digital. Para compreender este mergulho no virtual, presente em toda a geração do século XXI, é necessário conhecer a origem da internet e também conceitos referentes ao espaço virtual e às mudanças na comunicação diante dos meios tecnológicos digitais. As abordagens aqui apresentadas partem de historicidades, uma sobre os tags/pixos/graffiti e, paralelamente, sobre a grande rede virtual. No campo das artes, anteriores a internet, alguns artistas desenvolveram uma conexão mundial de troca de arquivos, por meio do correio; destaca-se aqui o grupo Fluxus como um dos pioneiros. Dentre os inúmeros arquivos, circulavam obras de artes, fotografias e cartões, que provocaram rupturas e devires nas instituições das artes e possibilitaram um registro histórico. Nesse fluxo da arte postal, conceitual, o trabalho de Cildo Meireles e Paulo Bruscky consolidou, no Brasil, uma produção artística a partir de espaços autônomos, e promoveu circuitos alternativos de informação. Precursores à internet, esses artistas publicaram suas obras com informações de caráter político e simbólico e, mesmo diante de um regime militar, foi possível a circulação da informação pelo meio social, usando os próprios canais de mass media e os sistemas tradicionais de troca. Da mesma forma os escritores urbanos, autônomos, fizeram circular suas polifonias pelo digital usando a grande rede como um canal de troca de informação, como uma grande ferramenta publicitária, ativismo e protagonização política
252

Pichadores e grafiteiros : manifestações artisticas e politicas de preservação do patrimonio historico e cultural da cidade de Campinas-SP / Pichadores and graffiters : artistic manifestations and preservation politics of the historical and cultural patrimony of Campinas-SP

Sales, Ana Celia Garcia de 27 August 2007 (has links)
Orientador: Marco Antonio Alves do Valle / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Artes / Made available in DSpace on 2018-08-11T00:06:31Z (GMT). No. of bitstreams: 1 Sales_AnaCeliaGarciade_M.pdf: 2243726 bytes, checksum: aa650781b36d08c6e99c1707eb6ffbe0 (MD5) Previous issue date: 2007 / Resumo: O presente estudo apresenta dois tipos de intervenção artística no espaço urbano que se manifestam fora dos circuitos consagrados de produção e circulação da arte: a pichação e o graffiti. Pretende-se aqui expor um outro aspecto, além do marginal e transgressor, da pichação e do graffiti, que é sua riqueza como forma de expressão artística e cultural. Para tanto se faz necessário fazer a reconstrução sócio-histórica desses dois movimentos, destacando a forte influência americana. Assim, propõe-se analisar como esses movimentos se efetivam enquanto crítica social e cultural no espaço urbano e discutir as iniciativas do poder público municipal, que integram pichadores e grafiteiros, para a preservação do patrimônio histórico e cultural da cidade de Campinas-SP. Para o desenvolvimento desta pesquisa é importante além dos aspectos já elencados, definir o momento em que a pichação e o graffiti surgem no Brasil, particularmente na cidade de Campinas no contexto de sua evolução como metrópole / Abstract: This work is about two kinds of urban manifestation that happen out of the oficial places of production and circulation of art: the pichação and graffiti. Here we intend to expose another character of the pichação and graffiti ¿ more than the marginal and the criminal character ¿ the artistic and cultural expression. Then, rebuilt the social history of these movements is necessary, emphasizing the strong american influence. So, we propose to analyse how these moviments take part of the urban space, as social and cultural criticism, and discuss the preservation politics of the historical and cultural patrimony of Campinas-SP that cover pichadores and graffiters. For this research is also important to emphasize the moment that the pichação and graffiti arise in Brazil, specially in Campinas in the context of its developing as metropolis / Mestrado / Mestre em Artes
253

Magneto-transporte no limite quântico em grafite e bismuto / Magnet transport in the quantum limit in graphite and bismuth

