• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 13
  • Tagged with
  • 39
  • 39
  • 27
  • 24
  • 21
  • 20
  • 13
  • 13
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Klimatanpassning av bostadshus : En undersökning om kraven på klimatskalet måste anpassas för att behålla god termisk komfort i framtida klimat

Hall, Leo, Lövgren, Sofia January 2023 (has links)
Med hänsyn till förhöjda temperaturer, som i framtiden kan uppstå till följd av klimatförändringar, finns det ett behov av att undersöka energieffektiviteten och energiförbrukningen i byggnader. En möjlig åtgärd, för att motverka effekten av de förhöjda temperaturerna, kan vara att anpassa kraven som BBR ställer på bland annat U-värde och andra faktorer som påverkar inomhusklimatet. Studien undersöker om det finns ett behov av att klimatanpassa byggnaders klimatskal och tillhörande krav. Det har undersökts om behovet av att anpassa BBR:s krav på U-värden, energiprestanda och inomhusklimat, för att motverka påverkan av klimatförändringar, är aktuellt. Målet med studien är att undersöka och analysera om det är nödvändigt att anpassa kraven som BBR ställer på byggnader och därifrån utvärdera och se vilka metoder och designlösningar som skulle fungera som åtgärder till problemet. Resultatet av studien påvisade vikten av krav och hur de anpassar byggnaders energiprestanda. En möjlig anpassning av BBR:s krav är att minska de maximala tillåtna U-värdena för en byggnads ytterväggar, tak och fönster. Vid förhöjda temperaturer kommer antalet uppvärmningsdagar för byggnader att minska och därmed minskar även energiförbrukningen för uppvärmning. Däremot uppstår ett kylbehov där det i många fall kommer behövas installationer av kylsystem och ventilation. Plötsligt förändrade temperaturer kan även leda till problem i inomhusklimatet och därav är byggnadens tidskonstant av stor vikt för att hålla byggnader tåliga mot förändringar av utomhustemperatur. Metoder för att ta fram ett optimalt U-värde har diskuterats och det anses vara lämpligt att implementera dessa metoder i Sverige. U-värdet och primärenergitalet har en viktig koppling och har visat sig vara ytterst viktiga vid klimatanpassning av byggnader. En stor del av anpassningen beror på det lokala klimatet vilket kan komplicera processen för att göra en mer generell anpassning av kraven. Studien visade även att fönster står för 20–40% av byggnaders energiförluster men mot förmodan ger det inte en särskilt stor påverkan vid förhöjda temperaturer. Möjliga åtgärder som ger en minimal förbättring är bland annat smarta fönster och val av fönster med passande g-värde. Sammanfattningsvis kan anpassning av BBR:s krav på bland annat U-värde, inomhusklimat och energiprestanda vara en lämplig åtgärd för att minska energiförbrukningen i byggnader och därmed minska de negativa effekterna av klimatförändringar. En anpassning av kraven kan vara gynnsamt men är inte helt avgörande gällande byggnaders inomhusklimat. Arbetet betonar andra viktiga faktorer som byggnadens termiska tröghet och mängden isolering i byggnadselement, dessa har en större inverkan på inomhusklimatet i varmare utetemperaturer. / Considering the increased temperatures that may occur in the future as a result of climate change, there is a need to examine the energy efficiency and energy consumption of buildings. One possible measure to counteract the effects of increased temperatures could be to adjust the requirements set by BBR for factors such as U-value and indoor climate in order to meet the desired criteria. The study investigates whether there is a necessity to climate-adapt the building envelopes of structures. It has been explored whether the need to adapt BBR´s requirements for U-values, energy performance and indoor climate to mitigate the impact arising from climate change is pertinent. The objective of the study is to scrutinize and analyze the necessity of adapting the demands set by BBR, followed by an evaluation of the methods and design-solutions that could function as remedies to the problem. The findings of the study demonstrated the significance of requirements and how they can tailor the energy performance of buildings. One potential adjustment to BBR´s requirements is to reduce the maximum permissible U-values for a building's external walls, roof, and windows. In times of elevated temperatures, the number of heating-degree days for buildings will decrease, thus leading to a reduction in heating energy consumption. However, a cooling demand arises, often necessitating the installation of cooling systems and ventilation. Abrupt temperature changes can also result in indoor climate issues, underscoring the importance of the buildings time constant in maintaining resilience against alterations in outdoor temperatures. Methods for evaluating an optimal U-value have been deliberated upon and considered suitable for implementation in Sweden. The U-value and primary energy demand are closely interlinked and have proven to be crucial in the climate adaptation of buildings. A substantial portion of adaptation depends on the local climate, which can complicate the process of making a more generalized adjustment of requirements. The study also revealed that windows account for 20–40% of buildings energy losses, yet surprisingly, they do not exert a particularly significant influence during elevated temperatures. Potential measures yielding minimal improvement include smart windows and the selection of windows with appropriate solar heat gain coefficients (g-values). In conclusion, the adaptation of BBR's requirements, including U-value, indoor climate, and energy performance, can be a significant measure to reduce energy consumption in buildings and thereby alleviate the adverse effects of climate change. An adjustment of requirements may be beneficial but not entirely decisive concerning indoor climate. Instead, the work has emphasized other vital factors such as the building's thermal inertia and the amount of insulation in building elements.
32

