• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 134
  • 28
  • 2
  • Tagged with
  • 164
  • 66
  • 44
  • 24
  • 21
  • 21
  • 20
  • 19
  • 17
  • 14
  • 14
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Undersökning av ljudnivåer på skolgårdar : - samt hur fasad och fönster dimensioneras med uppmätta värden

Gustafsson, Linda January 2009 (has links)
<p>This report is written on commission by WSP Acoustics. The report studies the outdoor sound levels on school yards in Stockholm. The questions given by the company to be answered was what are the actual sound levels at diffrent school yards with low traffic noise and how can you construct a facade element that reduces the sound level from the outside and meet the indoor requirements. Mesurements for four hours was done at eight schools set north and south of the city centre. The measurement period included one school break and one lunch break. The results of the measurements were that the equivalent and maximum sound level had small variations between the schools with some exceptions.The equivalent sound level was Leq 58-62 dB(A) and this shows a small variation. The school with the highest equivalent sound level of 67 dB was Maria skolan. This high level can be explained by more children on the school yard together at the same time etc. The maximum sound level was 85-89 dB(A), this if the level for Sofia skolan 82 dB was ignored. The level 85-89 dB(A) also shows a small variation. Calculations of the sound reduction index (R'w) for facade elements were also carried out for all the schools. The resulting sound reduction index for the whole facade was 34-41 dB. After assuming a 200 mm thick concrete facade for Sjöstadsskolan another calculation of building elements gives that the window have to reduce R'w 32 dB to meet the indoor requirements. In the future WSP Acoustics will use this report to choose building elements such as windows when building or rebuilding schools. It can also be used if any of the eight schools in this report needs a window changed to improve the acoustics.</p>
152

Undersökning av ljudnivåer på skolgårdar : - samt hur fasad och fönster dimensioneras med uppmätta värden

Gustafsson, Linda January 2009 (has links)
This report is written on commission by WSP Acoustics. The report studies the outdoor sound levels on school yards in Stockholm. The questions given by the company to be answered was what are the actual sound levels at diffrent school yards with low traffic noise and how can you construct a facade element that reduces the sound level from the outside and meet the indoor requirements. Mesurements for four hours was done at eight schools set north and south of the city centre. The measurement period included one school break and one lunch break. The results of the measurements were that the equivalent and maximum sound level had small variations between the schools with some exceptions.The equivalent sound level was Leq 58-62 dB(A) and this shows a small variation. The school with the highest equivalent sound level of 67 dB was Maria skolan. This high level can be explained by more children on the school yard together at the same time etc. The maximum sound level was 85-89 dB(A), this if the level for Sofia skolan 82 dB was ignored. The level 85-89 dB(A) also shows a small variation. Calculations of the sound reduction index (R'w) for facade elements were also carried out for all the schools. The resulting sound reduction index for the whole facade was 34-41 dB. After assuming a 200 mm thick concrete facade for Sjöstadsskolan another calculation of building elements gives that the window have to reduce R'w 32 dB to meet the indoor requirements. In the future WSP Acoustics will use this report to choose building elements such as windows when building or rebuilding schools. It can also be used if any of the eight schools in this report needs a window changed to improve the acoustics.
153

Engineering seismological studies and seismic design criteria for the Buller Region, South Island, New Zealand