Medina Pantoja, Juan Carlos 11 August 2018 (has links)
Orientadores: Iakov Veniaminovitch Kopelevitch, George Gershon Kleiman / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-11T13:15:15Z (GMT). No. of bitstreams: 1 MedinaPantoja_JuanCarlos_D.pdf: 3933664 bytes, checksum: 33f9dc730779c11f8c3d83b7ee0e56b4 (MD5) Previous issue date: 2007 / Resumo: Esta tese é o resultado da investigação das propriedades elétricas e magnéticas de dois semimetais: bismuto (Bi) policristalino romboédrico e grafite pirolítica altamente orientada (HOPG). Inicialmente nós discutimos o efeito Hall no limite quântico, que acontece em amostras de grafite HOPG com certo grau de desordem e onde a desordem é reduzida. Em particular, a resistência Hall R xy (B) exibe platôs em amostras HOPG menos desordenadas que possuem uma característica quase-bidimensional e uma forte anisotropia. Em amostras com maior desordem é observada a ocorrência de picos em lugar de platôs, evidenciando, experimentalmente, a predição de T. Ando. A condutância Hall reduzida Rxy (v) G0xy . fornece uma evidencia experimental para a coexistência de ambos os tipos de férmions de Dirac, normais e sem massa. Este resultado revela que o efeito Hall quântico inteiro e semi-inteiro tomam lugar simultaneamente na amostra HOPG. Nós encontramos as transições metal¿isolante (MIT) e isolante¿metal (IMT) induzidas por campo magnético em amostras de bismuto (Bi), quando o campo é aplicado paralelo ao eixo-c cristalográfico e observamos que estas transições têm enormes semelhanças com o MIT e IMT achados em HOPG e amostras monocristalinas Kish. As análises destes resultados experimentais sugerem que estas transições devem estar associadas à transição entre o estado metal de Bose (líquido não superfluido de pares de Cooper) e isolante excitônico. O aumento do momento diamagnético em bismuto e sua supressão próxima do campo crítico do MIT evidenciam a existência de correlações supercondutoras (metal de Bose) e excitônicas. Nós reportamos a observação experimental do efeito Hall anômalo Hall (AHE) em amostras de bismuto e de grafite HOPG. Os resultados indicam que este AHE pode ser compreendido, autoconsistentemente, através de modelos de pareamento excitônico induzido pelo campo magnético, possivelmente, devido ao surgimento de ferromagnetismo / Abstract: This thesis is the result of the investigation of the electric and magnetic properties of two semimetals: highly oriented pyrolitic graphite (HOPG) and polycrystalline bismuth (Bi), rhomboedral. Initially we discuss the Hall effect in the quantum limit that occurs in HOPG samples with a certain degree of disorder and with reduced disorder. In particular, the Hall resistance R xy (B) exhibits plateaus in less disordered HOPG samples, which present characteristic quasi-bidimensional and strongly anisotropic. In more disordered samples there occur peaks instead of plateaus, experimentally evidencing the T. Ando's prediction. The reduced Hall conductance G xy (v)/ G 0xy gives evidence experimental for the coexistence of both massless and massive Dirac fermions. This result reveals that the integer- and semi-integer QHE take place simultaneously in HOPG samples. We observed magnetic field induced metal-insulator (MIT) and insulator-metal (IMT) transitions, when this field is in the crystallographic c-axis direction, and observed that these transitions are very similar to the MIT and IMT observed in HOPG and monocrystalline samples (Kish). The analysis of the experimental results suggests that these transitions must be associated with the transition from the Bose metal state (a non superfluid liquid of Cooper pairs) to the excitonic insulator. The increase of the diamagnetic momentum in bismuth and its suppression in the vicinity of the critical field of the MIT evidences the existence of superconducting (Bose metal) and excitonic correlations. We report the experimental observation of the anomalous Hall effect (AHE) in HOPG samples. This AHE may be autoconsistently understood by means of magnetic field induced excitonic pairing models, possibly, due to the onset of ferromagnetism / Doutorado / Física da Matéria Condensada / Doutor em Ciências
254

Desenvolvimento de metodologias eletroanalíticas para determinação de pesticidas em óleo essencial de laranja / Development of electroanalytical methodologies for pesticides determination in orange essential oil