Estimating Envelope Thermal Characteristics from Single Point in Time Thermal Images.

Alshatshati, Salahaldin Faraj January 2017 (has links)
No description available.
33

Fönsterbyte – alternativ för miljonprogrammets bostäder : Jämförande studie av energianvändning och CO2 påverkan

Rahi, Sonil January 2022 (has links)
In this comparative study were four alternative windows researched to find the most suitable ones for replacement when renovating the Million Programme housing. The methodology in the study involves a combination of methods, using interviews with companies and tenants, email correspondence with people who contributed to the study, and observation of a multi-family building built during the Million Programme. The result shows that all alternatives are ideal, and the only difference is the insulation performance and the energy-efficiency, which can be said to be minimal. CO2-emissions and thus climate impact will be lowered regardless of the choice of windows for replacement based on the alternatives investigated. The interviews show that the customer/client decides the choice of window, which the construction companies pass on to the window-suppliers. The existing windows in the observed building showed low quality of energy efficiency, comfort and thus high climate impact. Finally, it is concluded that focus should be on low U-values and emissions rather than on costs which should not be the deciding factor. Buildings should be renovated within the renovation cycle developed by the Energimyndigheten and Boverket for impact on CO2-emissions and climate. Other measures for improvements are also proposed in this study.
34

Val av stomsystem för en offentlig lokal : Fallstudie avseende entreprenadformen partnering och beaktade av miljöperspektiv / Choice of frame system for a public premise : Case study regarding contractual partnerships and consideration of environmental perspectives

Athanasiadis, Michail, Al Sahi, Hussein January 2018 (has links)
Produktion och drift av byggnader står för en stor del av de globalakoldioxidutsläppen och därför är det viktigt att utreda vilken betydelse valet avbyggnaders stomsystem har avseende energiförbrukning och klimatpåverkan underen livscykel. Syfte med denna studie är dels att visa hur olika delar av ett stomsystemi en offentlig lokal kan utvärderas och väljas med hänsyn till miljöpåverkan och delsatt utreda hur entreprenad-/samarbetsformen partnering fungerar vid utvecklingen aven offentlig lokal. En fallstudie på en nyligen uppförd psykiatrilokal genomfördes och studien somomfattade genomgång av projekthandlingar, intervjuer med aktörer i projektet ochberäkningar visade att byggnaden till stor del kunde har byggts med trästommeistället för med betongstomme. Detta hade kunnat leda till såväl minskadetransmissioner som minskade koldioxidutsläpp från tillverkningen av material.Orsaker till att man i partneringprojektet valde prefabricerade betongytterväggar,snarare än en lösning med trästomme, var framför allt byggentreprenörens störrevana vid att arbeta med betong, i kombination med att beställaren inte ville riskera enlång produktionstid eller oväntade kostnader. Mer tid för dialog, analys och störreöppenhet för att arbeta med nya lösningar hade kunnat leda till en mer miljövänligstomlösning. / Production and operation of buildings accounts for a large part of global carbondioxide emissions, and it is therefore important to investigate the importance of thechoice of buildings' frame systems in terms of energy consumption and climateimpact over a lifecycle. The purpose of this study is partly to show how differentparts of a frame system in a public premise can be evaluated and chosen on the basisof environmental impact and partly to investigate how the contractual-/collaborativepartnership work in the development of a public premise. A case study of a newly established psychiatric clinic was conducted, and the studyincluded review of project documents, interviews with project participants andcalculations. The results showed that the building could, to a large extent, beconstructed with wood rather than with concrete. This would have resulted in bothreduced transmissions of heat and reduced carbon dioxide emissions from theproduction of materials. The reasons for choosing the prefabricated concrete slabs inprefabricated concrete walls, rather than a wood-based solution, were above all thecontractor's greater experience of working with concrete, coupled with the fact thatthe client would not risk a long production time or unexpected costs. More time fordialogue, analysis and greater openness for working with new solutions could haveled to a more environmentally friendly solution.
35