Stafford, Peter James January 2006 (has links)
This thesis addresses two fundamental topics in Engineering Seismology; the application of Probabilistic Seismic Hazard Analysis (PSHA) methodology, and the estimation of measures of Strong Ground Motion. These two topics, while being related, are presented as separate sections. In the first section, state-of-the-art PSHA methodologies are applied to various sites in the Buller Region, South Island, New Zealand. These sites are deemed critical to the maintenance of economic stability in the region. A fault-source based seismicity model is developed for the region that is consistent with the governing tectonic loading, and seismic moment release of the region. In attempting to ensure this consistency the apparent anomaly between the rates of activity dictated by deformation throughout the Quaternary, and rates of activity dictated by observed seismicity is addressed. Individual fault source activity is determined following the application of a Bayesian Inference procedure in which observed earthquake events are attributed to causative faults in the study region. The activity of fault sources, in general, is assumed to be governed by bounded power law behaviour. An exception is made for the Alpine Fault which is modelled as a purely characteristic source. The calculation of rates of exceedance of various ground motion indices is made using a combination of Poissonian and time-dependent earthquake occurrence models. The various ground motion indices for which rates of exceedance are determined include peak ground acceleration, ordinates of 5% damped Spectral Acceleration, and Arias Intensity. The total hazard determined for each of these ground motion measures is decomposed using a four dimensional disaggregation procedure. From this disaggregation procedure, design earthquake scenarios are specified for the sites that are considered. The second part of the thesis is concerned with the estimation of ground motion measures that are more informative than the existing scalar measures that are available for use in New Zealand. Models are developed for the prediction of Fourier Amplitude Spectra (FAS) as well as Arias Intensity for use in the New Zealand environment. The FAS model can be used to generate ground motion time histories for use in structural and geotechnical analyses. Arias Intensity has been shown to be an important strong motion measure due to its positive correlation with damage in short period structures as well as its utility in predicting the onset of liquefaction and landslides. The models are based upon the analysis of a dataset of New Zealand Strong Motion records as well as supplementary near field records from major overseas events. While the two measures of ground motion intensity are strongly related, different methods have been adopted in order to develop the models. As part of the methodology used for the FAS model, Monte Carlo simulation coupled with a simple ray tracing procedure is employed to estimate source spectra from various New Zealand earthquakes and, consequently, a magnitude - corner-frequency relationship is obtained. In general, the parameters of the predictive equations are determined using the most state-of-the-art mixed effects regression procedures.
154

Mätning av besökares ljudtrycksdos under musikfestival / Measurements of sounds preasure dosage during music festivals

Dahlén, Vilhelm, Landsten, Kristian January 2009 (has links)
Folkets Hus och Parker gav under våren 2008 en förfrågan om att under sommaren uppmäta den ljudtrycksdos en normal festivaldeltagare tillskansar sig under ett festivalbesök. De mätningar som genomfördes skedde på tre olika festivaler, Hultsfredsfestivalen, Peace &amp; Love och Storsjöyran. Mätningarna skulle ske över hela festivalbesöket och inte endast innefatta mätningar av konserter, för att kunna ge en rättvisare bild av den ljudtrycksdos som en person kan tänkas utsättas för under en festival. De två av Socialstyrelsen uppsatta gränsvärdena som ska följas är att evenemanget ska hålla sig under ett medelvärde på max 100 dB(A)LEQ och dess toppvärde får vara högst 115 dB(A). I överlag kunde vi se att ljudnivåerna hölls relativt bra inom riktvärdena på de tre festivalerna. Resultaten för festivalerna var att mätningarna på Hultsfred gav ett ljudtrycksmedelvärde på 86,1 dB(A)LEQ, Peace &amp; Love 88,8 dB(A)LEQ och Storsjöyran 85,7 dB(A)LEQ. Detta kan jämföras med arbetsmiljöverkets uppsatta gräns på 85 dB(A) för daglig bullerexponering. Viss forskning tyder dock på att musik och buller inte kan likställas och att människor normalt kan utsättas för 5 dB högre ljudnivåer av musik än buller, vilket i så fall skulle innebära att den dagliga gränsen för musikexponering skulle ligga på 90 dB(A).
155

Utvärdering av standard EN 1793–6:2012 för att undersöka bullerskyddsskärmars effektivitet in-situ

