• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 298
  • 195
  • 38
  • 21
  • 18
  • 10
  • 10
  • 10
  • 8
  • 6
  • 6
  • 5
  • 5
  • 2
  • 2
  • Tagged with
  • 701
  • 612
  • 376
  • 275
  • 202
  • 199
  • 126
  • 109
  • 90
  • 78
  • 75
  • 66
  • 64
  • 61
  • 56
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
621

Avaliação polissonográfica do sono induzido pelo propofol em pacientes com SAOS com predomínio no sono REM / Polysomnography evaluation of drug-induced sleep endoscopy with propofol in patients with REM-related obstructive sleep apnea syndrome

Costa, Denise Barreiro 18 May 2016 (has links)
Introdução: A correta localização do sítio de obstrução nas vias aéreas superiores (VAS) possibilita melhores resultados de tratamento para os pacientes com Síndrome da Apneia Obstrutiva do Sono (SAOS). A endoscopia com sono induzido (DISE) com propofol permite esta avaliação, mas o sono induzido pelo propofol altera a arquitetura do sono, abolindo a presença do sono REM (rapid eye movement). Objetivos: Avaliar as alterações promovidas pelo propofol nos principais parâmetros respiratórios por meio do exame de polissonografia (PSG) nos pacientes portadores de SAOS com predomínio no sono REM (SAOS-R). Descrever os achados da DISE nesses pacientes, comparando-os aos achados da manobra de Müller e às descrições na literatura. Casuística e Métodos: Foram estudados 12 indivíduos não obesos com SAOS-R (confirmado por PSG noturna diagnóstica recente), submetidos a dois exames polissonográficos diurnos, com e sem indução do sono com propofol. O propofol foi utilizado via endovenosa em infusão contínua e controlada por bomba de infusão alvocontrolada (Diprifusor®). Os parâmetros comparados entre os exames foram: IAH (índice de apneia e hipopneia), IA (índice de apneia), IH (índice de hipopneia) e saturação de oxi-hemoglobina (SaO2) mínima e média. Além desses parâmetros, os sítios de obstrução das VAS encontrados na DISE foram comparados com os observados na avaliação ambulatorial com os indivíduos em estado de vigília. Resultados: Não foi evidenciado sono REM em nenhum exame realizado com propofol. O IAH, IA e IH do exame com propofol não apresentaram diferença estatística quando comparados com os exames diurnos sem indução e PSG noturna. A SaO2 média apresentou diferença estatística entre os três exames, sendo menor nas PSGs com indução do sono utilizando propofol, tanto em relação ao exame sem sedação (p<0,0001) quanto ao noturno (p=0,004). A SaO2 mínima foi semelhante entre as PSGs com sedação e noturnas, mas foi significativamente menor nos exames com sedação em relação aos sem sedação diurnos (p=0,011). Quando houve diferença significativa, esta ocorreu em torno de 2 a 3%. A análise de concordância para a classificação de VOTE (velum, oropharynx, tongue base and epiglottis) na avaliação ambulatorial e na DISE não demonstrou nenhuma concordância para todas as estruturas avaliadas (Kappa = - 0,029 em palato, 0,1 em orofaringe, 0,16 em base da língua e 0,0 em epiglote). Os resultados demonstraram que, apesar de o propofol influenciar a arquitetura do sono, abolindo o sono REM, os principais parâmetros utilizados na avaliação dos pacientes com SAOS-R, permaneceram inalterados, ou foram clinicamente irrelevantes. Conclusão: Assim, quando utilizado por infusão contínua, o propofol demonstrou ser uma droga segura na avaliação endoscópica dos indivíduos com SAOS-R para a determinação dos sítios de obstrução, acrescentando informações importantes para o correto tratamento. Ainda, a PSG sob sono induzido com propofol manteve os principais parâmetros ventilatórios em comparação à PSG sob sono espontâneo. / Introduction: The correct localization of upper airway obstruction induces the patients with obstructive sleep apnea syndrome (OSAS) to present better treatment results. Drug induced sleep endoscopy (DISE) with propofol allows this evaluation, but changes the sleep architecture, abolishing the presence of REM sleep. Objecives: To evaluate the changes promoted by propofol on the main respiratory parameters of polysomnography (PSG) in patients with REM-related OSAS (REM-OSAS). To describe the endoscopic findings in these patients, and to compare them to the outpatient Müller\'s maneuver and to the findings described in literature. Casuistic and Methods: In this study, 12 non-obese subjects with REM-OSAS (confirmed by recent nocturnal PSG) underwent two polysomnographic examinations during the day, with and without sleep induction with propofol. Propofol was used intravenously in continuous infusion controlled by target-controlled infusion pump (Diprifusor®). The parameters compared between the examinations were: AHI (apnea-hypopnea index), AI (apnea index), HI (hypopnea index) and both minimal and mean oxihemoglobin saturation (SaO2). Besides these parameters the sites of upper airway obstruction found in DISE were compared with those found in awake outpatient evaluation. Results: REM sleep was not achieved in any moment, in any patient, when propofol was infused. The AHI, AI and HI during infusion with propofol showed no statistical difference when compared with both diurnal test without propofol and diagnostic nocturnal PSG. Mean SaO2 showed statistical difference between the 3 tests, being lower in PSG with sleep induction with propofol, both for the exam without sedation (p<0.0001) as for and the diagnostic PSG (p=0.004). Minimum SaO2 was similar between examinations with sedation and diagnostic nocturnal PSG, but it was significantly lower in tests with propofol infusion compared with the diurnal exam without sedation (p=0,011). Mean difference, when significant, was about 2 to 3%. The analysis of agreement for the VOTE classification by patient evaluation and DISE showed no agreement in any measured structure (kappa = -0.029 for velum, 0,1 for oropharynx, 0,16 for tongue base and 0,0 for epiglottis). The results demonstrate that although propofol influences sleep architecture, abolishing REM sleep, the main respiratory parameters remained unchanged in patients with REMOSAS. Conclusions: Thus, target-controlled infusion of propofol is a safe method for endoscopic evaluation of patients with REM-OSAS, in order to determine the sites of obstruction, and it adds important information for proper treatment. Yet, PSG during DISE with propofol was related to manteinance of the most important ventilatory parameters when compared with PSG under spontaneous sleep.
622

