Spelling suggestions: "subject:"find"" "subject:"kind""
31 |
Compound Extreme Wind and Precipitation Events in Europe / Sammanfallande extrema vind- och nederbördsändelser i EuropaJohansson, Elisabet January 2021 (has links)
The simultaneous occurrences of several extreme events, known as compound extremes, are often associated with greater impact than univariate extremes. Flooding and windstorms are widespread hazards in Europe which can lead to severe property damage and fatalities. During winter, extreme wind and precipitation often co-occur, since they are associated with a common driver, namely extratropical cyclones. In this project, the occurrences of compound wind and precipitation events in Europe are investigated using the ERA5 reanalysis dataset. The analysis covers the years 1979-2019 with a focus on boreal winter. Areas that experience the highest occurrence of compound wet-windy extremes are the west coast of Norway, the Iberian peninsula, parts of central Europe, and southeast of the Black Sea. A few case studies are discussed with the purpose to give an idea of the magnitude of possible impacts. Further, the relationship between extreme wind and precipitation events and the North Atlantic Oscillation (NAO) is presented. During days with positive NAO, extreme precipitation and wind events occur in the central and northern parts of Europe while the negative phase brings extreme wind and precipitation to the southern parts of Europe. Lastly, a short analysis to discover changes in the occurrences of compound precipitation and wind events for the two periods 1979-1999 and 2000-2019 is performed. The result showed no clear changes. The number of compound extremes does not seem to vary for the two periods. / Olika extrema väderhändelser som sammanfaller orsakar ofta större skada än enskilda extrema händelser på många håll i samhället. Översvämningar och vindstormar är vanligt förekommande i Europa och kan leda till kostsamma skador och dödsfall. Extrema vind-och nederbördshändelser sammanfaller vanligen under vintern eftersom de båda ofta orsakas av Nordatlantiska cykloner, som är vanligast under den årstiden. I detta projekt kartläggs sammanfallande vind- och nederbördshändelser i Europa under vintermånaderna december-februari, med hjälp av ERA5 reanalysdata för åren 1979-2019. Områden med relativt hög förekomst av sammanfallande vind- och nederbördshändelser är Norges västkust, Iberiska halvön, delar av Centraleuropa och östra Turkiet. Några fallstudier kopplade till dessa områden är diskuterade för att ge en uppfattning om konsekvenserna av dessa sammanfallande händelser. Eventuella kopplingar mellan sammanfallande vind- och nederbördshändelser och den Nordatlantiska Oscillationen (NAO) är också undersökt. Under den positiva fasen av NAO sker extrema nederbörd- och vindhändelser i norra och centrala delar av Europa medan den negativa fasen ger extrem vind och nederbörd i de södra delarna av Europa.En kort analys för undersöka om förekomsten av extrema sammanfallande händelser har ändrats genomfördes genom att jämföra andelen sammanfallande händelser under de två perioderna 1979-1999 och 2000-2019. Ingen betydande förändring i andelen sammanfallande händelser mellan dessa perioder hittades.
|
32 |
Welcome to the end of the world : En analys av ljudbilden i True Detective: Night Country / Welcome to the end of the world : A analysis of the soundscape in True Detective: Night CountryRohde Vittsell, Måns January 2024 (has links)
The purpose of this study is to analyze and seek for a possible meaning and suggestion behind the soundscape in the first episode of True Detectives fourth season; Night Country. Four individual elements have been selected for deeper analysis and based upon those, six scenes where those elements are present were selected for the study. Each auditory element that was selected was then analyzed in depth looking at the more technical aspects of identifying and categorizing sound but also how it impacts the audience on an emotional and narrative level to explore, not only how the soundscape is established early on, but what effects this has on the viewers expectations and predictions for how the narrative could unfold. The results of this study points towards there being, for the first time in the series history, something paranormal happening in the world of the characters. Despite there being hints and suggestions that paranormal activity is part of the cinematic world of True Detective in the past, this has never been the case once the mysteries unfold but the soundscape in Night Country, as early as episode one, and the results of this study suggests that this is about to change. / The purpose of this media production is to be used as a base for discussion during seminars regarding honor related violence and oppression. The mateiral is the be used during education for proffesionals in the field of social work.