HotHumiBox, ett provelement mellan två kammare / HotHumiBox, a test element between two chambers

Lekic, Dragan January 2018 (has links)
HotHumiBox är en försöksutrustning som finns på Linnéuniversitetet och som ska ge bättre kunskap och förståelse om hur fukt och temperatur varierar i en provkropp monterad mellan två kammare där klimatet kan styras var för sig. Syftet med examensarbetet är att undersöka om HotHumiBoxen fungerar väl och huruvida den kan börja användas i undervisningen i olika kurser inom institutionen för byggteknik på Linnéuniversitetet, bl.a. i samband med demonstrationslaborationer vid föreläsningar om fukt. För att genomföra arbetet har mätningar med tre olika klimat utförts på ett provelement som motsvarar en yttervägg som kan finnas i nybyggda typhus. Resultatet av mätningar utförda med HotHumiBoxen presenteras i form av tabeller och diagram och jämförs slutligen med beräkningar av fukt- och temperaturtillstånd. Jämförelsen mellan mätningar och beräkningar visar att givarna som styr klimatet i båda kamrarna visar mycket bra resultat. Däremot visar majoriteten av givarna i provelementet antingen lite för höga eller för låga värden för att resultatet ska anses som tillfredställande. För att få en bekräftelse på att HotHumiBoxen fungerar väl rekommenderas därför att ytterligare mätningar görs. / HotHumiBox is an experimental equipment that is available at Linnaeus University and is supposed to provide better knowledge and understanding about the way moisture and temperature varies in a building element installed between two chambers in which the climate can be controlled separately. The purpose of this work is to investigate whether the HotHumiBox works well and whether it can be used at various courses at the Department of Building Technology at Linnaeus University, such as demonstration laboratory experiments at lectures on moisture. Measurements with three different climates were performed on a building element that corresponds to a wall that could be installed in modern houses. The results of the HotHumiBox measurements are being presented in tables and diagrams and are being compared with moisture and temperature calculations. The comparison between measurements and calculations shows that the sensors which control the climate in both chambers show very good results. On the other hand, the majority of the sensors in the test element show either too high or too low values for the result to be considered as satisfactory. Therefore, it is recommended that some more tests and measurements are done before it can be concluded that the HotHumiBox work well.
36

