• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 84
  • 32
  • 28
  • 6
  • 3
  • 2
  • 1
  • Tagged with
  • 156
  • 112
  • 54
  • 48
  • 43
  • 36
  • 25
  • 22
  • 20
  • 19
  • 19
  • 18
  • 17
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Revision i en miljö präglad av en pandemi : En kvalitativ studie om hur revisorer vid små och medelstora revisionsbyråer upplever digitaliseringsutvecklingen inom ramen för Covid-19 pandemin. / Audit in an environment characterized by a pandemic : A qualitative study about how auditors in small and medium sized audit firms experience the digitalization development within the context of the Covid-19 pandemic.

Hansson, Paulina, Petersson, Sigrid January 2022 (has links)
Bakgrund: Revisionsyrket befinner sig i en digitaliseringsutveckling och den får en allt mer betydande roll inom revisionen. En tillkommande faktor till denna utveckling är Covid-19 pandemin vilken har inneburit social distansering vilket kan ha påverkat revisorernas arbetssätt. Syfte: Syftet med den här studien är att bidra med fördjupad kunskap om hur revisorer vid små och medelstora revisionsbyråer upplever digitaliseringsutvecklingen inom ramen för Covid-19 pandemin. Metod: Studien tillämpar en deduktiv ansats. Utifrån den teoretiska referensramen utformas intervjustudien där legitimitetsteori och komfortteori appliceras. Urvalet för denna grundar sig på en förstudie vilken består av en enkät konstruerad utifrån urvalskriterier för intervjuerna. Slutsats: Studien visar att revisorerna upplever att pandemin har påskyndat digitaliseringen. Den största förändringen som går att utläsa är kommunikationen mellan revisor och kund som blivit mer digital. Även insamlingen av revisionsbevis upplever revisorerna har påverkats, främst gällande inventeringen. Att detta digitaliserats är något som flera av revisorerna upplever har påverkat deras trygghet. Utifrån revisorernas upplevelser går det även att se en potentiell påverkan på oberoendet och därmed legitimiteten. / Background: The auditing profession is in the midst of a digitalization development and it gets an increasingly important role within the audit. An additional aspect to this development is the Covid-19 pandemic which has led to social distancing that may have affected the auditors’ work. Purpose: The aim of this study is to contribute with a deeper knowledge about how auditors in small and medium sized audit firms experience the digitalization development within the context of the Covid-19 pandemic. Method: The study applies a deductive approach. The interview study is designed based on a theoretical framework where legitimacy theory and comfort theory are applied. The selection for the interview study is based on a pre-study which consists of a form constructed from the selection criteria for the interviews. Conclusion: The study shows that the auditors feel that the pandemic has accelerated the digitalization. The most distinct change is the communication between auditor and client which has become more digital. The collection of audit evidence is also something that the auditors experience has been affected, especially concerning the inventory. Several of the auditors feel that this has affected their feeling of comfort. The auditors' experiences show a potential impact on the independence and hence the legitimacy.
102

Seat belt and headrest adjustment: Increasing truck driver comfortability / Justering av säkerhetsbälte och nackstöd: Komfortförbättring av förarstolen ilastbilar