|
33 |
Termisk stigning i höga byggnader : Vindens påverkan / Thermal flow in high-rise buildings : The influence of the windWalldén, Jimmy January 2019 (has links)
Att tillhandahålla termisk komfort är ett av de främsta kraven som ställs på byggnader i dagens samhälle. Stora delar av energianvändningen går därför åt till att styra inomhusklimatet för att upprätthålla en behaglig nivå. Det påstås att omkring 40 % av denna energi tillkommer på grund av energiförluster via öppningar och läckage genom byggnaders klimatskal. Med tanke på världens och Sveriges alltmer striktare energikrav där man bland annat vill bygga nära-nollenergibyggnader är detta någonting som bör förbättras. Det är därför viktigt att förstå hur men även varför denna luftinfiltration uppstår och vilka faktorer som har en påverkande effekt. Detta arbete innefattas av tre olika simuleringsstudier av en hög byggnad där inomhusluftens rörelsemönster samt yttre vindförhållanden har legat i fokus. En studie utfördes med hjälp av simuleringsverktyget IDA ICE där luftens infiltration undersöktes. De andra två utfördes med hjälp av CFD-programmet COMSOL Multiphysics v5.4. Den ena CFD-studien studerade termiska stigkrafter inuti byggnaden och den andra studerade vindens flödesmönster utanför byggnaden och varför infiltrationen beter sig som den gör. Resultatet av simuleringarna i IDA ICE visar att det är möjligt att minska infiltrationsmängden luft in i byggnaden från 1384 l/s till 804 l/s genom att ta hänsyn till ytterdörrens placering relativt den inkommande vinden riktning. De visar även att infiltrationens inflöde är som högst på bottenvåningen för att sedan minska och därefter övergå till ett utflöde på de högre våningsplanen.Resultatet från den första CFD-studien beskriver hur den varmare inomhusluftens rörelsemönster förändras då kallare luft tar sig in på byggnadens bottenvåning. Detta förändrade rörelsemönster resulterar i att den varmare luften stiger och därmed letar sig ut genom byggnadens högre våningsplan. Den andra CFD-studiens resultat beskriver hur den yttre vindens flödesmönster förändras då dess infallsvinkel mot byggnaden varierar. Flödesmönstrets förändring ger i sin tur upphov till en varierande tryckskillnader på utsidan samt inuti byggnaden. Detta är därför en av förklaringarna till varför infiltrationen är som högst då vinden blåser rakt mot byggnadens öppna dörr jämfört med när den kommer med en annan infallsvinkel. Slutsatsen är att ytterdörrens placering relativt den yttre vinden rörelsemönster bör tas i beaktning vid nybyggnation av höga byggnader eller renovering av redan befintliga byggnader. Detta för att minimera infiltrationen och därmed reducera den problematik som infiltrationen kan medföra. / One of the main requirements a building have is to provide thermal comfort inside it. Therefore, large parts of the energy consumptions is used to control the indoor climate in order to maintain a comfortable level in the building. It’s alleged that around 40 % of this energy is added due to energy losses through opening and leakages in the buildings enclosure. Considering the world’s increasing energy requirements, where among other things one future requirement is to build nearly-zero energy buildings, is this something that needs to be improved. It’s therefore important to understand how, and also why this air infiltration occurs and what’s affecting it. This master thesis contains of three different types of simulation studies where the air inside a high-rise building, and also the wind flow around it was analyzed. One of these three studies was performed with the simulation program IDA ICE, where the air infiltration was examined. The other two studies were performed with the CFD-software, COMSOL Multiphysics v5.4. One of these CFD-studies examined the thermal flow that occurs inside the building. The other one examined the wind’s flow pattern outside the building and why the air infiltration behavior is like it is. The results from the IDA ICE simulations shows that it’s possible to decrease the infiltration rate of air into the building from 1384 l/s to 804 l/s by taking the exterior door’s position relative the incoming wind’s direction into account. They also show that the infiltration inflow is highest on the ground floor before it starts to decrease and then change and becomes an outflow on the the higher floors. The results from the first CFD-study describes how the movements of the warmer air inside the building changes when colder air flows in on the ground floor. This changed air movement pattern makes the warmer air rise, and thus flow out through the enclosure on the higher parts of the building. The other CFD-study describes how the flow pattern of the outside wind changes around the building when the winds angle of incidence varies. The changed flow pattern causes varying pressure differences, both on the outside and the inside of the building. This is therefore the explanation to why the infiltration rate is greatest when the wind blows straight towards the opened door on the building instead of with other angles of incidence. The conclusion is that the placement of exterior doors on high-rise buildings relative to the outside wind should be taken into account when new buildings are built or when a renovation of an existing building should be made. This to minimize air infiltration through buildings and thereby reduce problems infiltration can cause.