Fernanda Ramos de Andrade 01 August 2014 (has links)
A citricultura, introduzida no Brasil na época da colonização e explorada comercialmente a partir dos anos 30 do século passado, é um setor de grande importância para o agronegócio brasileiro. Atualmente, o Brasil detém 50% da produção mundial de laranja e cerca de 85% de toda exportação mundial, representando uma captação de divisas de cerca de 2,5 bilhões de dólares por ano, devido principalmente à exportação do suco de laranja. Apesar do suco ser o principal produto de exportação da citricultura, vários subprodutos com valor comercial são obtidos durante seu processo de produção, tais como os óleos essenciais cítricos. Esses subprodutos localizam-se na casca da fruta e são obtidos durante o processo de extração do suco de laranja por prensagem a frio. Devido ao uso intensivo de pesticidas na citricultura e que muitas vezes se acumula na casca da fruta é comum à obtenção de óleos essenciais com resíduos de pesticidas, o que reduz seu preço de mercado internacional e limita sua inserção em mercados exigentes como o Europeu, Japonês e Americano, por exemplo. Este trabalho propõe o desenvolvimento de metodologias eletroanalíticas para a determinação de alguns pesticidas amplamente utilizados na citricultura brasileira e que têm sido encontrados nos óleos essenciais produzidos pelas indústrias de processamento. Inicialmente, foram realizados testes para avaliação da eletroatividade de três pesticidas (piridafention, cihexatina e bromopropilato) amplamente utilizados no Brasil, mas que são proibidos na maioria dos países importadores, sendo, portanto, de importância estratégica. Utilizando-se a técnica de voltametria cíclica verificou-se que o piridafention apresenta resposta sobre o eletrodo compósito de grafite-poliuretana (GPU), a cihexatina apresentou eletroatividade sobre o eletrodo de filme de bismuto e o bromopropilato não foi eletroativo nas superfícies eletródicas testadas. Varreduras realizadas com voltametria cíclica mostraram que o piridafention apresenta um pico de redução em -0,80 V (vs. EECS) sobre eletrodo compósito de GPU em meio ácido (tampão Britton-Robinson 0,1 mol L-1) com características de processo irreversível. Em seguida, desenvolveu-se uma metodologia eletroanalítica, utilizando a técnica de voltametria de onda quadrada (SWV), com a otimização do pH da solução (1,0) e demais parâmetros da SWV como a frequência (80 s-1), amplitude do pulso (50 mV) e incremento de varredura (ΔEi = 5 mV). Curvas analíticas foram obtidas no intervalo de 1,46 a 17,1 µmol L-1, apresentando boa linearidade, com coeficiente de determinação (r2) de 0,998. Os limites de detecção (LD) e de quantificação (LQ) obtidos foram de 0,27 µmol L-1 e 0,92 µmol L-1, respectivamente. A precisão da metodologia desenvolvida foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 98%. A metodologia eletroanalítica desenvolvida para determinação do piridafention foi aplicada em amostras de óleo essencial de laranja, contaminadas com três níveis de concentração 1,5, 2,9 e 5,9 µmol L-1. Foram avaliados quatro procedimentos de extração líquido-líquido, utilizando água Milli-Q como extrator: i) agitação manual da mistura (10 mL de óleo e 10 mL de água) por 4 minutos com repetição do procedimento por 3 vezes; ii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura ambiente; iii) agitação magnética da mistura (5 mL de óleo e 50 mL de água) por 20 minutos em uma única etapa, à temperatura de 45°C; iv) agitação da mistura em mesa orbital com tempo de agitação variando de 5 até 180 minutos. Os melhores resultados foram obtidos com o procedimento utilizando a agitação por mesa orbital (iv), sendo recomendado, portanto, para extração do piridafention em amostras de óleo essencial de laranja. No caso da cihexatina, os testes realizados visando à determinação de uma metodologia eletroanalítica mostraram uma baixa reprodutibilidade do eletrodo filme de bismuto inviabilizando a sua aplicação na eletroanálise da cihexatina. Entretanto, devido à importância da cihexatina e do bromopropilato recomenda-se a realização de mais estudos eletroquímicos com o objetivo de se estabelecer novos métodos