Sjöberg, Andrea January 2018 (has links)
Bullerskyddsskärmar används för att reducera buller från väg- och spårtrafik. Syftet med examensarbetet var att utvärdera standard EN 1793–6:2012, en mätmetod för att undersöka bullerskyddsskärmars effektivitet in-situ med avseende på ljudisoleringen. I nuläget bestäms bullerskyddsskärmars effektivitet med laborationsmätningar i ett diffust ljudfält, som inte överensstämmer med det direkta ljudfält och den komplexitet som är in-situ. Till följd av det blir ofta laborationsmätningarna missvisande. Det finns även en okunskap kring håligheter/ läckage och hur det påverkar den akustiska prestandan, vilket gör att det emellanåt leder till brister i installationen av bullerskyddsskärmar och att enhetens ljudreducering inte stämmer överens med förväntningarna. Det finns således ett behov av att bestämma en bullerskyddsskärms befintliga prestanda in-situ för att säkerställa de krav som ställs i specifikationerna. EN 1793–6:2012 ansågs vara lämplig för ändamålet men fler mätningar behövs utföras för att kunna säkerställa resultaten och för att verifiera mätsystemet. Ljudisoleringen bestämdes som en funktion av frekvenser i tersband och var giltiga i frekvensområdet mellan 200 Hz till 5 kHz respektive 400 Hz till 5 kHz. De undersökta bullerskyddsskärmar var: en i laminerat och härdat glas med aluminiumpelare, en icke-homogen vegetationsskärm i stålram och en kombinerad bullerskyddsskärm i akrylglas med aluminiumprofiler. Resultaten jämfördes med laborationsmätningar och/eller simuleringar i Insul. Bullerskyddsskärmarna i glas gav högre värden på ljudisoleringen än i laborationsmätning, ett resultat som kan bero på skillnaderna mellan diffust ljudfält och direkt ljudfält. Komplexiteten i vegetationsskärmen gjorde resultaten svåra att analysera, men läckage förekom i de högre frekvenserna. Adrienne-fönstren behövde bli specifikt beräknade för samtliga impulssvar eftersom dimensionerna för bullerskyddsskärmarna inte överensstämde med vad som definieras i EN 1793–6:2012 för certifieringsändamål. I EN 1793–6:2012 omnämns inte heller markreflektion, som påverkar den filtrerade signalen. Vidare studier behövs för att filtrera bort dessa oönskade komponenter. / Road traffic noise devices, for example noise barriers, are used to reduce the noise from road traffic and trams. The purpose of this master thesis is to evaluate the standard EN 1793-6:2012, a test method for determining noise barriers efficiency in-situ. Currently, noise barriers efficiency is determined with laboratory measurements in a diffuse sound field, which does not reflect the direct sound field and the complexity that are in-situ. As a result, laboratory measurements are often misleading. Due to a lack of knowledge about leakage, there are sometimes defects caused in the installation of the noise barriers that adversely affect the acoustic properties. There is thus a need to determine the intrinsic parameters of a noise barrier in-situ to ensure the requirements set in the specifications. The new method described in EN 1793-6:2012 was considered useful for the purpose but it was found that more measurements need to be performed to ensure results and to verify the measurement system. The sound insulation was determined for three noise barriers where results are expressed as a function of frequency in one third octave band and were valid in the frequency range between 200 Hz to 5 kHz respective 400 Hz to 5 kHz. The noise barriers tested were: a barrier in laminated glass with metal posts, a non-homogeneous vegetation barrier in a steel frame and a combined barrier with acrylic glass and metal. The results were compared with laboratory measurements and/or simulations in Insul. The glass barriers showed higher values ​​of the sound insulation index than the laboratory measurements, perhaps due to the different sound fields. The complexity of the vegetation barrier made the results difficult to analyze, but leakage occurred in the higher frequencies. The Adrienne temporal windows were specifically calculated for all impulse responses, since the dimensions of the noise barriers differed from the one defined in EN 1793-6: 2012 for certification purposes. Also, in EN 1793-6: 2012, ground reflection, which affects the filtered signal, is not mentioned. Further studies are needed to filter out these unwanted components.
156

Attenuation AND awareness? : Designing a method for measuring accuracy and certainty of sound identification when wearing a HPD