Evolução das dimensões da faringe, crescimento craniofacial e sintomas respiratórios em crianças que roncam por aumento das tonsilas faríngea e palatinas tratadas com aparelho ortodôntico Biojusta X / Evolution of the pharyngeal dimensions, facial growth, and respiratory symptoms in snoringchildren with tonsil and adenoid hypertrophy after treatment with the Bioajusta X orthodontic and orthopedic oral appliance

Nunes Junior, Walter Ribeiro 27 February 2013 (has links)
Introdução- Obstrução das vias aeríferas superiores associadas a mudanças nos padrões de sono, estão diretamente relacionados a problemas de crescimento e aprendizagem, o que interfere com a qualidade de vida das crianças com este quadro. Métodos de expansão maxilar já mostraram efeito favorável sobre a função respiratória. Aparelhos removíveis intra-orais têm sido usados no tratamento do ronco e apneia do sono, buscando reequilibrar a postura da mandíbula e da língua para melhorar a função respiratória. O objetivo deste trabalho é avaliar as dimensões da faringe, o crescimento craniofacial e os sintomas respiratórios obstrutivos em crianças com ronco e aumento das tonsilas faríngeas e palatinas em tratamento com um aparelho ortodôntico e ortopédico bucal. Métodos- Quarenta crianças de 6 a 9 anos de idade com tonsilas faríngeas e palatinas graus 3 e 4 e apresentando maxila atrésica e sobressaliência anterior foram divididos em dois grupos aleatórios: 24 pacientes tratados com o aparelho oral e 16 controles não tratados. As dimensões da faringe foram medidas por faringometria acústica. Cefalometria avaliou o crescimento facial, incluindo os valores relacionados com a apnéia do sono. Os pais preencheram questionários sobre os sintomas respiratórios da criança. Os pacientes foram reavaliados após 6 meses, em ambos os grupos. Resultados: A faringometria acústica confirmou um aumento volumétrico de 3,1 cm3 (d.p. ± 2,5) na faringe, no grupo de estudo e uma redução volumétrica de -1,2 cm3 (d.p. ± 1,3) no não tratado (p <0,001). A área mínima de colapsibilidade no grupo de estudo apresentou incremento de 1,1 cm2 (dp ± 0,2) para 1,3 cm2 (d.p. ± 0,2) e uma redução no grupo controle de 1,5 cm2 (dp ± 0,3) para 1,3 cm2 (d.p. ± 0,3) estatisticamente significante (p <0,001). A cefalometria comprovou crescimento craniofacial mais favorável no grupo de estudo, em comparação aos controles, incluindo os valores relacionados a apnéia do sono, como ANB, MMPA e H-ML (p <0,001) . O questionário de sintomas confirmou uma melhoria no padrão de respiração e sono no grupo tratado. Conclusão- As crianças que foram submetidos a esse protocolo de tratamento apresentaram aumento de dimensões da faringe, direção de crescimento mais favorável, e uma melhora na respiração e qualidade do sono / Introduction- Airway obstruction due to associated changes in sleep patterns are directly related to problems of growth and learning, which interfer with the quality of life for these children. Maxillary expansion methods have shown favorable effect on respiratory function. Intra-oral removable appliances have been used in the treatment of snoring and sleep apnea, seeking to rebalance the posture of the jaw and tongue to improve breathing function. The purpose of this thesis is evaluate the facial growth, pharyngeal dimensions and respiratory symptoms in snoring children with enlarged tonsils and adenoids under treatment with an orthodontic and orthopedic oral appliance. Methods- Forty snoring children ages 6 to 9 years old with tonsil and adenoid enlargement grades 3 and 4 and presenting constricted maxilla were divided into two randomized groups: 24 patients treated with the oral appliance and 16 untreated controls. Pharyngeal size was measured by acoustic pharyngometry. Cephalometry evaluated the facial growth including values related to sleep apnea. Pharyngeal size was measured by acoustic pharyngometry. Parents filled out questionnaires about their child\'s respiratory symptoms. Patients were re-evaluated after 6 months, in both groups Results- Acoustic pharyngometry confirmed a volumetric gain of 3.1 cm3 (s.d. ±2.5) in the pharynx at the study group and a volumetric reduction of -1.2 cm3 (s.d. ±1.3) at the untreated (p<0.001). The minimum area on collapsibility at the study group showed an increment from1.1 cm2 (s.d.±0.2) to 1.3 cm2 (s.d.±0.2) and a reduction on the control group from 1.5 cm2 (s.d.±0.3) to 1.3 cm2 (s.d.±0.3) statistically significant (p<0.001). Cephalometry showed a more favorable facial growth on the study group compared to controls, including values related to sleep apnea prediction such as ANB, MMPA and H-ML (p<0.001). The symptoms questionnaire confirmed an improvement on the breathing pattern at the group treated. Conclusions- Children who underwent this treatment protocol presented more favorable growth direction, enlargement of pharyngeal dimensions, and an improvement in breathing and sleep
623

Projeto Jovem Doutor na conscientização da prática de atividades físicas e hábitos saudáveis para a prevenção da síndrome da apneia obstrutiva do sono / Youth Doctor project on awareness of the practice of physical activities and healthy habits for the sleep apnea syndrome prevention