de análise. / The citrus production introduced in Brazil during the colonization period and commercially exploited since 1930, is very important for the Brazilian agribusiness. Currently, Brazil is responsible for 50% of the total world citrus production and for about 85% of the citrus world exportation trade, representing an income of about 2.5 billion dollars for the country yearly. The orange juice is the major product of the citrus industry, but other commercially valuable byproducts can be obtained during the manufacturing process, such as the citrus essential oils. These byproduct, located at the orange fruit exocarp, are extracted during the juice production process by cold pressing. Due to the use of pesticides in the citrus production, these agrochemicals can be occasionally presented in extracted essential oil products as unwished residues, which significantly reduce their values in the international market and restrict their insertion in exigent markets as the European, Japanese and North American, for instance. This study aim to develop electroanalytical methodologies for the determination of some pesticides widely employed in the Brazilian citrus production and that has been found in the essential oils produced by the processing industries. Preliminar tests were conducted to evaluate the electroactivity of three pesticides (pyridaphention, cyhexatin and bromopropylate) widely applied in Brazil, but not regulated for use in most of the importing countries. Using the cyclic voltammetry technique, these experiments showed that pyridaphenthion presented a good electrochemical response on the graphite-polyurethane composite electrode (GPU), cyhexatin showed electroactivity on thin bismuth film electrode and bromopropylate was not electroactive on the tested electodes. Studies conducted using cyclic voltammetry showed that pyridaphenthion presents a reduction peak in -0.8 V (vs. ESCE) on GPU in acidic medium (Britton - Robinson buffer 0.1 mol L- 1(BR)) with features of an irreversible process. The electroanalytical methodology for pyridaphenthion analysis was developed using square wave voltammetry (SWV) with optimization of pH (1.0) and the SWV scanning parameters, as pulse frequency (80 s-1), amplitude (50 mV), and increment (ΔEi = 5 mV). An analytical curve was obtained for concentrations ranging from 1.46 a 17.1 µmol L-1, showing good linearity expressed in the determination coefficient (r2) of 0.998. The detection limit (LOD) and quantification limit (LOQ) obtained were 0.27 µmol L-1 and 0.92 µmol L-1, respectively. The precision was evaluated by means its repeatability and reproductibility, while accuracy was assessed by means relative error. Recovery experiments conducted using the standard addition method provided a concentration recovering level of 98%. The electroanalytical methodology developed for pyridaphenthion was applied in citrus essential oil samples spiked with three concentration levels 1.5, 2.9 and 5.9 µmol L-1. Four liquid-liquid extraction procedures were evaluated using only Milli-Q purified water as extracting agent: i) manual stirring of the mixture (10 mL of essential oil and 10 mL of water) during 4 minutes, repeating the procedure three times; ii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at room temperature; iii) magnetic stirring of the mixture (5 mL of essential oil and 50 mL of water) during 20 minutes, in a single step, at 45o C; iv) orbital shaking of the mixture (5 mL of essential oil and 50 mL of water) for different period of times varying from 5 to 180 minutes. The best results were obtained with the procedure using the orbital shaking table (iv), which is, therefore, recommended for extraction of pyridaphention residues in citrus essential oils samples. For the cyhexatin, studies carried out aiming to determine an electroanalytical methodology, showed low reproducibility of the bismuth film, preventing its application in the electroanalysis of cyhexatin. However, due to the importance of these pesticides in citrus essential oils production it is recommended additional studies regarding the electrochemistry and electroanalysis of these chemicals.
255