Robust and Durable Vacuum Insulation Technology for Buildings

Karami, Peyman January 2015 (has links)
Today’s buildings are responsible for 40% of the world’s energy use and also a substantial share of the Global Warming Potential (GWP). In Sweden, about 21% of the energy use can be related to the heat losses through the climatic envelope. The “Million Program” (Swedish: Miljonprogrammet) is a common name for about one million housing units, erected between 1965 and 1974 and many of these buildings suffer from poor energy performance. An important aim of this study was to access the possibilities of using Vacuum Insulation Panels (VIPs) in buildings with emphasis on the use of VIPs for improving the thermal efficiency of the “Million Program” buildings. The VIPs have a thermal resistance of about 8-10 times better than conventional insulations and offer unique opportunities to reduce the thickness of the thermal insulation. This thesis is divided into three main subjects. The first subject aims to investigate new alternative VIP cores that may reduce the market price of VIPs. Three newly developed nanoporous silica were tested using different steady-state and transient methods. A new self-designed device, connected to a Transient Plane Source (TPS) instrument was used to determine the thermal conductivity of granular powders at different gaseous pressure combined with different mechanical loads. The conclusion was that the TPS technique is less suitable for conducting thermal conductivity measurements on low-density nanoporous silica powders. However, deviations in the results are minimal for densities above a limit at which the pure conduction becomes dominant compared to heat transfer by radiation. The second subject of this work was to propose a new and robust VIP mounting system, with minimized thermal bridges, for improving the thermal efficiency of the “Million Program” buildings. On the basis of the parametric analysis and dynamic simulations, a new VIP mounting system was proposed and evaluated through full scale measurements in a climatic chamber. The in situ measurements showed that the suggested new VIP technical solution, consisting of 20mm thick VIPs, can improve the thermal transmittance of the wall, up to a level of 56%. An improved thermal transmittance of the wall at centre-of-panel coordinate of 0.118 to 0.132 W m-2K-1 and a measured centre-of-panel thermal conductivity (λcentre-of-panel) of 7 mW m-1K-1 were reached. Furthermore, this thesis includes a new approach to measure the thermal bridge impacts due to the VIP joints and laminates, through conducting infrared thermography investigations. An effective thermal conductivity of 10.9 mW m-1K-1 was measured. The higher measured centre-of-panel and effective thermal conductivities than the published centre-of-panel thermal conductivity of 4.2 mW m-1K-1 from the VIP manufacturer, suggest that the real thermal performance of VIPs, when are mounted in construction, is comparatively worse than of the measured performance in the laboratory. An effective thermal conductivity of 10.9 mW m-1K-1 will, however, provide an excellent thermal performance to the construction. The third subject of this thesis aims to assess the environmental impacts of production and operation of VIP-insulated buildings, since there is a lack of life cycle analysis of whole buildings with vacuum panels. It was concluded that VIPs have a greater environmental impact than conventional insulation, in all categories except Ozone Depilation Potential. The VIPs have a measurable influence on the total Global Warming Potential and Primary Energy use of the buildings when both production and operation are taken into account. However, the environmental effect of using VIPs is positive when compared to the GWP of a standard building (a reduction of 6%) while the PE is increased by 20%. It was concluded that further promotion of VIPs will benefit from reduced energy use or alternative energy sources in the production of VIP cores while the use of alternative cores and recycling of VIP cores may also help reduce the environmental impact. Also, a sensitivity analysis of this study showed that the choice of VIPs has a significant effect on the environmental impacts, allowing for a reduction of the total PE of a building by 12% and the GWP can be reduced as much as 11% when considering both production and operation of 50 yes. Finally, it’s possible to conclude that the VIPs are very competitive alternative for insulating buildings from the Swedish “Million Program”. Nevertheless, further investigations require for minimizing the measurable environmental impacts that acquired in this LCA study for the VIP-insulated buildings. / Dagens byggnader ansvarar för omkring 40% av världens energianvändning och  står också för en väsentlig del av utsläppen av växthusgaser. I Sverige kan ca 21 % av energianvändningen relateras till förluster genom klimatskalet. Miljonprogrammet är ett namn för omkring en miljon bostäder som byggdes mellan 1965 och 1974, och många av dessa byggnader har en dålig energiprestanda efter dagens mått. Huvudsyftet med denna studie har varit att utforska möjligheterna att använda vakuumisoleringspaneler (VIP:ar) i byggnader med viss fokus på tillämpning i Miljonprogrammets byggnader. Med en värmeledningsförmåga som är ca 8 - 10 gånger bättre än för traditionell isolering erbjuder VIP:arna unika möjligheter till förbättrad termisk prestanda med minimal isolerings tjocklek. Denna avhandling hade tre huvudsyften. Det första var att undersöka nya alternativ för kärnmaterial som bland annat kan reducera kostnaden vid produktion av VIP:ar. Tre nyutvecklade nanoporösa kiselpulver har testats med olika stationära och transienta metoder. En inom projektet utvecklad testbädd som kan anslutas till TPS instrument (Transient Plane Source sensor), har använts för att mäta värmeledningsförmågan hos kärnmaterial för VIP:ar, vid varierande gastryck och olika mekaniska laster. Slutsatsen blev att transienta metoder är mindre lämpliga för utföra mätningar av värmeledningsförmåga för nanoporösa kiselpulver låg densitet. Avvikelsen i resultaten är dock minimal för densiteter ovan en gräns då värmeledningen genom fasta material blir dominerande jämfört med värmeöverföring genom strålning. Det andra syftet har varit att föreslå ett nytt monteringssystem för VIP:ar som kan användas för att förbättra energieffektiviteten i byggnader som är typiska för Miljonprogrammet. Genom parametrisk analys och dynamiska simuleringar har vi kommit fram till ett förslag på ett nytt monteringssystem för VIP:ar som har utvärderats genom fullskaleförsök i klimatkammare. Resultaten från fullskaleförsöken visar att den nya tekniska lösningen förbättrar väggens U-värde med upp till 56 %. En förbättrad värmegenomgångskoefficienten för väggen i mitten av en VIP blev mellan 0.118 till 0,132 W m-2K-1 och värmeledningstalet centre-av-panel 7 mW m-1K-1 uppnåddes. Detta arbete innehåller dessutom en ny metod för att mäta köldbryggor i anslutningar med hjälp av infraröd termografi. En effektiv värmeledningsförmåga för 10.9 mW m-1K-1 uppnåddes. Resultaten tyder även på att den verkliga termiska prestandan av VIP:ar i konstruktioner är något sämre än mätvärden för paneler i laboratorium. En effektiv värmeledningsförmåga av 10.9 mW m-1K-1 ger dock väggkonstruktionen en utmärkt termisk prestanda. Det tredje syftet har varit att bedöma miljöpåverkan av en VIP-isolerad byggnad, från produktion till drift, eftersom en livscykelanalys av hela byggnader som är isolerade med vakuumisoleringspaneler inte har gjorts tidigare. Slutsatsen var att VIP:ar har en större miljöpåverkan än traditionell isolering, i alla kategorier förutom ozonnedbrytande potential. VIP:ar har en mätbar påverkan på de totala utsläppen av växthusgaser och primärenergianvändningen i byggnader när både produktion och drift beaktas. Miljöpåverkan av de använda VIP:arna är dock positiv jämfört med GWP av en standardbyggnad (en minskning med 6 %) medan primärenergianvändningen ökade med 20 %. Slutsatsen var att ytterligare användning av VIP:ar gynnas av reducerad energiförbrukning och alternativa energikällor i produktionen av nanoporösa kiselpulver medan användningen av alternativa kärnmaterial och återvinning av VIP kärnor kan hjälpa till att minska miljöpåverkan. En känslighetsanalys visade att valet av VIP:ar har en betydande inverkan på miljöpåverkan, vilket ger möjlighet att reducera den totala användningen av primärenergi i en byggnad med 12 % och utsläppen av växthusgaser kan vara minska, så mycket som 11 % när det gäller både produktion och drift under 50 år. Avslutningsvis är det möjligt att dra slutsatsen att VIP:ar är ett mycket konkurrenskraftigt alternativ för att isolera byggnader som är typiska för Miljonprogrammet. Dock krävs ytterligare undersökningar för att minimera de mätbara miljöeffekter som förvärvats i denna LCA-studie för VIP-isolerade byggnader. / <p>QC 20151109</p> / Simulations of heat and moisture conditions in a retrofit wall construction with Vacuum Insulation Panels / Textural and thermal conductivity properties of a low density mesoporous silica material / A study of the thermal conductivity of granular silica materials for VIPs at different levels of gaseous pressure and external loads / Evaluation of the thermal conductivity of a new nanoporous silica material for VIPs – trends of thermal conductivity versus density / A comparative study of the environmental impact of Swedish residential buildings with vacuum insulation panels / ETICS with VIPs for improving buildings from the Swedish million unit program “Miljonprogrammet”
37