Silva, Vinicius José 23 February 2017 (has links)
A obesidade tornou-se um problema de saúde pública em todo o mundo, devido ao aumento significativo desta doença que é considerada crônica, complexa e multifatorial e responsável por muitos problemas cardiocirculatórios, locomotores, metabólicos e respiratórios, a exemplo da hipertensão arterial, a Síndrome da Apneia e Hipopneia Obstrutiva do Sono (SAHOS), dentre outras. Estudos apontam para uma relação importante, onde crianças e adolescentes com sobrepeso ou obesidade possuem uma maior chance de se tornarem adultos obesos. A presente pesquisa desenvolveu um Programa de Educação em Saúde (PES) com sete encontros a estudantes do 9º ano do Ensino Fundamental II e 1º ano do Ensino Médio de uma escola da rede pública do interior paulista, com o objetivo de sensibilizá-los sobre a importância da prática de atividades físicas e hábitos saudáveis na prevenção da SAHOS e obesidade. O programa foi dividido em três etapas: desenvolvimento, realização e avaliação do PES. Na 1ª etapa, o pesquisador organizou a estrutura básica do programa e elaborou o material. Na 2ª etapa, aconteceram os encontros presenciais com os alunos com aplicação de questionários, avaliação antropométrica, acesso à Plataforma de Aprendizagem Moodle, atividades lúdicas e ação social. Na 3ª etapa, houve a avaliação do PES. Os resultados apontaram que o programa proporcionou aprendizagem significativa aos estudantes sobre os conteúdos desenvolvidos, uma vez que houve a compreensão dos alunos sobre os benefícios da prática de atividade física implementada no cotidiano, assim como a importância dos hábitos alimentares e comportamentais saudáveis para prevenção da Síndrome de Apneia e Hipopneia Obstrutiva do Sono (SAHOS) e obesidade e, por fim, realizou-se a multiplicação do conhecimento à comunidade escolar por meio da ação social tendo como consequência a promoção da saúde com a disseminação das informações aprendidas. / Obesity has become a public health issue throughout the world, due to the significant increasing of this disease, which is considered chronic, complex, multifactorial, and liable for many cardiocirculatory, locomotors, metabolic and breathing problems, such as high blood pressure, Obstructive Sleep Apnea and Hypopnea Syndrome (OSAHS), among others. Studies indicate to an important relation, where children and adolescents overweight or obesity, have a greater chance to become obese adults. The present research has developed a Health Education Program (HEP) with seven meetings to the Ninth grade students of the regular Elementary School II and first year of the High School at a public school in the State of São Paulo, in order to sensitizing them about the Importance to practicing physical activities and healthy habits to the prevention of OSAHS and obesity. The program has been divided into 3 stages: development, implementation and evaluation of HEP. In the first stage, the researcher arranged the basic structure of the program and prepared the material. In the second stage, there were face-to-face meetings with students with questionnaires, anthropometric evaluation, access to the Moodle Learning Platform, playful activities and social action. In the third step, there was the HEP evaluation. The results showed that the program provided meaningful learning for the students about the content developed, since there was the students\' understanding about the benefits of physical activity practice implemented in daily life, as well as the importance of eating habits and healthy behavior for prevention of Obstructive Sleep Apnea and Hypopnea Syndrome (OSAHS) and obesity, and lastly, the multiplication of knowledge to the school community through social action resulting in health promotion with the information learned dissemination.
624

Efeitos hemodinâmicos agudos da pressão positiva contínua na via aérea (CPAP) em indivíduos com cardiomiopatia hipertrófica / Acute hemodynamic effects of continuous positive airway pressure (CPAP) in individuals with hypertrophic cardiomyopathy

Nerbass, Flávia Baggio 13 March 2015 (has links)
Introdução: Apneia obstrutiva do sono (AOS) é uma doença comum em pacientes com cardiomiopatia hipertrófica (CMH) e está associada de forma independente a piora nos seus parâmetros cardíacos. O tratamento da AOS com CPAP (continuous positive airway pressure) é considerado benéfico em pacientes sem CMH. Contudo, o CPAP pode agudamente piorar o desempenho cardíaco em pacientes com CMH e obstrução na via de saída do ventrículo esquerdo (VSVE). Métodos: Foram estudados 26 pacientes com CMH, estáveis, divididos em 12 não-obstrutivos (CMHN-Obst) e 14 obstrutivos (CMHObst), de acordo com seu gradiente de VSVE menor ou maior que 30mmHg, respectivamente. Pacientes foram continuamente monitorados pela pressão arterial (PA) batimento-a-batimento e eletrocardiograma, em vigília e posição supina. Um ecocardiograma bidimensional foi realizado durante o repouso (Basal) a após 20 minutos de CPAP nas pressões de 1,5cmH2O e 10cmH2O, que foram aplicadas em ordem randomizada, interpostas por 10 minutos de intervalo sem CPAP. Em outra data os pacientes foram submetidos a uma polissonografia completa para diagnóstico de AOS. Resultados: Variáveis hemodinâmicas como PA, débito cardíaco, volume sistólico, frequência cardíaca, fração de ejeção do ventrículo esquerdo e gradiente de VSVE permaneceram estáveis ao longo do estudo em ambos os grupos. Em pacientes não-obstrutivos, o CPAP em 10cmH2O reduziu área do átrio direito, a complacência do ventrículo esquerdo, bem como o relaxamento de ambos os ventrículos. Nos pacientes obstrutivos, o CPAP em 10cmH2O provocou efeitos similares no coração direito e também elevou as pressões na artéria pulmonar. No coração esquerdo, houve uma redução na área e volume do átrio esquerdo, com aumento nas áreas e volumes do jato e frações regurgitantes. A polissonografia completa demonstrou que a AOS (índice de apneia e hipopneia >= 15 eventos/hora) estava presente em 58% dos pacientes. Conclusões: O CPAP se mostrou uma alternativa segura para tratar AOS em pacientes com CMH, pois não alterou agudamente a hemodinâmica. Contudo, provocou algumas alterações na dinâmica cardíaca de pacientes obstrutivos, que devem ser considerados com cautela / Background: Obstructive sleep apnea (OSA) is a common disease and is independently associated with a worse in cardiac parameters among patients with hypertrophic cardiomyopathy (HCM). The treatment of OSA with CPAP (Continuous positive airway pressure) is beneficial among patients without CMH. However, CPAP may acutely impair cardiac performance in patients with HCM and left ventricular outflow tract (LVOT) obstruction. Methods: We studied 26 stable HCM patients divided in 12 nonobstructive-HCM and 14 obstructive-HCM according to their LVOT pressure gradient lower or higher than 30 mmHg, respectively. Patients were continuously monitored by beatto- beat blood pressure (BP) and electrocardiogram in the supine position while awake. A 2-dimensional echocardiography was performed at resting (Baseline) and after 20 minutes of nasal CPAP at 1.5cmH2O and 10cmH2O, that was applied in a random order interposed by 10 minutes without CPAP. In another day all patients underwent full Polysomnography for OSA diagnosis. Results: Hemodynamic variables such as BP, cardiac output, stroke volume, heart rate, left ventricular ejection fraction and LVOT gradient did not change along the study period in both groups. CPAP at 10cmH2O in nonobstructive-HCM patients decreased right atrial area, left ventricular compliance, right and left ventricular relaxation. In obstructive-HCM patients, CPAP at 10cmH2O promoted similar effects in the right heart, and also raised pulmonary artery pressure. In the left heart, there was a decrease in left atrial area and volume with increased area and volume of both, regurgitant jet and regurgitant fraction. Full Polysomnography showed that OSA (apneahypopnea index >=15 events/h) was present in 58% of HCM patients. Conclusions: CPAP showed to be safe to treat OSA and did not acutely change hemodynamics in patients with HCM. However, CPAP may acutely impair cardiac dynamics in obstructive-HCM patients and this finding should be carefully considered
625