Estudo da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica com atomização eletrotérmica e detecção simultânea / Study of the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry with simultaneous detection

Correia, Paulo Rogério Miranda 23 July 2004 (has links)
Um estudo sistemático a respeito da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica (ETAAS) foi desenvolvido. O objetivo principal do presente trabalho foi verificar a possibilidade de melhorar a precisão e a exatidão dos resultados analíticos, que são obtidos na análise de fluidos biológicos. O pré-tratamento dessas amostras foi simplificado e reduzido a uma única etapa de diluição com surfactante (Triton X-100) e ácido (HNO3). Conseqüentemente, a complexidade da solução diluída de amostra, a ser introduzida no tubo de grafite, apresenta uma elevada quantidade de concomitantes que podem provocar interferências químicas. A seleção preliminar dos elementos a serem testados como padrão interno considerou a semelhança de parâmetros físico-químicos relacionados com o processo de atomização. Desta forma, Ag, Bi, In e Tl foram testados como padrão interno para a determinação simultânea de Cd/Pb em sangue e urina, enquanto Bi, Ge, In, Sb, Sn e Te foram os elementos selecionados para a determinação de Mn/Ni/Se em soro sangüíneo. A melhoria da qualidade dos resultados analíticos obtidos na determinação simultânea de Cd e Pb em sangue foi observada quando Ag foi utilizada como padrão interno, na presença de NH4H2PO4 como modificador químico. Verificou-se uma melhoria na exatidão dos resultados obtidos para Cd e Pb, após a correção com padrão interno. Por outro lado, os resultados obtidos na análise de urina não foram corrigidos por nenhum dos elementos testados. Os melhores resultados para a determinação simultânea de Mn, Ni e Se foram obtidos com a utilização de Bi, Sn e Te como padrão interno. Entretanto, verificou-se que a correção de todos os resultados não seria viável com o uso de um único padrão interno. O melhor desempenho nos testes realizados na presença de soro sangüíneo foi obtido com Bi, que melhorou discretamente a precisão dos resultados obtidos para Se. Desta forma, a padronização interna visando a determinação simultânea de Mn, Ni e Se não foi eficiente. A padronização interna em ETAAS, com a finalidade de melhorar a precisão e a exatidão dos resultados analíticos, é uma estratégia tão complexa, quanto os efeitos interferentes que se pretende corrigir: são necessários mais estudos para compreender melhor como a utilização de uma condição de compromisso afeta os processos de atomização, bem como mais informações a respeito das interferências físicas e químicas causadas por amostras complexas, analisadas por ETAAS após uma simples etapa de diluição. Deve-se considerar com especial atenção o modificador químico e as temperaturas das etapas de pirólise e de atomização empregadas, que são parâmetros críticos para o desempenho de um elemento como padrão interno. / A systematic study involving the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry was developed. The main objective of this work was evaluate the possibility of improving precision and accuracy of the analytical results for biological fluids. The sample pre-treatment was reduced to a single dilution step with surfactant (Triton X-100) and acid (HNO3), increasing the amount of concomitant introduced into the atomizer. The preliminary selection of the elements to be tested as internal standard considered the resemblance of physico-chemical parameters related with the atomization process. Thus, Ag, Bi, In and Tl were tested as internal standard for the simultaneous determination of Cd/Pb in blood and urine, and Bi, Ge, In, Sb, Sn and Te were the selected elements for the determination of Mn/Ni/Se in blood serum. The correction of the results obtained for the simultaneous determination of Cd and Pb in blood was achieved when Ag was used as internal standard, in presence of NH4H2PO4 as chemical modifier. An improvement for the accuracy of the results was observed for both analytes after their correction with the internal standard. On the other hand, the results obtained for the urine analysis were not corrected by using the tested elements. The best results for the simultaneous determination of Mn, Ni and Se were observed when Bi, Sn and Te were used as internal standard. However, the correction for the results for all analytes was not possible by using only one internal standard. The best performance in presence of the serum was obtained for Bi, which improves slightly the precision for the Se results. Thus, the internal standardization for the simultaneous determination of Mn, Ni and Se was not efficient. The internal standardization in ETAAS, aiming the improvement of precision and accuracy of the analytical results, is a strategy as complex as the interference effects to be corrected: more studies are required in order to better understand how the adoption of a compromised condition disturbs the atomization processes, as well as to get more information about the physical and chemical interference caused by complex samples, analyzed by ETAAS after a single dilution step. The chemical modifier and the selected temperatures for the pyrolysis and atomization steps are critical parameters for the performace of an internal standard and they should be carefully considered.
256