Ahlberg, Markus January 2020 (has links)
Noise pollution is widespread in today’s society, from traffic to industrial sources, and many people are confined to unhealthy acoustic environments through their employment. When noise cannot be eliminated at the sound source, the protective measure is usually to equip the employee with hearing protection devices (HPDs), e.g. earmuffs, that attenuates the noise. Applying excessive attenuation can render the wearer disconnected from her acoustic environment and present risks and social isolation. HPDs using level-dependent function (LDF) uses ambient microphones together with a signal processing unit and internal loudspeakers to achieve attenuation flexibility – if ambient noise is low, the loudspeakers can amplify the sound to combat an excessive passive attenuation of the HPD, and if ambient noise is high this amplification is decreased to maintain healthy sound levels. Appropriate levels of attenuation allows the user to detect ambient sounds which contributes to the their situational awareness. Besides attenuating the sounds however, HPDs does change the spectral content of the sound which may complicate the ability to identify them. This thesis has focused on exploring the human ability to identify sounds, design a method for measuring this ability, implement it and evaluate its result and the method itself. The thesis has been conducted in collaboration with 3MTM PeltorTM and was intended to evaluate the effect of earmuffs with LDF on the ability to identify sounds in a process industry soundscape. The progression of the thesis was structured within the Double Diamond process, where literature reviews, benchmarking and workshops informed the research and resulted in a method design that was analyzed using a repeated measures ANOVA based on empirical data from 16 participants. Surprisingly, the results showed no statistically significant advantage from wearing a HPD using LDF, as opposed to no LDF, in the user accuracy or certainty in sound identification. The reasons for this are discussed with a focus on evaluating the usefulness of the designed method in future efforts to develop HPDs that afford reliable sound identification. / Bullerföroreningar är ett utbrett problem i dagens samhälle, från trafik till industriella källor, och många människor är låsta till en ohälsosam akustisk miljö via sin anställning. När buller inte kan elimineras vid ljudkällan är skyddsåtgärden vanligtvis att förse arbetstagaren med hörselskydd, exempelvis hörselkåpor, som dämpar bullret. Att använda en överdriven dämpning kan dock göra att användaren avskiljs helt från sin akustiska miljö och innebära risker samt social isolering. Hörselskydd utrustade med nivåberoende funktion (LDF) använder mikrofoner tillsammans med en signalbehandlingsenhet och interna högtalare för att uppnå flexibilitet i dämpningen – om omgivande buller är lågt kan högtalarna förstärka ljudet för att motverka en överdriven passiv dämpning erbjuden av hörselskyddet, om omgivande buller däremot är högt kan denna förstärkning minskas för att vidhålla sunda ljudnivåer. Lämpliga dämpningsnivåer gör att användaren kan upptäcka omgivande ljud som bidrar till deras situationsmedvetenhet. Förutom att dämpa ljuden så ändrar dock hörselskydd också det spektrala innehållet i ljudet vilket kan komplicera förmågan att identifiera ljuden. Denna masteruppsats har fokuserat på att utforska människans förmåga att identifiera ljud, utforma en metod för att mäta denna förmåga, implementera metoden och utvärdera dess resultat samt metoden i sig. Uppsatsen har genomförts i samarbete med 3MTM PeltorTM och var avsedd att utvärdera effekten av hörselkåpor, utrustade med LDF, på förmågan att identifiera ljud i ett ljudlandskap likt det i en processindustri. Projektet var strukturerad enligt Double Diamondprocessen, där litteraturstudier, benchmarking och workshops har informerat och väglett arbetet och resulterat i en metod som analyserats med hjälp av variansanalys baserat på empiriska data från 16 deltagare. Överraskande nog så visade resultaten ingen statistiskt signifikant fördel med att bära ett hörselskydd som är utrustat med LDF till skillnad från ett hörselskydd som saknar denna funktion, vad gäller användarens förmåga att korrekt identifiera ljud samt rapporterad säkerhet i svaren. Orsaker till detta diskuteras med fokus på att utvärdera användbarheten av den utformade metoden i framtida ansträngningar för att utveckla hörselskydd som erbjuder tillförlitlig ljudidentifiering.
157

Jämförelse mellan bullerreducerande beläggning och bullerskärm. : Ur ett kostnads- och tekniskt perspektiv. / Comparison between noise reducing pavement and noise barriers. : From a cost and technical perspective.