Berg, Kathrine, Petersson, Elinor January 2017 (has links)
Truck drivers spend long, consecutive periods of time seated down, and the truck cab becomes their immediate work environment. Therefore, it is important to make sure that this space is properly adapted to fit the driver’s needs well. The driver seat is something the driver are very much in contact with. The seat can be adjusted in many ways to accommodate for drivers of different heights and body types. However, two of the components which are fixed today are the upper seat belt anchorage position and the headrest. In this thesis project, the aim has been to investigate the adjustment possibilities of these components in terms of desired adjustment range and mechanical solutions. The first part of the project was spent on ergonomic evaluations of the seat, and finding what properties are the most important when designing a truck seat. Both literature reviews as well as interviews and observations helped build the knowledge foundation to base adjustment concepts on. For example, it was found that to minimise the negative effects of sedentary work, the single most important action is to frequently change the sitting position. Therefore, it is of high importance that adjustment procedures are as simple as possible. It was also found that many truck drivers do not use their seat belt at all, and that having a headrest which is adjustable in height is important for the driver’s visual area. Several ideas and concepts were generated and evaluated. The initial ideas included both solutions applicable on the current seat belt design, while some would use other means of securing the driver in a collision. The ideas were compared and evaluated, and three were chosen to develop further; one being easy to implement, and two being mechanical solutions both making use of the current seat belt design. These three concepts were investigated more deeply, and were subsequently also compared using different methods for evaluation. Eventually, a final concept was chosen; a mechanical solution in which the seat belt and headrest can be adjusted separately in one and two directions respectively. This concept was further developed in terms of both mechanical as well as visual design. In the final concept, Hoop, the seat belt is adjusted sideways, as this was proven to give the largest comfortability improvement for the driver. The headrest is adjustable in both height and depth. The mechanisms are locked using ratchets, however, both can be adjusted in what is believed to be the most critical direction without the need to unlock first. The buttons for unlocking the mechanisms are placed directly on the adjustment mechanisms in order to keep the procedure as intuitive and easy to use as possible. The adjustment ranges were determined based on Scania’s anthropometric dataset in order to make sure that the adjustment features will be useful for an as large part of the driver population as possible. / Lastbilschaufförer tillbringar under sina arbetspass många timmar i lastbilshytten, som blir deras direkta arbetsmiljö. Det är därför viktigt att hytten är utformad utifrån föraren och dennes behov. Förarstolen är en av de komponenter som föraren har allra mest kontakt med. Denna kan justeras på många sätt för att möjliggöra för förare av olika längder och kroppstyper att hitta en körposition som passar just dem. Två komponenter som dock inte kan justeras i dagsläget är positionen av den övre bältesomlänkaren och nackstödet. I detta examensarbete har fokus varit att ta fram hur justering för dessa skulle kunna se ut både i form av önskat justerområde och mekaniska lösningar. Projektets inleddes med en ergonomisk undersökning för att hitta de viktigaste fokusområdena för just lastbilars förarstolar. Informationen hämtades dels från litteratur, och utöver detta gjordes även användarundersökningar genom en enkät, kontextuella intervjuer och observationer. En av de viktigaste insikterna från undersökningen var att det absolut viktigaste för att undvika negativa effekter av stillasittande arbete är att kontinuerligt ändra sin sittposition. Ett effektivt sätt att få fler förare att använda justeringsfunktionerna på detta sätt kan vara att placera kontroller väl åtkomliga och göra justeringsproceduren så lättförståelig och lättanvänd som möjligt. Dessutom är det mycket viktigt att ett nackstöd kan justeras inte bara ur komfortsynpunkt, utan här finns det även en stark säkerhetsfaktor kopplad till förarens synfält. Baserat på informationssökningen genererades därefter flera olika lösningsidéer, där vissa låg närmre dagens lösning än andra. Dessa evaluerades sedan med hjälp av bland annat beslutsmatriser, och tre idéer valdes att utveckla vidare till tydligare koncept. Av de tre idéer som valts ut var en lösning enkel att implementera och två var olika mekaniska lösningar, alla applicerbara för den nuvarande bältesformen. Dessa detaljerades och kombinerades samman med hjälp av en morfologisk matris, och jämfördes sedan gentemot varandra. Slutligen valdes ett koncept ut som det slutgiltiga, där bältesomlänkaren kan justeras i en riktning och nackstödet i två. Detta slutkoncept utvecklades ytterligare vad gäller den mekaniska lösningen och dess visuella form. I slutkonceptet, Hoop, kan bältesomlänkaren justeras i sidled, eftersom denna justeringsriktning i den ergonomiska undersökningen visade sig ge störst resultat för förarens komfort. Nackstödet kan justeras både i höjd- och i djupled. Båda mekanismerna låses med hjälp av geometriska spärrlåsningar, men kan justeras i en riktning, den som ses som mest kritisk att snabbt kunna justera i, utan att föraren först behöver låsa upp mekanismen. Knapparna för att låsa upp mekanismerna är placerade i direkt anslutning till området där själva rörelsen sker för att göra användandet så intuitivt som möjligt. Justerområdena har baserats på antropometriska mått hämtade från Scaniafamiljen för att försäkra om att de täcker in så stor del av förarpopulationen som möjligt.
103

A hybrid low - temperature heating system in geothermal retrofitting for public buildings in the Mediterranean climate