[en] STREET GRAPHIC: STRATEGIES AND TACTICS ON THE STREET VISUAL CULTURE OF RIO DE JANEIRO / [pt] GRÁFICA DE RUA: ESTRATÉGIAS E TÁTICAS NA CULTURA VISUAL DE RUA DO RIO DE JANEIRO

PEDRO SANCHEZ CARDOSO 06 August 2013 (has links)
[pt] Gráfica de rua – estratégias e táticas na cultura visual de rua do Rio de Janeiro é uma investigação sobre o campo da cultura visual de rua. Neste trabalho, observamos uma pluralidade de manifestações visuais – cartazes de lambe-lambe, pixações, grafites, outdoors, banners, impressos volantes, entre outros – objetos que se inserem em um universo dos impressos e através dos quais diversos agentes procuram se fazer representar no espaço público, apropriando-se da rua como um aparato visual. Compreendemos a rua como o lugar de um conflito territorial – uma disputa que se dá no espaço e se manifesta no plano das imagens, através da manipulação, do acúmulo e da sobreposição de indícios visuais. Propomos a noção de capital visual como uma abordagem para as estratégias e táticas de visibilidade levadas adiante pelos diferentes agentes na disputa de poder de que a rua é lugar. / [en] Street Graphic - strategies and tactics on the street visual culture of Rio de Janeiro is a reflection is an investigation about the street visual culture. In this work, we observe the plurality of visual manifestations, such as grafities, billboards, banners, flyers, among others. Objects that are part of the universe of printed forms and through which different agents seek to be represented in public space, by appropriating the street as a visual apparatus. We understand the street as a place of territorial conflict - a dispute that happens in space and manifests in images, through the manipulation, accumulation and overlap of visual clues. We propose the notion of visual capital as an approach to the strategies and tactics of visibility taken forward by the various players in the power struggle that happens in the street.
257

Um método automático para extração em fase sólida magnética de Cd e Pb em águas e de Cd em óleo comestível e detecção por GF AAS