Aspectos anatômicos da via aérea superior para a personalização da terapia da apneia obstrutiva do sono / Upper airway anatomy characteristics for obstructive sleep apnea personalized treatment

Marques, Melânia Dirce Oliveira 26 November 2018 (has links)
Introdução: A apneia obstrutiva do sono (AOS) é uma doença altamente prevalente, caracterizada pela obstrução recorrente da faringe durante o sono. Apesar do quadro clínico ser marcado por ronco e sonolência diurna excessiva e do maior risco cardiometabólico associado à AOS, uma grande parcela dos pacientes diagnosticados permanece sem nenhum tratamento. Dessa forma, são necessárias estratégias com o objetivo de otimizar as opções de tratamento para os pacientes com AOS. Objetivos: Esta tese é composta pela compilação de três artigos com o objetivo geral de avaliar os fatores fisiopatológicos anatômicos da AOS que podem influenciar na variabilidade individual de resposta ao tratamento. Os objetivos específicos de cada artigo são: Artigo 1) Avaliar se o padrão de obstrução da faringe influencia no efeito da mudança de decúbito de supino para lateral na patência da via aérea superior; Artigo 2) Avaliar as diferenças na complacência das regiões da faringe e sua associação com padrões de curva inspiratória; Artigo 3) Avaliar a influência da estrutura faríngea envolvida na obstrução e a colapsabilidade da via aérea superior na eficácia do aparelho intra-oral (AIO) no tratamento da AOS. Métodos: Foram recrutados pacientes com diagnóstico prévio de AOS com idade entre 21 a 70 anos. Artigo 1: Os indivíduos foram avaliados com sonoendoscopia e registro simultâneo do fluxo aéreo durante o sono natural em decúbito supino e lateral. Artigo 2: os indivíduos foram avaliados com sonoendoscopia e registro simultâneo da pressão faríngea durante o sono natural. Artigo 3: Os indivíduos foram avaliados na primeira noite com sonoendoscopia e, em duas noites adicionais, foram submetidos à polissonografia com e sem AIO para determinação do índice de apneiahipopneia (IAH) e para a medida da pressão crítica de fechamento da faringe (Pcrit). Resultados: Artigo 1: Foram avaliados 24 pacientes (17 homens, idade: 53±6 anos, IAH:48±28 eventos/hora). Em pacientes com obstrução associada a língua (n=10), não houve aumento significativo do pico de fluxo inspiratório e da ventilação minuto com a mudança de decúbito de supino para lateral. A posição lateral resultou em diminuição da ocorrência do colapso de epiglote e aumento de 45% na ventilação minuto entre os pacientes com obstrução da epiglote (n=6). Artigo 2: Foram avaliados 14 pacientes (9 homens, idade: 51±5 anos, IAH: 56±32 eventos/hora). Comparada à região retroglossal, a região retropalatal foi mais estreita (19,2 [23,9] mm2 versus 55,0 [30,7]mm2; p < 0,001) e apresentou maior complacência (3,2 ± 2,1 mm2/cmH2O versus 2,1 ± 1,8 mm2/cmH2O; p < 0,001). A dependência ao esforço negativo foi positivamente associada ao estreitamento da área retropalatal (r=0,47; p=0,001). Artigo 3: Foram avaliados 25 pacientes (17 homens, idade: 49±11 anos, IAH: 51±24 eventos/hora). O AIO reduziu a Pcrit em 3,9±2,4 cmH2O e o IAH em 69%. A redução da Pcrit foi maior nos pacientes com a língua posteriorizada. A ppresença da língua posteriorizada (p=0,03) e menor colapsabilidade da faringe (Pcrit < 1 cmH2O) no momento inicial (p=0,04) foram determinantes de melhor resposta terapêutica demonstrada pela maior redução do IAH com o AIO (83% versus 48%; p < 0,001). Conclusões: O padrão de obstrução e a colapsabilidade da faringe são fatores determinantes na resposta individual às modalidades terapêuticas alternativas para tratamento da AOS como terapia posicional e AIO. Pacientes com colapso de epiglote apresentaram melhora da patência da faringe com o decúbito lateral e assim podem se beneficiar da terapia posicional para AOS. A região retropalatal apresentou menor área e maior complacência comparada à região retroglossal nos pacientes com AOS. Finalmente, pacientes com língua posteriorizada e menor colapsabilidade da faringe são bons candidatos ao uso do AIO para tratamento da AOS / Introduction: Obstructive sleep apnea (OSA) is a highly prevalent disease characterized by recurrent pharyngeal obstruction during sleep. Despite symptoms such as snore and excessive daytime sleepiness and, the higher cardiometabolic risk related to OSA, a large proportion of patients do not receive any treatment for the disease. Therefore, strategies to improve management approaches for OSA are necessary. Objectives: This thesis consists of the compilation of three articles with a general aim of investigating the anatomic factors involved in OSA pathogenesis that could affect the individual variability of treatment responses. The specific aims of each article are: Article 1: To evaluate if the pattern of pharyngeal obstruction influences the effect of changing from supine to lateral position on upper airway patency; 2) To compare the compliance of each pharyngeal level and its association with inspiratory flow patterns; 3) To evaluate the effect of pharyngeal collapsibility and the pharyngeal structure causing collapse on the efficacy of oral appliance therapy for OSA. Methods: Patients previously diagnosed with OSA ranging from 21 to 70 years old were recruited for the studies. Article 1: Patients underwent upper airway endoscopy with simultaneous recordings of respiratory airflow in both supine and lateral position during natural sleep. Article 2: Patients underwent upper airway endoscopy with simultaneous recordings of pharyngeal pressure during natural sleep. Article 3: Patients underwent upper airway endoscopy on the first night. On two additional overnight studies, polysomnography was performed with and without an oral appliance to determine apnea-hypopnea index (AHI), and to measure the critical closing pressure (Pcrit). Results: Article 1: Twenty-four patients (17 men, 53±6 years old, AHI:48±28 events/hour) were studied. Patients with tongue-related obstruction (n=10) showed no improvement in airflow, and the tongue remained posteriorly located. Epiglottic obstruction was virtually abolished with lateral positioning and ventilation increased by 45% compared to supine position. Article 2: Fourteen patients (9 men, 51±5 years old, AHI: 56±32 events/hour) were studied. Compared to the retroglossal airway, the retropalatal airway was smaller at end-expiration (p < 0.001), and had greater absolute and relative compliances (p < 0.001). NED was positively associated with retropalatal relative area change (r=0.47; p < 0.001). Article 3: Twenty-five patients (17 men, 49±11 years old, IAH: 51±24 events/hour) were studied. Oral appliance therapy reduced Pcrit by 3.9±2.4 cmH2O and AHI by 69%. Oral appliance lowered Pcrit by 2.7±0.9 cmH2O more in those with posteriorly-located tongue compared to those without (p < 0.008). Posteriorly-located tongue (p=0.03) and lower baseline collapsibility (p=0.04) were significant determinants of a greater-than-average AHI response to therapy (83% versus 48%, p < 0.001). Conclusions: The pattern of obstruction and pharyngeal collapsibility are determinants of the individual response to alternative OSA treatment such as positional therapy and oral appliance. Patients with epiglottic obstruction showed significant improvement with lateral sleeping position and, therefore may benefit from positional therapy for OSA. The retropalatal airway had a smaller area and a greater compliance compared to the retroglossal airway in OSA patients. Finally, patients with posteriorly located tongue plus less-severe collapsibility are good candidates for oral appliance therapy
626