Bizimana, Boumediene January 2019 (has links)
More than 50 % of EU’s yearly energy demand is spent on heating and cooling systems with which most of its source is generated from non-renewable fossil fuel [1]. Furthermore, half of the EU buildings are heated with a non-efficient boiler of about 60% or less efficiency [1]. The report released by EU from 1990 to 2007 revealed that fuel combustion and fugitive emission contribute to about 79.3% of total greenhouse gas emissions in CO2 equivalents [1]. The EU-EBPD long-term renovation strategy is to improve the energy performance of all residential and non-residential buildings in its member countries through supporting the renovation of the existing buildings into highly energy efficient and decarbonised buildings [2]. Despite all these EU policies and efforts to replace these non-efficient heating systems, the main challenge is price comparison of different solutions and their efficiency in retrofitting of the heating old systems together with the lack of information about the functioning of those old systems [1]. Thus, the development of an easy to install heating system in retrofitting with low exergy heat supply is a significant contribution to a sustainable solution in minimizing energy resources depletion and environmental emission. Furthermore, efficient system control of these easy to install heating systems, hybrids combinations solution for retrofitting building could be a sustainable solution for the preservation of the existing building. The main objective of this work was to design an easy to install hybrid low-temperature floor heating system in retrofitting buildings and compare its results on energy performance, thermal comfort and indoor air quality with other conventional heating mainly used in the Mediterranean climate. This study was performed in two existing radiators heated buildings located in Sant Cugat del vallès in Catalonia, Spain.The results showed that the hybrid low-temperature heating system has the highest energy performance and energy saving of 48 % and 52% compared to that of existing radiator heating and all air heating, respectively. However, hybrid low-temperature floor heating showed a slow heating response, and consequently, it showed lower operative temperature compared to others even though it was within the recommended standards limits. The hybrid low-temperature heating system with demand-controlled ventilation also showed a better indoor air quality, while as existing radiator with its natural ventilation showed the worst indoor air quality. All three compared heating systems showed a better coefficient of performance with low-temperature heat supply and were able to operate with low-temperature heat supply. / Mer än 50% av EU:s årliga energibehov spenderas på värme- och kylsystem där de flesta av deras källor genereras från icke-förnybart fossilt bränsle [1]. Dessutom värms hälften av EU:s byggnader upp med en ineffektiv panna med cirka 60% eller mindre effektivitet [1]. EU:s rapport från 1990 till 2007 avslöjade att bränsleförbränning och flyktiga utsläpp bidrar till cirka 79% av de totala utsläppen av växthusgaser i koldioxidekvivalenter [1]. EU:s och EBPD:s långsiktiga renoveringsstrategi är att förbättra energiprestanda för alla bostäder och andra byggnader i dess medlemsländer genom att stödja renovering av befintliga byggnader till mycket energieffektiva byggnader [2].Trots alla dessa EU-policyer och ansträngningar för att ersätta dessa ineffektiva värmesystem, är den största utmaningen prisjämförelse av olika lösningar och deras effektivitet i renovering av de gamla värmesystemen tillsammans med bristen på information om hur de gamla systemen fungerar [1]. Därför är utvecklingen av ett installationsenkelt värmesystem med låg värmeförsörjning av exergi ett viktigt bidrag till en hållbar lösning för att minimera energiresurser och miljöutsläpp. Dessutom kan effektiv systemkontroll av dessa värmesystem med olika kombinationslösningar för renovering av byggnaden vara en hållbar lösning för att bevara den befintliga byggnaden.Huvudsyftet med detta arbete var att utforma ett lågtemperaturgolvvärmesystem att använda vid renovering av byggnader och jämföra dess resultat på energiprestanda, termisk komfort och inomhusluftkvalitet med annan konventionell uppvärmning som huvudsakligen används i medelhavsklimat. Denna studie utfördes i två befintliga radiatoruppvärmda byggnadet i Sant Cugat del vallès i Katalonien, Spanien. Resultaten visade att hybridsystemet med låg temperatur har den högsta energiprestandan och energibesparingen på 48% och 52% för den befintliga radiatorvärme respektive luftvärme. Emellertid visade lågtemperaturgolvvärme ett långsamt uppvärmningssvar, och följaktligen visade det lägre driftstemperatur jämfört med de andra systemen trots att det låg inom de rekommenderade standardgränserna. Lågtemperaturvärmesystem med efterfrågningsstyrd ventilation visade också en bättre inomhusluftkvalitet, medan befintliga radiatorer med sin naturliga ventilation visade den sämsta inomhusluftkvaliteten. Alla tre jämförda värmesystemen visade bättre prestanda med lågtemperaturvärmeförsörjning och kunde fungera med lågtemperaturvärmeförsörjning.
104

Fältmätningar av termisk komfort och luftkvalitet i kontorsrum i äldre temperaturreglerad stenbyggnad