|
34 |
Reindeer Husbandry and Wind Power : Discourses surrounding the construction of IKEA's wind park on Glötesvålen and its local effects on reindeer husbandryAugustsson, Adam January 2021 (has links)
The exploitation of land in Northern Sweden has caused a significant depletion of grazing grounds for semi-domesticated reindeer. This is a threat to the indigenous Sami reindeer herders of Sweden, who rely on the grazing ground in order to sustainably feed their herds. In the last decade, a significant amount of grazing land has been lost due to the construction of wind power parks (WPP) in important grazing regions. This thesis examines the discourse surrounding a WPP built in Härjedalen for IKEA. The WPP was built on Glötesvålen, a unique highland used for grazing by Mittådalen, a local herding community. Through a dissection of electronic sources and semi-structured interviews, the author conducts a discourse analysis to identify the most prevalent narratives surrounding the construction of IKEA’s WPP on Glötesvålen. An inductive approach is used to identify underlying ideologies present in the discourse through a relevant theoretical framework. The results show a pervasive enthusiasm for the WPP as a pivot towards renewable energy which mirrors the ideology of ecological modernization. The results also find a critical narrative which lifts the uneven power dynamic experienced by reindeer herders. This narrative is understood through the lens of Spivak’s (2010) “Can the Subaltern Speak?”. An additional discourse found is the symbolic issue between industrial ecological transitioning and the right to reindeer husbandry as a cultural heritage. / Exploateringen av mark i norra Sverige har orsakat en betydande förlust av betesmarker för renskötare. Detta hotar den svensk-samiska rennäringen, som förlitar sig på betesmarken för att hållbart mata sina hjordar. Under det senaste decenniet har en betydande mängd betesmark gått förlorad på grund av den ökande mängden vindkraftsparker (WPP) på, eller intillrenbetesmarker. Denna avhandling undersöker diskursen kring en WPP byggd i Härjedalen för IKEA. WPP byggdes på Glötesvålen, ett låg-fjäll som tidigare haft strategiskt viktiga betesmarker för samebyn Mittådalen. Genom en dissektion av elektroniska källor och halvstrukturerade intervjuer genomför författaren en diskursanalys för att identifiera de vanligaste narrativen om IKEAs vindkraftpark på Glötesvålen. En induktiv metod används för att identifiera underliggande ideologier som finns i diskursen genom ett relevant teoretisk ramverk. Resultaten visar en genomgripande entusiasm för vindkraft som ett steg mot förnybar energi. Detta narrativ speglar ideologin för ekologisk modernisering. Resultaten hittar också ett kritisk narrativ som lyfter den ojämna maktdynamiken som renskötarna upplever. Detta förstås genom Spivaks (2010) "Kan den underordnade tala?". Ytterligare en diskurs som upptäcks är symbolfrågan mellan industriell ekologisk omställning och bevarandet av renskötseln som kulturarv.
|
35 |
Fuktstudie om uteluftsventilerade vindar med beräkningsprogrammet Simple Cold Attic Model från Annex 55 / Moisture related Study in outdoor air ventilated attics with the calculation program Simple Cold Attic Model from Annex 55Holck-Clausen, Jens, Mattisson, Karin January 2014 (has links)
Fuktskador på uteluftsventilerade vindar är ett ökat problem, i det mer miljömedvetna Sverige. Genom tjockare vindsbjälklagsisolering minskar både energiförlusten genom bjälklaget och uppvärmningsbehovet i huset, men hur många funderar på vad som händer med det förändrade klimatet på vinden och hur det kan påverka fuktförhållandena i utsatta delar av konstruktionen. Studier från Chalmers Tekniska Högskola har framställt ett fuktberäkningsprogram för uteluftsventilerade vindar vid namn Simple Cold Attic Model. Programmets funktion och potential har prövats i denna rapport genom en beräkningsanalys av en uteluftsventilerad vindskonstruktion. Försök till att förbättra fuktsäkerheten i konstruktionen har utförts och redovisas i rapporten. Studien har påvisat att den studerade konstruktionen inte är fuktsäker om den uppförs i Stockholmsområdet. Det visades även att aktiva val i konstruktionen kan förebygga fuktskador. Studien har påvisat vikten av inte beräkna med medelår för klimat och hur det påverkar beräkningsresultatet av mögeltillväxt. Detta har understrukit vikten av att ha ett beräkningsprogram som Simple Cold Attic Model som kraftigt reducerar beräkningsmängden vid fuktriskbedömning. Rekommendationen till företaget AK Konsult är att tillämpa beräkningsprogrammet när det har utvecklats till fullo. / Moisture Damage in outdoor air ventilated attics is a growing problem in the more environmentally conscious Sweden. Thick ceiling insulation reduces both energy loss through the soffit and the need for heating in the house, but how many people are thinking about what happens to the changing climate on the wind and how it can affect moisture