• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 4
  • Tagged with
  • 37
  • 12
  • 12
  • 12
  • 12
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Möjligheter med KL-trä : Hur en betongstomme kan omformas till en KL-trästomme / Possibilities with CLT : A redesign of a concrete structure to a CLT structure

Töttrup, Hampus, Renström, Gunnar January 2018 (has links)
KL-trä är ett stommaterial som blir allt intressantare på marknaden. Kunskapen är hos mångakonstruktörer idag begränsad. Genom att utgå från en betongstomme, där många konstruktörer har goderfarenhet av projektering och dimensionering, kan en jämförelse mellan dessa två stommaterial vara relevant. Frågan som då kan ställas är hur en KL-trästomme dimensioneras enligt Eurokoderna och vadskillnaderna och dess konsekvenser på boarea och byggnadshöjd, i jämförelse med en betongstomme. Genom att för en byggnad göra om dess betongstomme till en KL-trästomme så kunde dessa skillnader undersökas. KL-trä eller korslimmat trä är ett skivmaterial av sammanlimmade brädor, där vartannat lager liggerkorslagt mot föregående lager. Denna uppbyggnad ger KL-träskivan bärförmåga i två riktningar ochkan användas som vägg- och bjälklagselement. KL-trä är ett stommaterial med låg vikt, jämfört medexempelvis betong, och har precis som andra lätta konstruktioner utmaningar med att uppfylla ljudkrav. Trä som utsätts för brand brinner med en konstant hastighet. Då kolskiktet som bildas har enisolerande effekt, brinner det med en låg hastighet. Detta gör det enkelt att dimensionera för brand. KL-trä har mindre fuktbetingade rörelser jämfört med konstruktionsvirke. Handlingar för en referensbyggnad med betongstomme erhölls av Kåver & Mellin. Med målet attbehålla byggnadens ursprungliga arkitektoniska kvaliteter utformades en ny byggnad i KL-trä därhänsyn togs till krav för bärighet, ljud, värmeisolering, brand och fukt. Resultatet som presenteras är en metod för dimensionering av KL-träväggar och -bjälklag. Därefterföljer en uppställning av typdetaljer för väggar och bjälklag, dess ingående material och till vilken gradkraven uppfyllts. Förslag till anslutningar mellan utvalda byggnadsdelar visas. Boarean minskade iförhållande till referensbyggnaden. Byggnadhöjden alternativt rumshöjden påverkas negativt. KL-träbyggnaden visades väga 118 ton mindre än referensbyggnaden. Vid val av KL-trästomme måste hänsyn tas till den ökade tjockleken av lägenhetsskiljande bjälklagväggar som kan leda till minskad area och ökad byggnadshöjd, och dess ekonomiska konsekvenser. Den påtagliga skillnaden i vikt är betydelsefull vid grundläggning och hantering av vindlaster.
32

Branddimensionering av CLT-element i bärande väggkonstruktioner : en komparativ studie mellan gällande normer och senaste forskningen / Fire protection design of CLT elements used as structural walls : a comparative study between current design codes and the latest scientific knowledge