Boström, Hanna, Lindelöw, Hanna January 2022 (has links)
Personal på Högskolan i Gävle tycks periodvis uppleva dålig komfort ikontorsrummen på södersidan i skolans gamla kasernbyggnader. En undersökninggjordes därför på högskolan i april månad i tre kontor, ett med fönsterhuvudsakligen i norrläge och två med fönster huvudsakligen i söderläge. Syftet varatt kartlägga den termiska komforten och luftkvaliteten i de olika väderstrecken ochjämföra med gällande rekommendationer, bland annat genom att beräkna PMV vidolika tillfällen. Vidare undersöktes potentiella samband mellan ute- och inneklimatsamt tunna gardiners inverkan på termostat, värmeflöde och komfort. Den undersökta byggnaden är en äldre stenbyggnad med ovanligt välisoleradefönster och termostatstyrda, vätskeburna radiatorer. Byggnaden har FTX-ventilationmed ett till- och ett överluftsdon i varje kontorsrum. Mätningarna utfördes meddataloggrar som mätte lufttemperatur, relativ luftfuktighet och koldioxidhalt. I tvåav rummen mättes även globtemperatur. Utöver det mättes lufthastighet på tre olikahöjder i två av rummen samt ventilationsflödet i samtliga rum. Resultatet visade att inomhus- och utomhustemperatur har en relativt högkorrelation. Relativa luftfuktigheten var nästan alltid högst i norrläge, men i samtligarum var den låg – lägre än vad som rekommenderas i riktlinjerna. Soligt väderpåverkade temperatur och relativ luftfuktighet inomhus mest av alla vädervariabler,men personnärvaro och ventilation påverkade mer än utomhusklimatet. Kontor isöderläge hade som förväntat högre temperatur än i norrläge, och översteg deriktlinjer som finns för temperatur i kontor. Som följd av detta blev PMV högre isöderläge, tillfälligt högre än komfortgränsen 0,5, med ett högsta värde på 1,41. Kontoret i norrläge höll sig vid de undersökta tillfällena inom intervallet föraccepterat PMV med ett lägsta värde på -0,35. Detta tyder på att värme i söderlägeär ett större problem än kyla i norrläge. Lufthastigheterna blev låga i bådaväderstrecken. Ventilationsflödena visade sig vara 2/3 av det projekterade värdet,men ändå låg koldioxidhalten på en acceptabel nivå enligt riktlinjer. Gardiner påverkade komforten mer i söderläge än norrläge, men påverkade intetillräckligt mycket för att komma ner i en acceptabel komfortnivå vilket kan bero påatt de var av mycket tunt material. Det var svårt att se tydlig gardinpåverkan påtermostaten, men fråndragna gardiner kan leda till att termostaten reagerar påtemperaturökningar i ett rum snabbare. Däremot påverkades värmeflödet tydligaregenom fönstret av gardinerna. Skillnaden i värmeflödet vid för- och fråndragnagardiner blev 4,1 W. / Employees at University of Gävle seem to periodically experience suboptimalcomfort in south facing offices in the school’s old barrack buildings. Therefore, acase study was conducted in April in three offices, one facing north and two facingsouth. The aim of the study was to map the thermal comfort and air quality in thedifferent directions and compare these to the existing recommendations, includingcalculating PMV at different times. A potential correlation between out- and indoorclimate was also examined, as well as the effect of thin curtains on the thermostat, heat flux and comfort. The University of Gävle is an old brick building with unusually well insulatingwindows and thermostatically regulated, waterborne radiators. The building hasmechanical ventilation with heat recovery, and each office has one supply and oneover-air diffuser. The measurements were made with data loggers that measured airtemperature, relative humidity and carbon dioxide. The globe temperature was alsomeasured in two of the rooms. The air velocity on three heights was measured aswell in two of the offices and the ventilation flow was measured in all the rooms. The result showed that indoor- and outdoor temperature have a relatively highcorrelation. The relative humidity was almost always higher in the north facingoffice, but in all the rooms it was low – lower than the recommended guidelines.Sunny weather affected the indoor temperature and relative humidity the most of allthe weather variables, but presence of people and ventilation affected more than theoutdoor climate. South facing offices had as expected a higher temperature thannorth facing ones, and exceeded the guidelines concerning temperatures in offices.Due to that the PMV was higher in the south facing office, temporarily exceedingthe comfort limit of 0,5, with a maximum value of 1,41. The north facing office waswithin the limits during the measurements and had a minimum value of -0,35. Thisindicates that heat in the south facing office is more of a problem than coldness inthe north facing office. The air velocities were low in both directions of thebuilding. The ventilation flow turned out to be 2/3 of the intended value, but thecarbon dioxide content was still acceptable according to guidelines. Curtains influenced the comfort more in the south facing office than in the northfacing office, but they didn’t influence enough to get to an acceptable comfort level,which may be because of the very thin material. It was difficult to see a distinctinfluence from the curtains on the thermostat, but using no curtains could lead tothe thermostat responding faster to increases in temperature in a room. However,the heat flow through the window was influenced more distinctly by the curtains.The difference in heat flow when using curtains compared to no curtains was 4,1 W.
105

''Att uppnå fullständig komfort är omöjligt'' : En kvalitativ studie om revisorers upplevelser av obehag och komfort vid granskningen av immateriella tillgångar / ''Achieving complete comfort is impossible'' : A qualitative study on auditor's experiences of discomfort and comfort in the audit of intangible assets

Shala, Loreta January 2023 (has links)
Bakgrund och problem: Under de senaste decennierna har andelen immateriella tillgångar i företagens balansräkningar ökat markant. Det har dock inte skett någon väsentlig förändring i den internationella standarden IAS 38, som fastställer principer för redovisning av immateriella tillgångar. Detta har skapat osäkerhet och utmaningar i tillämpningen av standarden och har blivit kärnan i det som nu kallas "2000-talets redovisningsutmaning". Tidigare studier har funnit att företag med en hög andel immateriella tillgångar också betalar högre revisionsarvoden, vilket kan hänföras till att revisorer upplever obehag vid revision av dessa tillgångar på grund av olika risker förknippade med dem. Det är dock relativt outforskat vilket eller vilka specifika obehag som svenska revisorer upplever och hur de eliminerar dem för att uppnå ett tillstånd av komfort. Syfte: Syftet med studien är att bidra till fördjupad kunskap om revisorns bedömning av immateriella tillgångar. Ur detta syfte kommer det att ligga fokuspå hur komfort skapas och uppnås samt vad som eventuellt skapar en känsla av obehag och hur detta kan elimineras. Metod: Denna studie har genomförts med kvalitativ metod och innefattar en deduktiv forskningsansats där empirin har samlats in genom semi strukturerade intervjuer med åtta auktoriserade revisorer på svenska revisionsbyråer. Slutsats: Studien påvisar att en revisors erfarenhet och längden på karriären inte är tillräckligt för att eliminera de obehag som finns vid bedömningen av immateriella tillgångar. Resultaten tyder på att revisorer upplever olika typer av obehag i varje fas av revisionsprocessen och är beroende av andra aktörer för att kunna eliminera obehagen och uppnå ett stadie av komfort. Det är framför allt tre aktörer som är av stor vikt för att bidra till skapandet av komfort och dessa är en överordnad person inom revisionsbyrån, ekonomichefen på det reviderade företaget och specialister. / Background and problem: During the past decades, the proportion of intangible assets has significantly increased on companies' balance sheets. At the same time, there hasn't been any significant change in the international standard IAS 38, which establishes principles for the accounting of intangible assets. This has created uncertainty and challenges in the application of the standard and has become the core of what is known as the '21st-century accounting challenge.' Previous studies have found that companies with a high proportion of intangible assets also pay higher audit fees, which can be explained by auditors experiencing discomfort in auditing these assets due to various risks associated with them. However, it is relatively unexplored what specific discomfort Swedish auditors experience and how they eliminate them to achieve a state of comfort. Purpose: The purpose of the study is to contribute to a deeper understanding of the auditor's assessment of intangible assets. Within this purpose, the focus will be on how comfort is created and achieved, as well as what potentially creates asense of discomfort and how it can be eliminated. Method: This study has been conducted using a qualitative method and involves a deductive research approach, where data collection was carried out through semi-structured interviews with eight certified auditors from Swedish auditing firms. Conclusion: This study demonstrates that an auditor's experience and length of career are not sufficient to eliminate the discomfort associated with the assessment of intangible assets. The results suggest that auditors experience different types of discomfort in each phase of the audit process and rely on other actors to eliminate the discomfort and achieve a state of comfort. Three actors, in particular, are crucial in contributing to the creation of comfort, namely a superior within the auditing firm, the chief financial officer of the audited company and specialists.
106