Energieffektivisering av skolor : En studie om energieffektivisering och inneklimat för Rotundaskolan i Västerås

Granlund, Fredric, Nilsson, Alexander, Sundström, Patrik January 2021 (has links)
Purpose: This study aims to see how the total active heating demand and the indoor climate for a school in Vasteras can improve from two different energysaving-investments. The two measures that will be investigated are windows with an improved U-value and an exchange of the ventilation unit with a heat exchanger. The result of the investments will be connected to a value-added study which investigates its impact on social, economy and environmental aspects. Method: To accomplish this, a literature study has been made to gather information to support the calculations and compare our results with previous studies. A case study which consists of calculations, a study visits to the school and a documentation analysis to strengthen the accuracy of the results. Results: The yearly total active heating for the school was 426 MWh with a heat demand of 191 kWh/m2 which is bad compared to equal buildings which normally use between 120-180 kWh/m 2. The exchange of the ventilation unit and the implement of a heat exchanger decreased the yearly active heating demand with 105 MWh which is equal to 144 kWh/m2. This is a much better value and now in the category of equal buildings. By investing in windows with a U-value of 1.3 W/m2 K from 3.0 W/m2 saved the building 29 MWh every year to 178 kWh/m2 which is just under the maximum value of 180 kWh/m 2 . Conclusions: Investing in a new ventilation unit with a heat exchanger showed to be the best investment for the school at this moment in time. The new heat exchanger contributes to a large energy saving and the investment cost had a payback time between 9 - 18 years depending on the kWh price. The study got similar results in the value-added study where the ventilation unit showed a greater impact on almost all of FN: s global goals. Windows did not show as impressive results as the ventilation unit did and is why it contributed less to the global goals in the value-added study.
38