Hallqvist, Stefan, Berkal, Cherif January 2018 (has links)
I takt med en ökad miljömedvetenhet har träbyggnation börjat premieras allt mer och sedan lagändringen 1994 som innebar att det blev tillåtet att uppföra höga hus med trästomme har utvecklingen snabbt gått framåt. Att korsvis bygga upp skikt av brädor och sammanfoga dessa till element har visat sig skapa en produkt med hög hållfasthet och låg vikt som är idealisk som stommaterial vid byggnation av stora och höga hus i trä. Dessa element har många namn men kallas ofta korslimmat trä och kommer i arbetet benämnas CLT, cross-laminated timber. Dess användning har ökat markant i Sverige och Europa de senaste decennierna och än ses ingen stagnation på efterfrågan.   Denna rapport behandlar relevanta teoretiska områden som måste tas i beaktning vid branddimensionering som exempelvis brandförloppet i en brandcell samt hur brandsäkerhetsklasser och brandtekniska byggnadsklasser bestäms och fastställs. Dimensioneringsmetoder av laster och hållfasthet i både brottgräns och i brandfallet förklaras genomgående för skapa en tydlig bild av hela branddimensioneringsprocessen. Brist på direkt information om hur hållfastheten av resttvärsnitten ska behandlas och beräknas har gjort arbetet utmanande men med hjälp från Maija Tiainen från Sweco structures Helsingforskontor har arbetet kunnat färdigställas och bli fullständigt.   Den viktigaste delen i rapporten är dock själva inbränningen och förkolningen av elementen som beräknas med hjälp av två olika metoder. Den ena återfinns i den europeiska standarden Eurokod 5: del 1-2 och den andra, som baseras på den absolut senaste forskningen gällande träkonstruktioner och brand, är hämtad från handboken Brandsäkra trähus version 3. Den senare metoden kommer ligga till grund för en uppdatering av Eurokod 5 i framtiden.   För att kunna jämföra de två metoderna och ge en nyanserad bild av dessa valdes fyra väggtyper ut som beräknades med samma förutsättningar. Det vill säga skyddade med två lager gips och utsatta för en 90 minuters ensidig standardbrand.   Resultatet visade på skillnader mellan metoderna där en tydlig och definitiv sådan var storleken på resttvärsnittet då det icke lastupptagande skiktet, , visade sig vara mycket större i beräkningarna enligt metoden i Brandsäkra trähus version 3. På grund av elementens uppbyggnad, korsvis lagda skikt där endast vartannat skikt är lastbärande, betyder detta inte nödvändigtvis att det resulterar i en skillnad gällande bärförmåga i brandfallet mellan de två metoderna.   Trots att metoden i Brandsäkra trähus version 3 är mer konservativ gällande bärförmåga och leder till ett mindre resttvärsnitt efter brand anser författarna att denna metod bör användas i väntan på en inarbetning av metoden i Eurokoden. Detta då den till skillnad från Eurokoden är utformad och framtagen för att kunna behandla CLT och då säkerheten är viktigast i sammanhanget måste brandens ökade påverkan på materialet enligt den senaste forskningen tas på allvar och tvärsnittet dimensioneras därefter. / In recent years, a growing environmental awareness have led to an increase in timber buildings and since the 1994 amendment that made it possible to build tall houses with timber structures the progress in the field have seen an substantial increase. To build an element of perpendicularly placed layers of solid-sawn lumber have proven to be an effective way to obtain a product with good strength-to-weight ratio that is ideal for use in tall timber buildings. These elements go under a lot of different names but are often referred to as cross-laminated timber and will be called CLT in this report. The use of this product have these past decades increased substantially both in Sweden and in Europe and the demand does not seem to stagnate nor decrease in the near future.   The report is comprised of relevant theoretical sections that must be taken into account when designing a structures fire protection such as the development of a fire in fire compartment, how to define and determine a structures class of fire resistance and hence required fire protection time for said structure. The basis of design in regards to loads and compressive/flexural strength of the material is thoroughly explained in order to account for the whole fire protection design processes. The lack of information regarding compressive and flexural strength of the residual cross-section was challenging but with the help from Maija Tiainen from Sweco structures Helsinki office the report could be completed.   The most important part of the report is the theory and calculation with regards to the charring depth which is calculated by two different methods. The first one is presented in the European standard Eurocode 5: part 1-2 and the other one, that is based on the latest scientific knowledge with regards to timber structures and fire, is found in the technical guide Brandsäkra trähus version 3. The aforementioned method will form the basis for the upcoming update of Eurocode 5.   In order to be able to compare the two methods four wall types was chosen and designed based on the same conditions. Namely protected by two layers of gypsum plasterboards as fire protection and exposed to a 90 minutes one-sided standard fire.   The result showed differences between the methods where a clear difference was the size of the residual cross-section due to the fact that the zero-strength layer, , was notably larger when calculating with the method presented in Brandsäkra trähus version 3. This does not necessarily affect the elements bearing capacity when calculating with the two different methods due to the elements perpendicularly placed layers where only every other layer is load bearing.   Although the method presented in Brandsäkra trähus version 3 are more conservative with regards to bearing capacity and will lead to a smaller residual cross-section the authors of this report recommend the use of said method pending incorporation into the Eurocode. The motivation for this suggestion is that the method is designed to explicitly handle CLT and since safety is the most important aspect in this context it is vital to acknowledge the apparent increased affect from a fire on the material according to the latest scientific knowledge and design the cross-section accordingly.
33