Komfort- och energianalys vid installation av markiser på Högskolans i Gävle glasfasader : Mätningar och IDA ICE-simuleringar

Höglund, Marcus, Stenås, Anton January 2021 (has links)
Högskolan i Gävle planerar att installera solavskärmande markiser på entréhallarnas sydliga glasade fasader. Sedan uppbyggnad har entrébyggnaden som inkluderar ”Rävhallen” och ”Fårhallen” lidit av bristfällig termisk inomhuskomfort på grund av värmeläckage och överhettning orsakade av fasadernas fönsterpartier. Detta examensarbete gjordes i syfte att via mätningar undersöka den termiska inomhuskomforten i Högskolans i Gävle entréhallar. Arbetet syftade också till att årssimulera och analysera årlig energiförbrukning och termisk inomhuskomfort innan och efter installationen av solavskärmande markiser på byggnadens glasfasader, i simuleringsprogrammet IDA ICE. En komfortundersökning gjordes genom att mäta termisk komfort och inomhustemperaruter under två tillfällen i april månad. Mätningarna gjordes under en molnig dag och en solig dag vid samma utomhustemperatur, för att undersöka solinstrålningens inverkan på byggnadens termiska komfort och inomhustemperaturer. Komfortundersökningen visade att den termiska komforten i Rävhallen och Fårhallen var undermålig då överhettning uppstår vid hög solinstrålning. Nödvändiga data inför modellering och simulering insamlades genom observationer, uppskattning, beräkningar och samtal med drifttekniker vid Akademiska hus. Efter datainsamlingen konstruerades en modell i simuleringsprogrammet IDA ICE. Innan simulering validerades modellen med hjälp av tidigare uppmätta temperaturer under april månad. Sedan simulerades byggnadens energiförbrukning och termiska inomhuskomfort över ett helt år, utan markiser, och därefter med markiser. Resultatet visade att den termiska komforten förbättrades markant vid installation av markiser. Höga topptemperaturer som tidigare förekom i byggnaden minskade eftersom markiserna reducerade solinstrålningen genom fasadens fönsterpartier. Det totala årliga energibehovet ökade dock från 605 MWh till 635 MWh. Det årliga energibehovet för kyla minskade något från 3,4 MWh till 3,2 MWh. Att energiförbrukningen ökade berodde på att markiserna reducerade nyttig gratisvärme från solinstrålningen, särskilt under uppvärmningssäsong. För vidare forskning föreslås en mer effektiv styrteknik av markiserna och en mer detaljrik simuleringsmodell för att få tillförlitligare resultat. Vid tillämpning av bättre anpassad styrning av markiserna bedöms energibesparingspotentialen bli större. Slutsatsen drogs att markiser kan förbättra den termiska inomhuskomforten avsevärt, men att energiförbrukningen kan komma att öka beroende på styrteknik. / The University of Gävle plans to install solar shading awnings on the southern glass facades of the main entrances. Since construction, the main entrances Rävhallen and Fårhallen have suffered from poor thermal indoor comfort due to heat leakage and overheating due to the windows on the facades. This thesis was done in order to map and investigate the thermal indoor comfort in the University of Gävle's main entrances. The work also aimed to simulate and analyze annual energy consumption and thermal indoor comfort before and after the installation of solar shading awnings on the building's glass facades, in the simulation program IDA ICE. A comfort survey was conducted by measuring thermal comfort and indoor temperature ranges on two occasions in April. The measurements were made during a cloudy day and a sunny day at the same outdoor temperature, to investigate the effect of solar radiation on the building's thermal comfort and indoor temperatures. The comfort survey showed that the thermal comfort in Rävhallen and Fårhallen was insufficient as overheating occurs at high solar radiation. Data necessary for modeling and simulation was collected through observations, estimates, and dialogs with operating technicians from Akademiska hus. After data collection, a model was constructed in the simulation program IDA ICE. Before simulation, the model was validated using previously measured temperatures during the month of April. Then the building's energy consumption and thermal indoor comfort were simulated over a whole year, without awnings, and with awnings. The results showed that the thermal comfort was significantly improved by the awnings installations. High peak temperatures that previously occurred in the building decreased because of the reduced solar radiation through the glass facade. The total annual energy demand increased from 605 MWh to 635 MWh. However, the annual energy demand for cooling decreased from 3,4 MWh to 3,2 MWh. The increase in energy consumption was due to the awnings reducing useful heat from solar radiation, especially during the heating season. Prior to further research, a more efficient control technique of the awnings and a more detailed model to improve the simulation results are proposed. When applying better adapted control of the awnings, the energy saving potential is considered to be greater. It was concluded that awnings can significantly improve indoor thermal comfort, but that energy consumption may increase depending on control technology.
107