conditions in deprived parts of the structure.Studies from Chalmers University of Technology have resulted in a moisture calculation program for outdoor air ventilated attics named Simple Cold Attic Model. The program's performance and potential have been examined in this report, through a calculation analysis of an outdoor air ventilated attic construction. Attempts to improve the moisture safety in the construction have been carried out and are presented in this report.The study has demonstrated that the studied structure is not moisture-proof if it is built in the Stockholm area. It also shows that an active choice in the design can prevent moisture damage. The study has shown the importance of not calculating with an average year for climate and how it affects the calculation result of mold growth. This emphasizes the importance of having a calculation tool as Simple Cold Attic Model, that significantly reduces the amount of calculations in the assessment of moisture related damage. The recommendation for AK Konsult is to apply the calculation program when it is fully developed.
|
36 |
Study of NEOM city renewable energy mix and balance problemAlkeaid, Majed Mohammed G January 2018 (has links)
It is important for NEOM management in the contemporary world to put in place NEOM projects using the available resources. The region in which the NEOM project is spacious and vast with conditions suited to generate energy from solar and wind. The NEOM projectis expected to be set up in the very resourceful state of Saudi Arabia. The purpose of the study is to assist in setting up a sustainable city through the exploitation of solar and wind energy. The aim of the study was to assist in the generation of more than 10 GW renewable energy to replace approximately 80,000 barrels of fossil energy. The problem of coming up with renewable and sustainable energy from the unexploited sources is addressed. The renewable city is expected to be a technological hub based on Green Energy with 100% renewable energy, which is correspond to 72:4GW. Freiburg and Masdar as renewable cities are used as case studies in the research. NEOM power generation capacity is capable to cover Saudi Arabia power generation capacity (approximately 71GW), which is more than enough for a city. The study reveals that the total power generation from wind farms, tidal farms, solar stations, and solar power tower stations are 9:1373GW, 4:76GW, 57:398GW and 1:11GW respectively. Saudi Arabia has plans to set up 16 nuclear plants (17 GW each) for energy purposes (total of 272 GW), which will be part of Saudi Arabia national grid and will be more than enough to cover NEOM electricity demand in case NEOM does not reach demand capacity. In case NEOM energy does not meet the demand, electricity generation from 16 Nuclearpower plants generating 17GW each, and 6 Natural underground batteries with a capacity of 120MW each are recommended. The study results can be applied in NEOM Institute of Science and Technology for further research on renewable energy. The findings can also be used for research extension of HVDC transmission lines between NEOM and Saudi Arabia main grid, Egypt, and Jordan. / Det är viktigt för NEOM projektets ledning att planera och införa projektet med hjälp av förnybara energiresurser på plats. Regionen är rymligt och stort och är en lämplig plats för att kunna generera tillräcklig med energi från sol och vind för energiförsörjning av området. Syftet med studien är att studera en pågående planering och byggnation av en hållbar stad med upp till 10 GW förnybar energi som motsvarar cirka 80 000 fat fossil bränsle. Problem och utmaningar för att försörja en hel stad med förnybara energiresurser kommer att diskuteras. Den förnybara staden förväntas vara ett föredöme för 100% förnybar energi, vilket i kapacitetssammanhang motsvarar 72:4GW, vilket är mer tillräckligt än behovet för NEOM staden. Freiburg och Masdar städer används som fallstudier i examensarbetet. NEOMs kraftproduktionskapacitet kan täcka behovet av hela landet som uppgår till 71GW. Studien visar att den totala kraftproduktionskapaciteten från olika förnybara energiresurser såsom vindkraftparker, tidvattenanläggningar, solcellkraftverk och soltornskraftverk med en kapacitet av 9:1373GW,4:76GW, 57:398GW och 1:11GW respektive kan uppgå till 72:4GW. Saudiarabien har planer på att skaffa 16 kärnkraftverk (17GW vardera) med en total kapacitet på 272GW som kommer att ingå i Saudiarabiens nationella satsningar för framtidens elproduktion och det kan täcka elbehovet om NEOM inte når efterfrågekapaciteten. Utöver ovan har studien föreslagit 6 underjordiska batterier med en kapacitet på 120MW per batteri. Studieresultaten kan användas för kompetensuppbyggnad och vidare forskning om förnybara energiresurser för NEOM Institute of Science and Technology. Resultaten kan också användas för teknikutveckling och forskning inom HVDC- överföringsledningar mellan NEOM, Saudiarabiens huvudnät, Egypten och Jordanien.