Cardenas, Pablo, Wall, Peter January 2013 (has links)
Den bullerreducerande beläggnigen har en porös struktur som förbättrar dräneringen och reducerar buller vid källan men egenskaperna orsakar ett snabbt slitage och portäppning. Detta medför att beläggningen måste omläggas och rengöras oftare än en konventionell beläggning som t.ex. ABS 16. Kritiken mot den bullerreducerande beläggningen riktar sig på de höga drift- och underhållskostnaderna, detta gör att många väghållaren satsar på bullerskärm som bulleråtgärd.  Syftet med arbetet är att jämföra bullerreducerande beläggning med bullerskärm, för att reda på vilken bulleråtgärd är mer kostnadseffektivt under 20 år. Ett teoriavsnitt kommer att förklara och beskriva på ett tekniskt sätt: väg, ljud och buller, bullerskärm och bullerreducerande beläggningar. Kostnadsjämförelsen mellan bulleråtgärderna omfattar investering, drift och underhåll. Den fördjupar sig på en befintlig sträcka vid Gamla Enskede i Nynäsvägen, där det sedan 2012 finns bullerskärmar. De riktiga priserna av skärmarna ställs mot priserna för en eventuell bullerreducerande beläggning i sträckan. Priserna, antal omläggningar och bullerreducerande förlusten per år för den bullerreducerande beläggningen blev antagna genom beräkningar utifrån verkliga sträckor. Med hjälp av kalkyler och diagram kunde det noteras att bullerskärmarna är dyrare än bullerreducerande beläggningen. Förklaring av kostnadsresultat medföljs av rekommendationer som anses vara relevanta för att ha i åtanke för framtida val av bullerreducerande åtgärder. / Noise reducing pavement has a porous structure that improves drainage and reduces traffic noise but these propitious qualities causes’ problems such as rapid wear and pore clogging. This means that the pavement must be repaved and cleaned more frequently than a conventional pavement such as ABS 16. Criticism of the noise reducing pavement has been raised and has to do with the high operating and maintenance costs, this result in more invests in noise barriers instead. The purpose with this review is to compare noise reducing pavement with noise barriers, in order to determine which noise provision is more cost effective during a period of 20 years.  There will be a theory chapter were it will be explain and describe in a technical method: Road, sound and noise, noise barriers and noise-reducing pavement. Cost comparison of noise provisions includes investment-, operation- and maintenance cost. This review immerses on an existing road at Gamla Enskede in Nynäsvägen, which since 2012 has noise barriers. The actual prices of the noise barriers in Gamla Enskede will be compared to a possible noise reducing pavement. Prices, quantity of pavement replacement and noise loss per year for the noise reducing pavement was presumed by calculations based on actual distances with noise reducing pavement. Observation of our calculations and charts reveals that noise barriers are more expensive than noise reducing pavement.  Explanations of cost results are accompanied by recommendations that are considered relevant to have in mind for future choices of noise reduction provisions.
158

BULLERPROBLEMATIK I BOSTADSOMRÅDE VID NÄRLIGGANDE MOTORVÄG : Södra Källtorp i Västerås

Dusky, Karez, Ahmed, Dania January 2022 (has links)
Purpose: This degree project has investigated the problems Södra Källtorp has with noise due to the nearby highway E18. The purpose of this work is to investigate whether Södra Källtorp meets the guideline values and also whether the implemented noise protection measures in the neighbourhood have caused a change regarding the noise level. Method: The method for carrying out this degree project consisted of a literature study and a case study. The case study was carried out through own measurements and calculations. Four measuring points were chosen. The first two are located in Södra Källtorp and are covered by the noise protection, while the last two are not covered by any noise protection and are located in Råby. Based on the measurement results, the daily equivalent sound level was calculated based on the annual average daily traffic for each measurement point. In addition, interviews were held in order to get a picture of the noise experience among the residents in the neighbourhood. Results: According to the measurement results, the daily equivalent sound level was 55 dBA and the daily maximum sound level 61 dBA for measuring point M1. For measuring point M2, the daily equivalent sound level was 46 dBA while the daily maximum sound level was 53 dBA. Measuring point U1 had a higher noise level than measuring point M1 and measuring point U2 had a higher noise level than measuring point M2. Conclusions: Conclusions that can be drawn are that the noise protection measures have made a change regarding the noise level in Södra Källtorp and that the noise levels in Södra Källtorp do not exceed the guideline values. However, most noise levels that occur in the neighbourhood are not approved according to WHO. More noise protection measures may need to be taken in the future in order to meet WHO’s recommendations.
159

Röststyrning i industriella miljöer : En undersökning av ordfelsfrekvens för olika kombinationer mellan modellarkitekturer, kommandon och brusreduceringstekniker / Voice command in industrial environments : An investigation of Word Error Rate for different combinations of model architectures, commands and noise reduction techniques