Portable Heat Kit : Explorative research on application of heat as a comfort material in day

Damitha Gunawardena, Suresh January 2022 (has links)
Heat is an essential aspect of personal comfort. However, designing for heat as a comfort material is difficult due to the subjective nature of materials in combination with differing human perceptions and preferences. This paper presents the results of an explorative design project, where a heat kit consisting of three design probes was developed through self-exploration and participatory design with five participants. Field studies with this heat kit enabled the participants to interact with heat as a comfort material in their day-to-day lives. This allowed exploration of the contexts where heat is considered a comfort material, use cases stemming from these contexts, and usability considerations in designing with heat as a comfort material. As a result, two significant paradigms of using heat for comfort emerged: discomfort-avoidance behavior and comfort-seeking behavior. In addition, the degree of flexibility for users, importance of material with differing use cases, controllability of heat, and comfort in social interactions emerged as key design considerations when developing artifacts with heat as a comfort material. / Värme är en viktig aspekt när det gäller personliga bekvämligheter. Att skapa en design där värme är ett bekvämlighetsmaterial är dock svårt på grund av materialets subjektiva natur och människors multipla preferenser. Denna artikel presenterar resultaten av ett utforskande designprojekt, där ett värmekit bestående av tre designsonder utvecklades genom självutforskning och fem deltagares design. Fältstudier med detta värmekit gjorde det möjligt för deltagarna att interagera med värme som ett bekvämlighetsmaterial i deras dagliga liv, vilket gjorde det möjligt att utforska de sammanhang där värme anses vara ett bekvämlighetsmaterial, användingsfall som kommer från dessa kontext samt omständigheter för användaren som kommer från att designa efter värme som ett bekvämlighetsmaterial. Som ett resultat uppstod två betydande paradigm för att använda värme för komfort: beteende som undviker obehag och beteende som söker komfort. Dessutom framträdde graden av flexibilitet för användarna, vikten av material med olika användningsfall, reglerbarhet av värme och komfort i sociala interaktioner som viktiga designöverväganden vid utveckling av artefakter med värme som komfortmaterial.
108

Optimering av dubbelspaltigt värmefönster / Optimization of double slotted heat exchange window

Gil Castro, Roberson Manuel André, Henriksson, Claes Evald January 2020 (has links)
Utvecklad för att bibehålla termisk komfort och minska exergianvändningen, Free Heat Exchange Window [FHEW] är en fönsterdesign som är tänkt att ersätta konventionella värmesystem i bostäder och kontorsbyggnader. Baserat på dubbelspaltkonceptet kommer fönstret utgöra en värmekälla under kalla vinterdagar och en värmesänka under varmare sommardagar. För att värdera huruvida teknologin kan bibehålla tillräcklig termisk komfort och avgöra dess optimala parameterkonfiguration utifrån byggnadens effektbehov skapas två olika modeller. En grundar sig på en datorsimulering av en lägenhet i COMSOL Multiphysics och den andra är en analytisk metod för beräkning av energibalanser i MATLAB. Resultaten från båda modellerna påvisade att hög inströmningstemperatur och låg inströmningshastighet är att föredra för minimering av effektbehovet. Å andra sidan ger en låg inströmnings temperatur och hög strömningshastighet en upphov till högre termisk komfort. Valet av den isolerande gasen som används i mittersta gas-spalten bedöms ha låg inverkan på prestandan, särskilt för höga strömningshastigheter. En alternativ modell med den isolerande gas-spalten omplacerad närmast utomhuset skulle kunna framföra bättre användning av den isolerande gas-spaltens funktion. Datorsimuleringen jämförs avslutningsvis med en ekvivalent lägenhetsmodell med enkelspaltiga fönster och element som värmekälla. Denna modell kräver lägre effekt, men är samtidigt mindre flexibel och inducerar en lägre termisk komfort. Datorsimuleringen rekommenderas på grund av dess antaganden och i vissa fall orimliga resultat endast som jämförelse med andra liknande modellen, snarare än verkliga data. / Developed to maintain thermal comfort and reduce exergy usage, Free Heat Exchange Window [FHEW] is a modern window design aimed to replace current heat systems in homes and office buildings. Based on the double slot concept, the window can be used as a heat source during cold winter days and heat sink during warmer summer days. To evaluate if the technology is viable to maintain thermal comfort and determine its optimal parameters with respect to energy efficiency, two different models will be made. One is based on computer simulations in COMSOL Multiphysics and one is based on analytical equations in MATLAB. The results from both models proved that a higher inflow temperature and a lower flow rate was prefered to minimize power demand. On the contrary, a lower inflow temperature and a higher flow rate is preferred to achieve the best thermal comfort. The differences between the choice of insulation gas gave unnoticeable deviation for indoor heat exchange for high flow rates. An alternative window model could reposition the insulation gas-gap to be between the whole system and the outdoors environment, instead of having it installed between the flowing air-gaps, for better use of the low thermal conductivity. The computer simulation is finally compared with an equivalent model using regular single slot windows and radiators as heaters. This model requires less energy but is less flexible and induces a less desirable thermal comfort. The computer simulation is due to its assumptions and in some instances implausible results only recommended to be compared to similar models, rather than real data.
109