Meias elásticas compressivas versus CPAP na apneia do sono em pacientes em hemodiálise: um estudo prospectivo e randomizado / Histological comparison between fibers of the palatopharyngeal and superior pharyngeal constrictor muscles in individuals with and without obstructive sleep apnea

Silva, Bruno Caldin da 05 June 2017 (has links)
Introdução: Apneia Obstrutiva do Sono (AOS) é prevalente em estados edematosos, especialmente em pacientes em hemodiálise (HD). Uma vez que o deslocamento noturno de fluidos (DNF) acarreta piora da AOS, nós elaboramos a hipótese de que a interferência na redistribuição de fluidos pelo uso de meias elásticas compressivas (MEC) atenuaria a gravidade da AOS, por mecanismos diferentes em comparação à terapia padrão para AOS, a pressão positiva em vias aéreas (CPAP). Métodos: este é um estudo randomizado e cross-over, que incluiu 14 pacientes dialíticos com AOS (índice de apneia/hipopneia - IAH > 5 eventos/hora) em exame de polissonografia (PSG), que era realizada em três momentos: basal, titulação de CPAP e após uma semana de uso diário de MEC. Circunferência cervical (CC), bioimpedância elétrica segmentar e variabilidade de frequência cardíaca (VFC) foram avaliadas antes e após cada exame de PSG. Resultados: A idade média foi 53±9 anos (57% de homens) e o índice de massa corporal foi 29,7±6,8 Kg/m². O IAH foi reduzido de 20,8 (14,2; 39,6) no exame basal para 7,9 (2,8; 25,4) durante titulação de CPAP e para 16,7 (3,5; 28,9) eventos/hora após uso de MEC (CPAP vs. basal, p=0,004; MEC vs. basal, p=0,017; e CPAP vs. MEC, p=0.017). Comparando basal, CPAP e MEC, o conteúdo de água noturna em membros inferiores foi menor com MEC (p=0,04), enquanto a água intracelular noturna em tronco foi maior (p=0,03). DNF basal, com CPAP e MEC foi de -183±72, -343±220, e -290±213ml, respectivamente (p=0,006). Houve aumento da circunferência cervical durante a noite durante o exame basal (0,7±0,4 cm), mas houve redução dessa circunferência após titulação com CPAP (-1,0±0,4 cm) e após uso de MEC (-0,4±0,8 cm) (CPAP vs. basal, p<0.0001; MEC vs. basal, p=0.001; CPAP vs. MEC, p=0.01). VFC, avaliada pelos componentes de alta e baixa frequência, demonstrou menor ativação simpática durante o exame de titulação de CPAP: OR: 11 (95% CI: 1,06 - 114,2), p=0,025, mas não com MEC: OR: 7,8 (95% CI: 0,75 - 82,2), p=0,059. Conclusões: tanto o CPAP quanto MEC melhoraram AOS em pacientes em HD, mas por mecanismos distintos: enquanto o CPAP reduziu o edema de vias aéreas superiores, ao exercer pressão local, o uso de MEC reduziu o DNF, ao evitar retenção de fluidos em membros inferiores, acumulando água no componente intracelular do tronco. Ativação simpática foi somente reduzida com uso de CPAP. / Background: Obstructive Sleep Apnea (OSA) is prevalent in edematous states, notably in hemodialysis (HD) patients. Once overnight fluid shift (OFS) augments OSA, we hypothesized that interfering in fluid redistribution by wearing compression stockings (CS) would attenuate OSA severity by different mechanisms in comparison to the standard treatment to OSA, the positive airway pressure (CPAP). Methods: This is a randomized crossover study that included 14 dialytic patients with OSA (apnea/hypopnea index - AHI >5 events/hour) by polysomnography (PSG), which was performed in three moments: at baseline, for CPAP titration, and one week after daily wearing of CS. Neck circumference (NC), segmental bioelectrical impedance and heart rate variability (HRV) were assessed before and after each PSG. Results: Mean age was 53±9 years (57% men) and body mass index was 29.7±6.8 kg/m2. AHI decreased from 20.8 (14.2; 39.6) at baseline to 7.9 (2.8; 25.4) during CPAP titration and to 16.7 (3.5; 28.9) events/hour after wearing CS (CPAP vs. baseline, p=0.004; CS vs. baseline, p=0.017; and CPAP vs. CS, p=0.017). Comparing baseline, CPAP and CS, nocturnal lower limbs water content was lower with CS (p=0.04), while nocturnal intracellular trunk water was higher (p=0.03). OFS at baseline, CPAP and CS was -183±72, -343±220, and -290±213ml, respectively (p=0.006). Overnight NC variation increased at baseline (0.7±0.4 cm), but decreased after CPAP titration (-1.0±0.4 cm) and while wearing CS (-0.4±0.8 cm) (CPAP vs. baseline, p<0.0001; CS vs. baseline, p=0.001; CPAP vs. CS, p=0.01). HRV, assessed by both high and low frequency components, showed a lower sympathetic activation during CPAP titration: OR: 11 (95% CI: 1.06 - 114.2), p=0.025, but not with CS: OR: 7,8 (95% CI: 0.75 - 82.2), p=0.059 Conclusions: Both CPAP and CS improved OSA in HD patients by different mechanisms: while CPAP reduced edema in upper airways by exerting local pressure, wearing CS reduced OFS by avoiding fluid retention in the legs, accumulating water in the intracellular component of the trunk. Sympathetic activation was decreased only with CPAP.
627