|
37 |
Improving Water Droplet Prediction for Vehicle Exterior Water Management: Insights from Experimental and Simulation Studies / Förbättring av Förutsägelse av Vattendroppars Rörelse på Fordonsexteriörer: Insikter från Experiment och SimuleringarLabbé, Anton, Ahsan, Mahim January 2023 (has links)
This thesis focuses on the study of water transportation on vehicle surfaces, which is crucial for ensuring the unobstructed operation of sensors and cameras in autonomous vehicles. The research aims to develop and validate experimental and simulation methods to enhance the understanding of water droplet behaviour and to create accurate models for computational fluid dynamics (CFD) simulations. The primary objective is to investigate the feasibility of simulating water droplets using CFD. The study examines the behaviour of water droplets on a lacquered metal sheet and a glass surface. Physical experiments and CFD simulations are conducted to analyse droplet movement under the influence of gravity and airflow. The findings provide insights into the factors influencing droplet behaviour and validate the accuracy of the simulation models through physical tests. The research also discusses the limitations of the study and the implications for Volvo Cars, aiming to improve their ability to predict water droplet movement on their vehicles. / Denna avhandling fokuserar på studien av vattentransport på fordonssytor, vilket är avgörande för att säkerställa att sensorer och kameror i autonoma fordon kan fungera utan hinder. Forskningen syftar till att utveckla och validera experimentella och simuleringsmetoder för att förbättra förståelsen av vattendroppars beteende och skapa noggranna modeller för simuleringar inom beräkningsfluidmekanik (CFD). Det primära målet är att undersöka möjligheten att simulera vattendroppar med hjälp av CFD och deras påverkan på fordonssytor. Studien undersöker beteendet hos vattendroppar på en lackerad metallplåt och en glasyta med varierande lutningsvinklar. Fysiska experiment och CFD-simuleringar utförs för att analysera dropparnas rörelse under påverkan av tyngdkraft och luftström. Resultaten ger insikter om de faktorer som påverkar dropparnas beteende och validerar modellernas noggrannhet genom fysiska tester. Forskningen diskuterar även studiens begränsningar och dess implikationer för Volvo Cars, med målet att förbättra deras förmåga att förutsäga vattendroppars rörelse på deras fordon, vilket leder till effektivare vindtunneltester och säkrare fordon.
|
38 |
Developing a Cost Model For Combined Offshore Farms : The Advantages of Co-Located Wind and Wave EnergyBlech, Eva January 2023 (has links)
Previous research has displayed that multi-source farms provide an opportunity to reduce the cost of energy and improve the energy output quality. This thesis assesses the cost competitiveness of co-located wind-wave farms, specifically floating offshore wind (FLOW) turbines and CorPower’s wave energy converters (WEC). This research was conducted in collaboration with CorPower, a Swedish WEC developer. A cost model is generated, which calculates the levelized cost of energy (LCOE) utilizing a life-cycle cost analysis. The model is developed by combining CorPower’s existing cost model with an agglomeration of FLOW cost models from previous studies. An in depth literature research informs about synergies, which are translated into shared costs within the model. The cost model is applied to a site on the Northern coast of Portugal; the location of a FLOW farm project under development. Including wave energy, improves the annual energy production of the farm by up to 10%. However, the effects on power smoothing are negligible, due to the high seasonal variability of the wave resource and the minimal complementarity of the two energy sources. The LCOE of a 1GW 50% wind - 50% wave farm is 63€/MWh. The high initial investment costs of the wind farm results in the standalone wind LCOE of 73€/MWh. The strong capacity