INOMHUSKLIMATETS OLIKA FAKTORERS PÅVERKAN PÅ MÄNNISKANS VÄLBEFINNANDE : - En jämförelse mellan två förskolors inomhusklimat / HE IMPACT OF VARIOUS FACTORS OF INDOOR CLIMATE ON HUMAN WELLBEING : - A comparison between two preschool’s indoor climate

Gustavsson, Jenny, Högstedt, Oscar January 2024 (has links)
Människor spenderar idag över 90% av sin tid inomhus och inomhusklimatet spelar därför en viktig roll i personers hälsa och välbefinnande, större ju yngre personerna är. Syftet med den här rapporten har varit att undersöka och jämföra inomhusklimatet på två förskolor i Hallsbergs kommun, förskolan Äppellunden och Kompassen, med följande frågeställningar: - Hur upplevs förskolan Kompassens inomhusklimat i förhållande till mätningar av inomhusklimatet? - Hur upplevs förskolan Äppellundens inomhusklimat i förhållande till mätningar av inomhusklimatet? - Hur förhåller sig de två förskolornas upplevda inomhusklimat och mätningar av inomhusklimatet, vad gäller operativ temperatur, luftkvalitet, lufthastighet och fukt? Studien har pågått under en begränsad tid och har endast studerat rummen i förskolorna som barnen vistas i kontinuerligt. Studien tar inte i beaktning faktorer såsom ljud, ljus och lukt. Inomhusklimatet har studerats genom en enkät som skickats ut till alla pedagoger på de två förskolorna samt kompletterats med egna mätningar på luftkvalité och temperatur. De två förskolorna är i grunden väldigt olika. Äppellunden är en nybyggd förskola från 2019, medan Kompassen är en industrilokal från 1981 som år 2014 byggdes om till förskola. Inomhusklimatet påverkas av många olika faktorer som alla måste samverka. Här innefattas bland annat ventilationen, vars huvudsakliga funktion är att föra bort förorenad luft och tillföra ny luft. Inomhusklimatet ska även ha en behaglig temperatur, där kraven ställs utifrån den operativa temperaturen. Det ska heller inte vara varken för fuktig eller för torr luft inomhus och människan ska inte uppleva drag. För samtliga faktorer finns krav eller rekommendationer som bör följas för att upprätta ett bra inomhusklimat. Tidigare har bland annat projektet BETSI samt undersökningen ELIB utfört landsomfattande studier på inomhusklimatet. För att undersöka hur inomhusklimatet upplevs på förskolorna skickades en enkät om inomhusklimatet ut till pedagogerna. På samma förskolor mättes medelstrålningstemperaturen, lufttemperaturen, den relativa fuktigheten samt koldioxidhalten. Detta skedde i ett rum per avdelning och på fyra punkter i vardera rum. Även den operativa temperaturen beräknades. Över lag visade mätningarna att förskolorna har ett bra inomhusklimat, dock har de en torr inomhusluft. Tidigare undersökningar har visat att torr luft oftare blir ett större problem i stora hus. Detta gällde dock en studie om flerbostadshus, men vissa paralleller till förskolorna kan fortfarande dras. Från enkäten utlästes att pedagogerna främst hade problem med en varierande rumstemperatur på Äppellunden. Detta kan bero på att Äppellunden har ett ventilationssystem med ett varierande luftflöde. Kompassen besvärades främst av torr luft, en varierande rumstemperatur samt känslan av en instängd luft. Samtliga mätningar som utförts uppfyllde kraven och rekommendationerna som finns från myndigheter med undantag från en mätning på Kompassen. / People today spend more than 90% of their time indoors, making the indoor climate an important and significant part of their health and well-being, especially for younger people. The purpose of this report is to investigate and compare the indoor climate of two preschools in Hallsbergs Municipality, Äppellunden and Kompassen, with the following questions: - How is the indoor climate of Preschool Kompassen perceived in relation to measurements of the indoor climate? - How is the indoor climate of Preschool Äppellunden perceived in relation to measurements of the indoor climate? - How do the perceived indoor climate and measurements of indoor climate compare between the two preschools regarding operative temperature, air quality, air velocity and humidity? The study was conducted over a limited period and only examined the rooms in the preschool where the children are continuously present. The study does not consider factors such as noise, light, and smell. The indoor climate was studied through a survey sent to all educators at the two preschools and complemented by independent measurements of air quality and temperature. The two preschools are fundamentally very different Äppellunden is a newly built preschool from 2019, while Kompassen is an industrial building from 1981 that was converted to a preschool in 2014. Indoor climate is influenced by many different factors that all need to work together. This includes ventilation, whose main function is to remove polluted air and bring in fresh air. The indoor climate should also have a comfortable temperature, with requirements based on the operative temperature. The indoor air should not be too humid or too dry indoors, and people should not feel drafts. For all factors, there are requirements or guidelines that should be followed to establish a good indoor climate. Projects like BETSI and the ELIB survey have previously conducted nationwide studies on indoor climate. To investigate how the indoor climate is perceived at the preschools, a survey about the indoor climate was sent to the educators. In the same preschools, measurements of mean radiant temperature, air temperature, relative humidity, and carbon dioxide levels were taken, and the operative temperature calculated. This was done in one room per department and at four points in each room. Overall, the measurements showed that the preschools have a good indoor climate; however, they both have dry indoor air. Previous studies have shown that dry air often becomes a larger problem in big buildings. This was a study on multi-family houses, but some parallels to the preschools can still be drawn. From the survey, it was found that the educators mainly had problems with a varying room temperature at Äppellunden. This may be due to Äppellunden having a ventilation system with varying air flow. Kompassen mainly suffered from dry air, varying room temperature, and a feeling of stale air. All measurements performed met the requirements and recommendations from authorities, except for one measurement at Kompassen.
110