Télésurveillance nocturne non intrusive de signes vitaux dans des environnements d’assistance à l’autonomie à domicile / Nonintrusive Nocturnal Remote Monitoring of Vital Signs in Ambient Assisted Living Environments

Sadek Ibrahim Hussein Tahoun, Ibrahim 10 April 2018 (has links)
Les approches actuelles pour diagnostiquer les troubles du sommeil sont lourdes, intrusives et peuvent influer sur la qualité du sommeil du patient. Il y a donc un besoin crucial de systèmes moins encombrants pour diagnostiquer les problèmes liés au sommeil. Nous proposons d'utiliser un nouveau système de suivi du sommeil non intrusif basé sur un tapis à fibre optique à microflexion placée sous le matelas de lit. La qualité du sommeil est évaluée en fonction de différents paramètres, y compris la fréquence cardiaque, le rythme respiratoire, les mouvements du corps, l’heure du réveil, la durée du sommeil, le mouvement nocturne et l’heure du coucher. Le système proposé a été validé dans un environnement de santé et de bien-être, en plus d'un environnement clinique comme suit. Dans le premier cas, la fréquence cardiaque est mesurée à partir de signaux ballistocardiogramme bruités acquis de 50 volontaires en position assise à l'aide d'une chaise de massage. Les signaux sont recueillis discrètement à partir d'un capteur de fibre optique microflexible intégrée dans l'appui-tête de la chaise, puis transmis à un ordinateur par une connexion Bluetooth. La fréquence cardiaque est calculée à l'aide de l'analyse multi-résolution de la transformée discrète en ondelettes à chevauchement maximal. L'erreur entre la méthode proposée et électrocardiogramme de référence est estimée en battements par minute en utilisant l'erreur absolue moyenne où le système a obtenu des résultats relativement bons (10.12±4.69) malgré la quantité remarquable d'artefact de mouvement produit en raison des fréquents mouvements corporels et/ou vibrations de la chaise de massage pendant le massage de soulagement du stress. Contrairement à l'algorithme complet de décomposition du mode empirique de l'ensemble, précédemment utilisé pour l'estimation de la fréquence cardiaque, le système proposé est beaucoup plus rapide. Par conséquent, il peut être utilisé dans les applications temps réel. Dans ce dernier cas, nous avons évalué la capacité du capteur de fibre optique microflexible pour suivre la fréquence cardiaque et la respiration d’une manière discrète. En outre, nous avons testé la capacité du capteur dans la discrimination entre la respiration superficielle et pas de respiration. Le capteur proposé a été comparé à un dispositif de surveillance portatif à trois canaux (ApneaLink) dans un milieu clinique au cours d'une endoscopie sous anesthésie. Parmi les dix patients recrutés pour notre étude, le système a obtenu des résultats satisfaisants quant à la fréquence cardiaque moyenne et quant à la fréquence respiratoire moyenne avec une erreur de 0.55 ± 0.59 battements/minute et de 0.38 ± 0.32 respirations/minute, respectivement. De plus, le coefficient de corrélation Pearson entre le capteur proposé et le dispositif de référence était de 0.96 et 0.78 pour la fréquence cardiaque et la respiration, respectivement. Au contraire, le capteur proposé a fourni une très faible sensibilité (24.24 ± 12.81%) et une spécificité relativement élevée (85.88 ± 6.01%) pour la détection de l'apnée du sommeil. On s'attend à ce que cette recherche préliminaire ouvre la voie vers la détection discrète de l'apnée obstructive du sommeil en temps réel. Suite à la validation réussie du système proposé, nous avons déployé avec succès notre système de surveillance du sommeil pendant plus de 6 mois dans treize appartements habités principalement par les personnes âgées. Néanmoins, dans cette recherche, nous nous concentrons sur un déploiement d'un mois avec trois résidents seniors de sexe féminin. Le système proposé montre l’accord avec l’enquête utilisateur recueillie avant l'étude. En outre, le système est intégré dans une plate-forme d’autonomie assistée existante avec une interface conviviale pour rendre plus commode pour les aidants le suivi des paramètres de sommeil des résidents. / The current approaches for diagnosing sleep disorders are burdensome, intrusive, and can affect the patient’s sleep quality. As a result, there is a crucial need for less cumbersome systems to diagnose sleep-related problems. We propose to use a novel nonintrusive sleep monitoring system based on a microbend fiber-optic mat placed under the bed mattress. The sleep quality is assessed based on different parameters, including heart rate, breathing rate, body movements, wake up time, sleep time, night movement, and bedtime. The proposed system has been validated in a health and wellness environment in addition to a clinical environment as follows. In the former case, the heart rate is measured from noisy ballistocardiogram signals acquired from 50 human volunteers in a sitting position using a massage chair. The signals are unobtrusively collected from a microbend fiber optic sensor embedded within the headrest of the chair and then transmitted to a computer through a Bluetooth connection. The heart rate is computed using the multiresolution analysis of the maximal overlap discrete wavelet transform. The error between the proposed method and the reference ECG is estimated in beats per minute using the mean absolute error where the system achieved relatively good results (10.12 ± 4.69) despite the remarkable amount of motion artifact produced owing to the frequent body movements and/or vibrations of the massage chair during stress relief massage. Unlike the complete ensemble empirical mode decomposition algorithm, previously employed for heart rate estimation, the suggested system is much faster. Hence, it can be used in real-time applications. In the latter case, we evaluated the capacity of the microbend fiber optic sensor to monitor heart rate and respiration unobtrusively. In addition, we tested the capacity of the sensor in discriminating between shallow breathing and no breathing. The proposed sensor was compared to a three-channel portable monitoring device (ApneaLink) in a clinical setting during a drug-induced sleep endoscopy. Across all ten patients recruited for our study, the system achieved satisfactory results in the mean heart rate and the mean respiratory rate with an error of 0.55±0.59 beats/minute and 0.38 ± 0.32 breaths/minute, respectively. Besides, the Pearson correlation coefficient between the proposed sensor and the reference device was 0.96 and 0.78 for heart rate and respiration, respectively. On the contrary, the proposed sensor provided a very low sensitivity (24.24 ± 12.81%) and a relatively high specificity (85.88 ± 6.01%) for sleep apnea detection. It is expected that this preliminary research will pave the way toward unobtrusive detection of obstructive sleep apnea in real-time. Following successful validation of the proposed system, we have successfully deployed our sleep monitoring system in thirteen apartments with mainly senior residents over six months. Nevertheless, in this research, we concentrate on a one-month deployment with three senior female residents. The proposed system shows an agreement with a user’s survey collected before the study. Furthermore, the system is integrated within an existing ambient assisted living platform with a user-friendly interface to make it more convenient for the caregivers to follow-up the sleep parameters of the residents.
628