Barreto, Inakã Silva 25 May 2016 (has links)
Submitted by ANA KARLA PEREIRA RODRIGUES (anakarla_@hotmail.com) on 2017-07-31T12:10:23Z No. of bitstreams: 1 arquivototal.pdf: 5468289 bytes, checksum: dc45efa53e8cc6251d00164b611309f9 (MD5) / Made available in DSpace on 2017-07-31T12:10:23Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 5468289 bytes, checksum: dc45efa53e8cc6251d00164b611309f9 (MD5) Previous issue date: 2016-05-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In the last decade, the extraction magnetic solid phase (MSPE) has been intense study target in Analytical Chemistry, mainly because of its potential application in sample preparation. Recently, with the development motivation automatic analytical methods, this technique has been combined with flow systems. However, the synergistic integration of MSPE with these systems is still a challenge, especially when it involves the handling of viscous matrices. In this perspective, this thesis proposes the development of an effective automated method to perform the MSPE in aqueous and oily matrices. For be applied as magnetic adsorbent nanoparticles of Fe3O4 coated with alumina and functionalized with sodium dodecyl sulfate (SDS) and 1-(2-pyridylazo)-2-naphthol (PAN) were synthesized. The nanoparticles were characterized by diffraction analysis X-ray and scanning electron microscopy, where it was confirmed that the method used to obtain the particles was adequate. Secondly, the automatic system to run the MSPE was developed. To this end an extraction chamber was made of Teflon with a quartz window on the side, where all steps of MSPE was performed without the need for any auxiliary apparatus for immobilizing the adsorbent. For generating the magnetic field in the extraction chamber, a robotic device has been developed. After these steps, the applicability of the method was demonstrated in the extraction and preconcentration of Cd and Pb in drinking water samples and Cd in edible oils, using as detection atomic absorption spectrometry graphite furnace. Factors affecting MSPE, such as pH, the amount of adsorbent, the type and concentration of the eluent and the elution time were studied. In the best experimental conditions to the sample water, the detection limit was 0.004, and 0.043 ug L-1 for Cd and Pb, respectively. Even in this array, relative standard deviations less than 3.5% were achieved with a 15-fold enrichment factor for both analytes. In the case of determination of Cd in edible oils, detection limit (0.006 ug L-1) and standard deviation (< 3.3%) was obtained satisfactorily with a 9-fold enrichment factor. Interfering studies have been performed successfully for the two determinations, not revealing significant percentage interference in determinations. The developed automatic method is simple and robust since it does not require immobilization of the adsorbent, and was successfully applied in the determination of Cd and Pb in drinking water samples and Cd in edible oils. / Na última década, a extração em fase sólida magnética (MSPE) tem sido alvo de intenso estudo na Química Analítica, principalmente em virtude do seu potencial de aplicação no preparo de amostras. Recentemente, tendo como motivação o desenvolvimento de métodos analíticos automáticos, essa técnica vem sendo combinada aos sistemas em fluxo. Contudo, a integração sinérgica da MSPE com esses sistemas ainda é um desafio, principalmente quando envolve a manipulação de matrizes viscosas. Nessa perspectiva, a presente tese propõe o desenvolvimento de um eficiente método automático para realização da MSPE em matrizes aquosas e oleosas. Para serem aplicadas como adsorvente magnético foram sintetizadas nanopartículas de Fe3O4 revestidas com alumina e funcionalizadas com dodecil sulfato de sódio (SDS) e 1-(2-piridilazo)-2-naftol (PAN). As nanopartículas foram caracterizadas através da análise de difratometria de raios-X e da microscopia eletrônica de varredura, onde confirmou-se que o método empregado para obtenção das partículas foi adequado. Num segundo momento, o sistema automático para executar a MSPE foi desenvolvido. Para isso, uma câmara de extração foi confeccionada em Teflon, com uma janela de quartzo na lateral, onde todos os passos da MSPE foram realizados sem a necessidade de qualquer aparato auxiliar para imobilizar o adsorvente. Para geração do campo magnético, na câmara de extração, um dispositivo robótico foi desenvolvido. Depois de estabelecida essas etapas, a aplicabilidade do método foi demonstrada na extração e preconcentração de Cd e Pb em amostras de água de abastecimento e de Cd em óleos comestíveis, empregando como detecção a espectrometria de absorção atômica em forno de grafite. Fatores que afetam a MSPE, tais como o pH, a quantidade de adsorvente, o tipo e a concentração do eluente e o tempo de eluição foram estudados. Nas melhores condições experimentais, para a amostra água, o limite de detecção foi 0,004 e 0,043 μg L-1 para o Cd e o Pb, respectivamente. Ainda nessa matriz, desvios padrão relativos menores que 3,5 % foram alcançados com um fator de enriquecimento de 15 vezes para ambos os analitos. No caso da determinação de Cd em óleos comestíveis, limite de detecção (0,006 μg L-1) e desvio padrão relativo (< 3,3 %) satisfatório foi obtido com um fator de enriquecimento de 9 vezes. Os estudos de interferentes foram realizados com êxito para as duas determinações, não revelando interferência percentual significativa nas determinações. O método automático desenvolvido é simples e robusto, uma vez que não requer a imobilização do adsorvente, e foi aplicado com sucesso na determinação de Cd e Pb em amostras de água de abastecimento e de Cd em óleos comestíveis.
258

Estudo da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica com atomização eletrotérmica e detecção simultânea / Study of the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry with simultaneous detection