factor of the WECs cause the LCOE to reduce to 55€/MWh, when evaluating a standalone wave farm. In all co-location configurations, savings for FLOW and wave farm developers are exhibited. The highest savings are identified for small wind/wave arrays co-located in large farms. This results in an LCOE reduction of up to 4.5% for both wind and wave farm developers. The largest relative savings are found in the DEVEX costs and the electrical transmission installation costs. The identified cost calculations and savings are inline with previous studies. The savings are in the lower range compared to other studies, due to the conservative estimations of the degree of shared costs. The cost model provides a tool, that can be continuously updated with the most recent findings of cost inputs and wind-wave synergies, i.e. shared cost opportunities. This thesis’ results reflect how co-locating wind and wave farms can improve the cost-competitiveness of both technologies. Nevertheless, more in depth research is required to comprehend the full potential of co-located wind-wave farms. There is a necessity of collaboration between wind and wave industry members to ensure that the synergies and shared cost-opportunities identified, are fully exploited. / Tidigare forskning har visat att parker med flera källor ger möjlighet att minska energikostnaderna och förbättra energiproduktionens kvalitet. I den här avhandlingen utvärderas kostnadskonkurrenskraften hos samlokaliserade vind- och vågkraftsparker, särskilt flytande havsbaserade vindkraftverk (FLOW) och CorPowers vågenergiomvandlare (WEC). Denna forskning genomfördes i samarbete med CorPower, en svensk WEC-utvecklare. En kostnadsmodell genereras, som beräknar den nivellerade energikostnaden (LCOE) med hjälp av en livscykelkostnadsanalys. Modellen är utvecklad genom att kombinera CorPowers befintliga kostnadsmodell med en agglomeration av FLOW-kostnadsmodeller från tidigare studier. En djupgående litteraturstudie ger information om synergier, som översätts till delade kostnader i modellen. Kostnadsmodellen tillämpas på en plats på Portugals norra kust, där ett FLOW-anläggningsprojekt är under utveckling. Genom att inkludera vågenergi förbättras parkens årliga energiproduktion med upp till 10%. Effekterna på effektutjämningen är dock försumbara, på grund av vågresursens stora säsongsvariationer och de två energikällornas minimala komplementaritet. LCOE för en 1GW 50% vind - 50% vågkraftspark är 63€/MWh. De höga initiala investeringskostnaderna för vindkraftsparken resulterar i en LCOE för fristående vindkraft på 73 €/MWh. Den starka kapacitetsfaktorn för WECs gör att LCOE minskar till 55€/MWh, vid utvärdering av en fristående vågkraftspark. I alla samlokaliseringskonfigurationer uppvisas besparingar för FLOW och vågparksutvecklare. De största besparingarna identifieras för små vind-/vågkraftsparker som samlokaliseras i stora parker. Detta resulterar i en minskning av LCOE med upp till 4,5% för både vind- och vågparksutvecklare. De största relativa besparingarna finns i DEVEX-kostnaderna och installationskostnaderna för elektrisk överföring. De identifierade kostnadsberäkningarna och besparingarna är i linje med tidigare studier. Besparingarna ligger i det lägre intervallet jämfört med andra studier, på grund av de konservativa uppskattningarna av graden av delade kostnader. Kostnadsmodellen är ett verktyg som kontinuerligt kan uppdateras med de senaste rönen om kostnadsingångar och synergier mellan vind och våg, dvs. möjligheter till delade kostnader. Resultaten i denna avhandling visar hur samlokalisering av vind- och vågkraftsparker kan förbättra kostnadskonkurrenskraften för båda teknikerna. Det krävs dock mer djupgående forskning för att förstå den fulla potentialen hossamlokaliserade vind- och vågparker. Det finns ett behov av samarbete mellanvind- och vågkraftsindustrin för att säkerställa att de identifierade synergierna ochgemensamma kostnadsmöjligheterna utnyttjas fullt ut.