Undersökning av grundläggningsmetod, kantbalkar utförda med glas, polystyren och korslimmat-trä.

Eliasson, Daniel, Carlsson, Olle January 2023 (has links)
Byggbranschen bidrar till stora utsläpp av växthusgaser, och det är därför viktigt att utforska hållbara material för att minska påverkan. Studien fokuserar på grundfundament för mindre trähus i Sverige, där betong i platta på mark ersätts med korslimmat trä (KLT) för att reducera klimatpåverkan. Eftersom betong har hög tryckhållfasthet gjordes analys av kantbalkens kapacitet. Fyra alternativ på kantbalkar undersöks: KLT/EPS400, KLT/Foamglas, KLT/EPS s100 och EPS400. Studien bedömer även den nuvarande dimensioneringen i hållfasthetsberäkningarna. Testdata för tryckhållfasthet används för att jämföra med förväntade resultat och avgöra om beräkningsmodellen ”2:1 metoden” är tillräcklig.Syftet är att bedöma möjligheterna för användning i två hustyper hos en ledande hustillverkare i Sverige. Miljöpåverkan av alternativen beräknas med IVL Svenska Miljöinstitutets verktyg, BM, där även en betonggrund jämförs. Det utförs även en enklare insikt i skillnader av produktion mellan en klassisk betonggrund och Klaragrunden. Studien visade att 1-plansvillan Lycke kan utföras med KLT och EPS s100, och att 1,5-plansvillan Tyresund kan se möjligheter med KLT och FoamglasT4+. Studien visade också att den bästa genomsnittliga grunden är KLT och EPS s400. Genom att byta ut betongen i en platta på mark med KLT, gör det möjligt att sänka grundens CO2 utsläpp med 65-68%. / The construction industry contributes significantly to greenhouse gas emissions, making it crucial to explore sustainable materials to reduce its impact. This study focuses on foundation systems for small wooden houses in Sweden, where concrete slabs are replaced with cross-laminated timber (CLT) to decrease climate impact. Due to concrete's high compressive strength, an analysis of the edge beam's capacity was done. Four edge beam alternatives are examined: CLT/EPS400, CLT/Foamglas, CLT/EPS s100, and EPS400. The study also evaluates the current dimensioning in strength calculations. Compression strength test data is used to compare with expected results and determine if the calculation model "2:1 method" is sufficient. The aim is to assess the possibilities for use in two house types from a leading house manufacturer in Sweden. The environmental impact of the alternatives is calculated using IVL Swedish Environmental Institute's tool, BM, where a concrete foundation is also compared. There is also a brief insight into the differences in production between a traditional concrete foundation and Klaragrunden. The findings indicated that the single-story villa Lycke can be constructed using CLT and EPS s100, while the 1.5-story villa Tyresund can explore possibilities with CLT and Foamglas T4+. Moreover, the study revealed that the CLT and EPS s400 combination yielded the best average foundation. By replacing the concrete in a ground slab with CLT, it is possible to reduce the CO2 emissions from the foundation by 65-68%.
39

Byggnadsutformning för ett framtida varmare klimat : Klimatscenariers påverkan på energianvändning och termisk komfort i ett flerbostadshus och alternativa byggnadsutformningar för att förbättra resultatet / Building design for a future warmer climate : Climate scenarios impact on energy demand and the thermal comfort in an apartment building and alternative constructions to improve the results