En jämförelse mellan respiratorisk polygrafi och perifer arteriell tonometri i diagnos av obstruktiv sömnapné / A comparison between Peripheral Arterial Tonometry and polygraphy in the diagnosis of Obstructive Sleep Apnea

Starck, Anton, Al-Obaidi, Marwah January 2019 (has links)
Bakgrund: Obstruktiv sömnapné (OSA) är en av de vanligaste kroniska sömnsjukdomarna. Sjukdomen kännetecknas av återkommande episoder med andningsuppehåll under sömn. Detta ligger till grund för dagsömnighet och utveckling av systemsjukdomar. Det finna goda behandlingsalternativ för OSA som CPAP (continuous positive airway pressure), bettskena och kirurgi. Respiratorisk polygrafi (hädanefter presenterad som ”polygrafi”) är standardmetoden i Sverige för att diagnosticera OSA. Perifer arteriell tonometri (PAT) är en alternativ metod. Det finns olika kriterier för tolkning av polygrafi. Detta gör det svårt att jämföra studier. Svenska sömnapnéregistret (SESAR) och berörda specialitetsföreningar har därför tagit fram svenska nationella diagnoskriterier för sömnapné, SESAR-kriterierna. Syfte: Syftet med studien var att utreda om indexvärdena, AHI (apné-hypopné index) och ODI (oxygen desaturation index) överensstämmer i totalen och i olika positioner (rygg och icke-rygg) mellan PAT och polygrafi (tolkad med SESAR-kriterierna), samt att undersöka om det föreligger någon systematisk skillnad mellan dem. Material och metod: Elva patienter registrerades med polygrafi (NOX-T3) och PAT(WatchPAT) under en och samma natt. Registreringarna tolkades med SESAR kriterierna och WatchPAT scoring guidelines. Resultat: PAT visade en stark positiv korrelation med polygrafi (Spearman’s rho=0,771–0,963). Slutsats: Ingen signifikant skillnad hittades mellan PAT och polygrafi. / Background: Obstructive sleep apnea (OSA) is the most common chronic sleep disorder. The disease is characterized by recurrent episodes of respiratory arrest during sleep. This is the basis for daytime sleepiness and development of common systemic diseases. There are good treatment options for OSA including CPAP (continuous positive airway pressure), mandibular advancement splints and surgery. Respiratory polygraphy (hereinafter referred to as “polyhraphy”) is the standard method in Sweden for diagnosing OSA. Peripheral arterial tononometry (PAT) is an alternative method. There are different criteria for interpretation of polygraphy, thus making it difficult to compare studies. Svenska sömnapnéregistret (SESAR) and relevant speciality associations have therefore developed a Swedish national diagnostic criterion for sleep apnea, the SESAR-criteria. Purpose: To investigate if PAT and polygraphy (interpreted with the SESAR-criteria), correspond in apnea-hypopnea index (AHI) and oxygen desaturation index (ODI) and if there is any systematic difference between the methods in different positions (supine and non-supine). Material and methods: Eleven patients were registered with polygraphy (NOX-T3) and PAT (WatchPAT) for one night. The registrations were interpreted with the SESAR-criteria and the WatchPAT scoring guidelines, respectively. Results: PAT showed a strong positive correlation with polygraphy (Spearman’s rho=0,771-0,963). Conclusion: No significant difference was found between methods.
629

Herdabilidade da apneia obstrutiva do sono em uma população rural brasileira / Heritability of obstructive sleep apnea

Paula, Lilian Khellen Gomes de 26 June 2015 (has links)
Introdução: A Apneia obstrutiva do sono (AOS) é uma doença comum na população geral e sua presença pode ser parcialmente explicada por um componente genético. No entanto, existe uma interação grande entre AOS com fatores de confusão, incluindo obesidade. O objetivo principal desse estudo é determinar a herdabilidade da AOS em uma população rural brasileira. Métodos: Foram estudados famílias provenientes de coorte (Corações de Baependi). Os participantes foram avaliados quanto a medidas antropométricas, circunferência de cintura, quadril e pescoço. Aplicamos os questionários de Berlim para determinar o risco de ter AOS, escala de sonolência de Epworth para verificar sonolência excessiva diurna e o questionário de Pittsburgh para verificar a qualidade do sono. Realizamos poligrafia noturna para determinar a presença e gravidade da AOS utilizando o índice de apneia-hipopneia (IAH, definido positivo quando >= 15 eventos/hora). Foi realizada medida de pressão arterial (PA) por meio da monitorização ambulatorial da pressão arterial (MAPA) e velocidade de onda de pulso (VOP) para avaliar rigidez arterial. Resultados: A amostra foi composta de 587 participantes (188 homens e 399 mulheres), com mediana de idade e intervalo interquartil = 44 (29 - 55) anos e IMC = 25,0 (22,1-28,6) kg/m2. Os sintomas sugestivos de AOS derivados dos questionários de Epworth, Berlim e Pittsburgh não se associaram com a presença de AOS; A AOS foi diagnosticada em 18,6% eventos/hora da população, A herdabilidade foi estimada em 26%, independente da obesidade e outros fatores de confusão. A mediana da PA foi mais alta, a ausência de descenso noturno da PA foi mais comum e o VOP mais alto em participantes com AOS do que sem AOS. Na regressão logística multivariada apenas a idade e a PA se associaram de forma significante com o VOP. Conclusões: A herdabilidade da AOS foi moderada (26%) em uma população rural. As alterações cardiovasculares presentes na AOS estão associadas a fatores de confusão em estudos familiares / Introduction: Obstructive sleep apnea (OSA) is a common disease in the general population and the presence can be partially explained by a genetic component. However, there is a strong interaction between OSA with confounding factors, including obesity. The main objective of this study is to determine the heritability of OSA in a Brazilian rural population. Methods: We studied families from the Baependi Heart Study. Participants were assessed for anthropometric measurements, waist, hip and neck circumferences. We used the Berlin questionnaire to determine the risk of having OSA, Epworth sleepiness scale to evaluated the presence of excessive daytime sleepiness and the questionnaire of Pittsburgh to verify the quality of sleep. Overnight Polygraph night was conducted to determine the presence and severity of OSA through the apnea-hypopnea index. Blood pressure was measured (BP) by ambulatory blood pressure (ABP) and pulse wave velocity (PWV) to assess arterial stiffness. Results: The sample consisted of 587 participants (188 men and 399 women), median and interquartile range of age = 44 (29-55) years and BMI = 25.0 (22.1 to 28.6) kg / m2. Symptoms suggestive of OSA derived from Epworth, Berlin and Pittsburgh questionnaires were not associated with the presence of OSA; OSA was diagnosed in 18.6% events/hour of the population, the heritability was estimated at 26%, independent of obesity and other confounding factors. BP was higher, the absence of nocturnal BP was more common and the highest VOP in participants with OSA than without OSA. Using multivariate logistic regression only age and BP were associated significantly with PWV. Conclusions: OSA heritability is moderate (26%) in a rural population. The cardiovascular alterations associated with OSA were explained by confounding factors
630