|
39 |
Navigating Sustainability : A case study exploring alternative energy sources for maritime shipping / Navigerar hållbarhet : En fallstudie som undersöker alternativa energikällor till fraktfartygNordenskiöld, Simon January 2024 (has links)
This master thesis studies alternative energy sources for maritime shipping in Sweden. With current climate goals, and a need for change, the maritime sector currently undergoes intense transitions. For shipping companies to lower their carbon footprint, the need to replace non decarbonised fuels is hence critical. With numerous alternatives, currently being developed, actors are phasing obstacles regarding which energy source that is most mature in terms of technical readiness as well as how adequate it will fulfil current climate goals. This study will analyse four different energy sources, liquid hydrogen (LH2), electro-methanol (emethanol), electro-ammonia (e-ammonia) and wind (sails), and answer which out of these energy sources will be most suitable for actors to adapt. To answer this question, the Technological Innovation System framework has been utilised, and the results has been applied to some chosen climate target actions developed by Swedish authorities. The findings proved that e-methanol currently is most mature and has reached most alignment with current climate goals, followed by LH2/wind and lastly e-ammonia. / Detta examensarbete studerar alternativa energikällor för fraktfartyg i Sverige. Med nuvarande klimatmål, och ett behov av förändring, genomgår den maritima sektorn intensiva omställningar. För att rederier ska kunna sänka sitt koldioxidavtryck är behovet att ersätta icke koldioxidneutrala bränslen därför stort. Med ett flertal alternativ, som för närvarande är under utveckling, står aktörer inför hinder angående vilken energikälla som är mest redo gällande teknikmognadsgrad samt hur adekvat den kommer att uppfylla nuvarande klimatmål. Denna studie kommer att analysera fyra olika energikällor, flytande väte (LH2), elektro-metanol (e-metanol), elektro-ammoniak (e-ammoniak) och vind (segel), och ta reda på vilka av dessa energikällor som är mest lämpad för aktörer att använda sig av. För att svara på denna fråga har ramverket Technological Innovation Systems använts och resultaten har tillämpats på några utvalda klimatmålsåtgärder som tagits fram av svenska myndigheter. Resultaten visade att e-metanol för närvarande är mest mogen och har nått mest anpassning till nuvarande klimatmål, följt av LH2/vind och slutligen e-ammoniak.
|
40 |
Dimensionering och konstruktion av passiv mekanisk pitch för småskaliga horisontalaxlade vindkraftverk / Design and construction of passive mechanical pitch for small-scale horizontal axis wind turbinesOljelund, David January 2020 (has links)
För vindkraftverk i mindre skala används i huvudsak två sätt att avlasta vid höga vindhastigheter, stallreglering och girning ur vind. En tredje metod är att pitcha rotorbladet till en mindre attackvinkel. Då minskar belastningen på rotorbladet samtidigt som effektgenerering kan bibehållas. Arbetet redovisar en konstruktion för en fjädrande passiv mekanisk pitch som avgränsats till att enbart dimensionera en vridfjäder och tre lager. Konstruktionen riktas mot horisontalaxlade vindkraftverk med tre rotorblad med en rotordiameter upp till 20m. Ett idealt rotorblad modelleras matematiskt för att ta fram dimensionerande krafter och moment. Utifrån detta kan sedan vridfjäder och lager dimensioneras. Konstruktionen tillsammans med dimensioneringen visar att belastning av rotorbladet kan reduceras samt att krafter som är kopplad till effekten kan hållas mer eller mindre konstant för vindhastigheter 16 till 24 m/s. Resultat av dimensionering visar att både vridfjäder och lager kan relativt enkelt anpassas till olika axeldiametrar. Slutsatserna blir att om dimensionering görs enligt arbetet är det, åtminstone i teorin, möjligt att uppnå det önskade beteendet för pitchen. För vidare arbete och verifiering rekommenderas bland annat att göra reella tester för vridfjädern för att bestämma dess precision på grund av fjäderns små vinkelutslag. / For small-scale wind turbines, there are mainly two ways of reducing loads at high wind speeds, stall regulation and yaw the rotor out of wind. A third method is to pitch the rotor blade to a smaller angle of attack. This reduces the load on the rotor blade while maintaining power generation. The following work presents a design for a spring based passive mechanical pitch that is limited to only dimensioning a torsion spring and three bearings. The design is aimed at horizontal axis wind turbines with three rotor blades with a rotor diameter up to 20m. An ideal rotor blade is mathematically modeled to produce the forces and torques needed in order to properly dimension the torsion spring and bearings. The design shows that the load of the rotor blade can be reduced and that forces connected to the power can be kept more or less constant for wind speeds 16 to 24 m / s. The results of sizing show that both the torsion spring and bearings can be adapted to different shaft diameters relatively easy. The conclusions are that if dimensioning is done according to the presented results, it is possible, at least in theory, to achieve the desired behaviour. For further development and verification it is recommended to do real tests for the torsion spring to determine its precision due to small angle displacement in the spring.
|
Page generated in 0.0324 seconds