Monfors, Lisa, Morell, Corinne January 2020 (has links)
När byggnader projekteras används klimatfiler från 1981-2010 för att dimensionera konstruktionen och energisystemet. Detta leder till att byggnader dimensioneras för ett klimat som varit och inte ett framtida klimat. SMHI har tagit fram olika klimatscenarier för framtiden som beskriver möjliga utvecklingar klimatet kan ta beroende på fortsatt utsläpp av växthusgaser. Dessa scenarier kallas för RCP (Representative Concentration Pathways). I denna studie används två olika klimatscenarier, RCP4,5 och RCP8,5. Siffran i namnet står för den strålningsdriving som förväntas uppnås år 2100. I RCP4,5 kommer medelårstemperaturen öka med 3 °C fram till år 2100 jämfört med referensperioden 1961-1990.  För samma tidsperiod sker en ökning på 5 °C enligt RCP8,5.  Ett flerbostadshus certifierad enligt Miljöbyggnad 2.2 nivå silver placerat i Vallentuna i Stockholms län används i denna studie som referensbyggnad. Byggnaden simuleras i programmet IDA ICE där den utsätts för RCP4,5 och RCP8,5. Resultatet visar att byggnaden inte skulle klara av kraven för Miljöbyggnad 2.2 gällande termiskt klimat sommar i något av de två klimatscenarierna. De operativa temperaturerna blir för höga i byggnaden utan att tillsätta komfortkyla.  Byggnaden ändras för att se vilka faktorer som kan förbättra resultatet gällande det termiska klimatet. Resultatet visar att värmelagringsförmåga hos byggmaterial och solavskärmning har störst påverkan på det termiska klimatet.  I studien gjordes flertal olika kombinationer av byggnadsutformningar. Enbart kombinationen av en tung stomme av betong tillsammans med fönster med lägre g-värde klarar kraven för Miljöbyggnad 2.2 i RCP4,5 och RCP8,5 utan komfortkyla. Kombinationen får lägst energianvändning i RCP8,5 av de olika kombinationerna som testats i studien.  En kombination av tung stomme av KL-trä med lågt U-värde, fönster med lägre g-värde och komfortkyla får lägst energianvändning i grundklimatet och RCP4,5 av de olika kombinationerna som testats i studien trots användningen av komfortkyla.  Frågan om vilket alternativ som är bäst ur ett hållbarhetsperspektiv är svårt att svara på. Det finns många aspekter som behöver tas i hänsyn till som byggnadens totala klimatavtryck både i tillverkning och användning. Oavsett val av konstruktion är det viktigt att projektera för att komfortkyla och solavskärmning skall kunna appliceras när ett varmare klimat råder. / When buildings are designed climate files from 1981 to 2010 are used to construct the building and its energy system. This leads to building being designed to a climate that has been and not to a future warmer climate that will come. SMHI has developed different climate scenarios for the future that describe different paths the climate can take depending on continued emissions of greenhouse gas. This climate scenarios are called RCP (Representative Concentration Pathways) In this study two of the climate scenarios, RCP4,5 and RCP8,5 are used. The number in the name stands for the radiation forcing that is expected in the year 2100.  In RCP4,5 the mean average air temperature will increase with 3 °C until year 2100 compared to the reference period 1961-1990. In the same time period RCP8,5 will increase with 5 °C.  An apartment building certified according to Miljöbyggnad 2.2 level silver placed in Vallentuna, Stockholms län is used as a reference building. The building is simulated through the simulation software program IDA ICE where it´s exposed to RCP4,5 and RCP8,5. The results demonstrate that the reference building would not meet Miljöbyggnad 2.2 requirement in the indicator about thermal comfort during summer. The operative temperature in the building is too high unless comfort cooling is used.  The design of the building changes to see what factors can improve the results regarding the thermal comfort. The results demonstrate that thermal conductivity and solar shading has the greatest impact on thermal comfort.  In this study several combinations of different building designs were made. Only the combination of a concrete frame with windows with low g-value met the requirement of Miljöbyggnad 2.2 regarding the thermal comfort during summer without using comfort cooling in RCP4,5 and RCP8,5. The combination had the lowest energy demand in RCP8,5 of all the combinations tested in the study.  A combination of cross laminated wood frame with low U-value, windows with low g-value and comfort cooling had the lowest energy demand in the original climate file and RCP4,5 despite the use of comfort cooling.  The questing about which building construction is the best from a sustainable perspective is difficult to answer. To answer that question the building´s total climate footprint in both production and use must be calculated. Regardless of the choice of building construction it is important to have in mind when designing a building that comfort cooling and solar shading should be easily applied when a warmer climate will prevail.

Page generated in 0.0569 seconds