Experimental study of an intermittent ventilation system in high occupancy spaces

Kabanshi, Alan January 2017 (has links)
Spaces with high occupancy density like classrooms are challenging to ventilate and use a lot of energy to maintain comfort. Usually, a compromise is made between low energy use and good Indoor Environmental Quality (IEQ), of which poor IEQ has consequences for occupants’ health, productivity and comfort. Alternative strategies that incorporate elevated air speeds can reduce cooling energy demand and provide occupant’s comfort and productivity at higher operative temperatures. A ventilation strategy, Intermittent Air Jet Strategy (IAJS), which optimizes controlled intermittent airflow and creates non-uniform airflow and non-isothermal conditions, critical for sedentary operations at elevated temperatures, is proposed herein. The primary aim of the work was to investigate the potential of IAJS as a ventilation system in high occupancy spaces. Ventilation parameters such as air distribution, thermal comfort and indoor air quality are evaluated and the system is compared with a traditional system, specifically, mixing ventilation (MV). A 3-part research process was used: (1) Technical (objective) evaluation of IAJS in-comparison to MV and displacement ventilation (DV) systems. (2) An occupant response study to IAJS. (3) Estimation of the cooling effect under IAJS and its implications on energy use. All studies were conducted in controlled chambers. The results show that while MV and DV creates steady airflow conditions, IAJS has  cyclic airflow profiles which results in a sinusoidal temperature profile around occupants. Air distribution capability of IAJS is similar to MV, both having a generic local air quality index in the occupied zone. On the other hand, the systems overall air change rate was higher than a MV. Thermal comfort results suggest that IAJS generates comfortable thermal climate at higher operative temperatures compared to MV. Occupant responses to IAJS show an improved thermal sensation, air quality perception and acceptability of indoor environment at higher temperatures as compared to MV. A comparative study to estimate the cooling effect of IAJS shows that upper HVAC setpoint can be increased from 2.3 – 4.5 oC for a neutral thermal sensation compared to a MV. This implies a substantial energy saving potential on the ventilation system. In general, IAJS showed a potential for use as a ventilation system in classrooms while promising energy savings. / Lokaler där många människor vistas, som t.ex. klassrum, är ofta svåra att ventilera. Att upprätthålla en bra termisk komfort kräver en hög energianvändning. Vanligtvis blir det en kompromiss mellan låg energianvändning och bra kvalitet på inomhusmiljön (IEQ). Dålig IEQ får konsekvenser för människors hälsa, produktivitet och komfort. Alternativa ventilationsstrategier, som använder förhöjda lufthastigheter, kan minska kylbehovet och därmed energianvändningen. I denna avhandling utvärderas en ny ventilationsstrategi, Intermittenta luftstrålar (IAJS), där korta perioder med hög lufthastighet genererar en svalkande effekt, när rummets temperatur upplevs som för hög. Det primära syftet med arbetet var att undersöka potentialen hos IAJS som ett ventilationssystem för klassrum, där den termiska lasten ofta är hög. Strategin jämförs mot traditionella ventilationsprinciper som omblandande ventilation (MV) och deplacerande ventilation (DV). Parametrar som luftdistributionsindex, termisk komfort, luftkvalitet och energibesparing har utvärderats. Alla studier utfördes i klimatkammare. Resultaten visar att medan MV och DV skapar konstanta luftflödesförhållanden genererar IAJS cykliska hastighetsprofiler samt en sinusformad temperaturvariation i vistelsezonen. IAJS klarar att bibehålla ett bra termiskt klimat vid högre operativa temperaturer jämfört med MV. I en jämförelse med ett traditionellt HVAC-system visar beräkningar  att dess börvärde kan höjas från 2.3 till 4.5 °C med bibehållen termisk komfort. Detta indikerar en avsevärd energibesparingspotential vid användande av IAJS.

Page generated in 0.1076 seconds