Paulo Rogério Miranda Correia 23 July 2004 (has links)
Um estudo sistemático a respeito da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica (ETAAS) foi desenvolvido. O objetivo principal do presente trabalho foi verificar a possibilidade de melhorar a precisão e a exatidão dos resultados analíticos, que são obtidos na análise de fluidos biológicos. O pré-tratamento dessas amostras foi simplificado e reduzido a uma única etapa de diluição com surfactante (Triton X-100) e ácido (HNO3). Conseqüentemente, a complexidade da solução diluída de amostra, a ser introduzida no tubo de grafite, apresenta uma elevada quantidade de concomitantes que podem provocar interferências químicas. A seleção preliminar dos elementos a serem testados como padrão interno considerou a semelhança de parâmetros físico-químicos relacionados com o processo de atomização. Desta forma, Ag, Bi, In e Tl foram testados como padrão interno para a determinação simultânea de Cd/Pb em sangue e urina, enquanto Bi, Ge, In, Sb, Sn e Te foram os elementos selecionados para a determinação de Mn/Ni/Se em soro sangüíneo. A melhoria da qualidade dos resultados analíticos obtidos na determinação simultânea de Cd e Pb em sangue foi observada quando Ag foi utilizada como padrão interno, na presença de NH4H2PO4 como modificador químico. Verificou-se uma melhoria na exatidão dos resultados obtidos para Cd e Pb, após a correção com padrão interno. Por outro lado, os resultados obtidos na análise de urina não foram corrigidos por nenhum dos elementos testados. Os melhores resultados para a determinação simultânea de Mn, Ni e Se foram obtidos com a utilização de Bi, Sn e Te como padrão interno. Entretanto, verificou-se que a correção de todos os resultados não seria viável com o uso de um único padrão interno. O melhor desempenho nos testes realizados na presença de soro sangüíneo foi obtido com Bi, que melhorou discretamente a precisão dos resultados obtidos para Se. Desta forma, a padronização interna visando a determinação simultânea de Mn, Ni e Se não foi eficiente. A padronização interna em ETAAS, com a finalidade de melhorar a precisão e a exatidão dos resultados analíticos, é uma estratégia tão complexa, quanto os efeitos interferentes que se pretende corrigir: são necessários mais estudos para compreender melhor como a utilização de uma condição de compromisso afeta os processos de atomização, bem como mais informações a respeito das interferências físicas e químicas causadas por amostras complexas, analisadas por ETAAS após uma simples etapa de diluição. Deve-se considerar com especial atenção o modificador químico e as temperaturas das etapas de pirólise e de atomização empregadas, que são parâmetros críticos para o desempenho de um elemento como padrão interno. / A systematic study involving the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry was developed. The main objective of this work was evaluate the possibility of improving precision and accuracy of the analytical results for biological fluids. The sample pre-treatment was reduced to a single dilution step with surfactant (Triton X-100) and acid (HNO3), increasing the amount of concomitant introduced into the atomizer. The preliminary selection of the elements to be tested as internal standard considered the resemblance of physico-chemical parameters related with the atomization process. Thus, Ag, Bi, In and Tl were tested as internal standard for the simultaneous determination of Cd/Pb in blood and urine, and Bi, Ge, In, Sb, Sn and Te were the selected elements for the determination of Mn/Ni/Se in blood serum. The correction of the results obtained for the simultaneous determination of Cd and Pb in blood was achieved when Ag was used as internal standard, in presence of NH4H2PO4 as chemical modifier. An improvement for the accuracy of the results was observed for both analytes after their correction with the internal standard. On the other hand, the results obtained for the urine analysis were not corrected by using the tested elements. The best results for the simultaneous determination of Mn, Ni and Se were observed when Bi, Sn and Te were used as internal standard. However, the correction for the results for all analytes was not possible by using only one internal standard. The best performance in presence of the serum was obtained for Bi, which improves slightly the precision for the Se results. Thus, the internal standardization for the simultaneous determination of Mn, Ni and Se was not efficient. The internal standardization in ETAAS, aiming the improvement of precision and accuracy of the analytical results, is a strategy as complex as the interference effects to be corrected: more studies are required in order to better understand how the adoption of a compromised condition disturbs the atomization processes, as well as to get more information about the physical and chemical interference caused by complex samples, analyzed by ETAAS after a single dilution step. The chemical modifier and the selected temperatures for the pyrolysis and atomization steps are critical parameters for the performace of an internal standard and they should be carefully considered.

Page generated in 0.1593 seconds