Eriksson, Ulrika, Hultström, Vilma January 2024 (has links)
Röststyrning som användargränssnitt kan erbjuda flera fördelar jämfört med mer traditionella styrmetoder. Det saknas dock färdiga lösningar för specifika industriella miljöer, vilka ställer särskilda krav på att korta kommandon tolkas korrekt i olika grad av buller och med begränsad eller ingen internetuppkoppling. Detta arbete ämnade undersöka potentialen för röststyrning i industriella miljöer. Ett koncepttest genomfördes där ordfelsfrekvens (på engelska Word Error Rate eller kortare WER) användes för att utvärdera träffsäkerheten för olika kombinationer av taligenkänningsarkitekturer, brusreduceringstekniker samt kommandolängder i verkliga bullriga miljöer. Undersökningen tog dessutom hänsyn till Lombard-effekten.  Resultaten visar att det för samtliga testade miljöer finns god potential för röststyrning med avseende på träffsäkerheten. Framför allt visade DeepSpeech, en djupinlärd taligenkänningsmodell med rekurrent lagerstruktur, kompletterad med domänspecifika språkmodeller och en riktad kardioid-mikrofon en ordfelsfrekvens på noll procent i vissa scenarier och sällan över fem procent. Resultaten visar även att utformningen av kommandon påverkar ordfelsfrekvensen.  För en verklig implementation i industriell miljö behövs ytterligare studier om säkerhetslösningar, inkluderande autentisering och hantering av risker med falskt positivt tolkade kommandon. / Voice command as a user interface can offer several advantages over more traditional control methods. However, there is a lack of ready-made solutions for specific industrial environments, which place particular demands on short commands being interpreted correctly in varying degrees of noise and with limited or no internet connection. This work aimed to investigate the potential for voice command in industrial environments. A proof of concept was conducted where Word Error Rate (WER) was used to evaluate the accuracy of various combinations of speech recognition architectures, noise reduction techniques, and command lengths in authentic noisy environments. The investigation also took into account the Lombard effect.  The results indicate that for all tested environments there is good potential for voice command with regard to accuracy. In particular, DeepSpeech, a deep-learned speech recognition model with recurrent layer structure, complemented with domain-specific language models and a directional cardioid microphone, showed WER values of zero percent in certain scenarios and rarely above five percent. The results also demonstrate that the design of commands influences WER. For a real implementation in an industrial environment, further studies are needed on security solutions, including authentication and management of risks with false positive interpreted commands.
160

Medarbetares inställning till öppna kontorslandskap : En kvalitativ studie på en kundserviceavdelning / Employees´ attitude toward open office landscapes : A qualitative study in a customer service department

Götenstedt Hürbi, Arka, Brandt, Anna January 2024 (has links)
På grund av fördelar som bland annat flexibilitet, kostnadsbesparingar, och ökat samarbete mellan anställda har konceptet öppna kontorslandskap blivit en trend över hela världen. Flera studier har dock påvisat konceptets nackdelar där anställda och organisationer i helhet påverkas negativt, men ändå fortsätter organisationer att omvandla sina cellkontor till öppna kontorslandskap. Vissa verkar tycka om öppna kontorslandskap medan andra är mer negativt inställda. Denna uppsats har i syfte att undersöka vad medarbetare tycker om öppna kontorslandskap. Undersökningen tog plats på en kundserviceavdelning på ett pappersföretag. Åtta respondenter intervjuades då en kvalitativ studie utfördes. Vi har använt oss av bekvämlighetsurval och till viss del strategiskt urval, då vi hade en bekant som arbetade i det öppna kontorslandskapet på pappersföretaget som kunde förse oss med respondenter av intresse för studien. Relevanta begrepp och teorier presenteras i teoriavsnittet, för att förse läsaren med information och kunskap inom ämnet. Dessa teorier används även för att utforma intervjuguiden och hitta teman i det insamlade materialet från intervjuerna. Dessa teman kunde vi även använda oss av när vi analyserade materialet. Resultatet visade att inställningen till öppna kontorslandskap är högst individuell. Även om hälften av respondenterna var mer positiva och den andra hälften var mer negativa, fann vi att det var individuella skillnader i varför de var positivt eller negativt inställda. De anställdas inställning grundar sig i tidigare erfarenheter av andra kontorstyper, samt faktorer på arbetsplatsen såsom ljud/buller, ljusförhållanden, och luftkvaliteten. Unika fynd i studien var tystnaden i det öppna kontorslandskapet och hur detta påverkade de anställda. Utmärkande med just denna studie är att de flesta ljudkällorna som orsakade buller återfanns utanför det öppna kontorslandskapet.

Page generated in 0.0533 seconds