Apnéia obstrutiva do sono em pacientes portadores da doença pulmonar obstrutiva crônica: impacto do padrão clínico-funcional / Obstructive sleep apnea in patients with chronic obstructive pulmonary disease: impact of the clinical pattern

Cabral, Marília Montenegro 28 February 2005 (has links)
A Apnéia Obstrutiva do Sono (AOS) e a Doença Pulmonar Obstrutiva Crônica (DPOC) são condições clínicas comuns, particularmente na população de idosos, e portanto é de se esperar que um grande número de pacientes com DPOC apresente AOS. Os pacientes portadores da DPOC podem ser divididos em dois tipos clínicos, A e B. O segundo apresenta características clínicas sugestivas da AOS. A prevalência da AOS entre os portadores da DPOC permanece controversa e existem poucos estudos sistemáticos correlacionando a presença da AOS com o tipo clínico da DPOC. Os objetivos primários do nosso estudo foram: (1) determinar a prevalência da AOS em uma população de DPOC e (2) determinar os preditores de risco desta população para AOS. Identificamos 120 pacientes regularmente matriculados no ambulatório de DPOC da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo que preenchiam os critérios para o diagnóstico da DPOC segundo definição da American Thoracic Society. Excluímos os pacientes em programa de oxigenoterapia domiciliar (28 pacientes). Realizamos polissonografia nos 50 primeiros pacientes. Todos foram estudados pelos seguintes métodos: mensuração de dados antropométricos e circunferência do pescoço, escala de sonolência de Epworth, avaliação sobre o ronco, questionário de Berlin, gasometria arterial em ar ambiente e vigília e prova de função pulmonar completa com mensuração da capacidade de difusão do monóxido de carbono (DLco). Os pacientes foram classificados em tipo A (DLco < 50% do valor normal previsto e dispnéia como sintoma predominante), B (DLco > 50% do valor normal previsto e tosse crônica com produção de expectoração como sintoma predominante) e misto. A população estudada se constituiu de 40 homens e 10 mulheres, com idade de 64±9 anos, índice de massa corpórea de 24±5 kg/m2 e VEF1 de 43±15% do valor normal previsto. Dezoito pacientes foram classificados em tipo A, 17 em tipo B e 15 em tipo misto. A AOS (índice de apnéia/hipopnéia > 15 eventos/hora) foi encontrada em 14 pacientes (28%). A prevalência da AOS foi maior na DPOC tipo B (47%) do que na DPOC tipo A (p<0,05). A análise de regressão logística multivariada mostrou que a presença de ronco, a grande circunferência do pescoço e a DPOC tipo B foram todos preditores independentes de risco para AOS. Concluímos que a AOS é freqüente entre portadores da DPOC, particularmente na DPOC tipo B / Chronic obstructive pulmonary disease (COPD) and obstructive sleep apnea (OSA) are common diseases, particularly in elderly patients, and therefore OSA is likely to occur in COPD patients. It was long observed that chronic obstructive pulmonary disease may fall in two distinct clinical pattern: type A (pink puffer) and type B (blue bloater). Type B patients resemble those of patients with OSA. The prevalence of OSA in COPD patients remains controversial and there are few studies that have investigated the presence of OSA according to the clinical characteristics. Our primary aims were: (1) determine the prevalence of OSA in COPD patients and (2) identify predictors for OSA in COPD patients. For this purpose we studied 50 consecutive non-oxygen dependent patients with a diagnosis of COPD as defined by the American Thoracic Society, who were attended at outpatient COPD clinic at a tertiary University Hospital. The patients were then classified as type A, type B and mixed. Type A COPD was defined solely on the basis of by a DLco < 50% of that predicted. Patients with DLco >= 50% were classified as type B only if they had a clear history of chronic cough and sputum production, lasting for at least 3 months per year for 2 years. All patients were studied by full polysomnography. Prior to sleep study, all patients underwent routine pulmonary function testing including measurement of lung volumes and DLco by the single breath technique. The Epworth Sleepiness Scale and Berlin questionnaire were completed. Snoring was considered present if it was loud and frequent. Neck circumference was also determined. There were 40 males (80%), age 64±9 years old, body mass index 24±5 kg/m2, forced expiratory volume in the first second 43±15% of predicted. Eighteen patients were classified as Type A, 17 as Type B and 15 as Mixed. Obstructive sleep apnea (apnea-hypopnea index > 15 events/hour) was observed in 14 (28%) patients. The prevalence of obstructive sleep apnea was significantly higher in Type B patients (47%). Multiple logistic regression analysis showed that presence of snoring, large neck circumference, type B were all independent predictors for OSA. We conclude that OSA is common among COPD patients, particularly among patients with type B pattern

Page generated in 0.035 seconds