Flerbostadshus i trä och dess betydelse för välmåendet i bostadsmiljön / Apartment Building In Wood And Its Significance For The Well-Being Of The Living Environment

Cakici, Baran, Blennestrand, Robin January 2022 (has links)
The shortage of housing increases the demand for apartment buildings, while pressing climate change forces the construction sector to reduce its carbon footprint. In this context, solid wood and engineered wood products have been shown to be a more sustainable alternative to traditional building materials.  The present study investigates how living in wooden high-rise apartments impacts the wellbeing of its occupants. Nine people currently living in high-rise wooden buildings were interviewed using semi-structured interviews. The data was processed using a qualitative content analysis. The residents expressed having a “clear conscience” regarding their choice of housing and were proud to contribute to sustainability from an ecological perspective. In addition, the majority of the participants linked exposed wood in the indoor and outdoor living environment to feelings of comfort and wellbeing. In general, the touch of wood was perceived as softer, warmer and more alive than other materials such as stone. The conclusion points towards the outdoor and indoor environment of wooden high-rise buildings having a positive effect on the wellbeing of its residents.
34

Tillämpning av träbaserat modulväggsystem för påbyggnad av efterkrigstidens flerbostadshus : Utifrån energikrav och ekonomiska förutsättningar / Application of Wood Based Module Wall System for Vertical Attic Extension of Post-war Residential Building : By Energy Demand and Economic Preconditions

Samuelsson, Jimmy, Debes, Yahya January 2017 (has links)
Syfte: Nya svenska energikrav definieras som nära-nollbyggnader för både nybyggnation och renovering, där man strävar efter en årlig balans mellan ingående och utgående energi för byggnaden. Påbyggnad genom prefabricerade modulsystem med bärande väggar av korslimmat massivträ har genom internationella studier visat sig både tids- och kostnadseffektiv vid renovering. Målet med rapporten är att undersöka möjligheten att tillämpa detta påbyggnadssystem för svenska renoveringsprojekt av efterkrigstidens flerbostadshus som både är kostnadseffektivt och som klarar nya svenska energikrav. Metod: Rapporten syftar till att besvara frågeställningarna genom en fallstudie. Inledningsvis, under en litteraturstudie, beskrivs incitament till påbyggnation vid renovering. Utefter en dokumentanalys av referensbyggnaden, utförs sedan energi- och kostnadsjämförelser mellan påbyggnation av korslimmade massivträväggar och platsbyggd träregelkonstruktion. Resultat: Svenska efterkrigstidens bostadsbestånd visar sig, via renovering och påbyggnation, ha hög potential för att positiv påverka den i Sverige genomsnittliga specifika energianvändningen samtidigt som det erbjuder snabb och kostnadseffektiv urban bostadsförtätning. Den värmeisolerande förmågan för korslimmat massivträ är, för en påbyggnad, likvärdigt det av platsbyggd träkonstruktion. Beräkningarna visar däremot hur byggnation från efterkrigstiden har svårt att uppnå krav för nära-nollenergihus. Kostnad för montering av påbyggnadsstomme och innerväggar m.m. visar på ca 2,7 % besparing för förslag av korslimmat massivträ. Konsekvenser: Rapporten lyfter fram möjligheterna kring renovering av svenska flerbostadshus från efterkrigstiden och fördelarna att göra detta i kombination med påbyggnation. Det finns goda förutsättningar för implementering av korslimmade massivträväggar även i svenska påbyggnadsprojekt och detta till något lägre pris och arbetstid gentemot platsbyggd konstruktion. Trots att detta vilar mycket på valet av prefabricering, har undersökningen lyckats exponera ett befogat alternativ för påbyggnadsprojekten i framtiden. Eventuella svårigheter i att uppnå nya energikrav vid renovering av äldre bostadsbestånd har även lyfts fram i rapporten. Begränsningar: Kontroll av bärförmåga för referensbyggnaden via konstruktionsmässiga beräkningar genomförs inte i denna rapport. Beräkning av livscykelkostnad ingår inte i detta arbete. Rapporten fokuserar istället på ekonomisk effektivitet i produktionsskedet. Rapporten fokuserar sin undersökning kring åtgärder för energianvändning och berör inte eventuella åtgärder för t.ex. högre tillgänglighet. / Purpose: New Swedish energy requirements are defined as Near Zero Energy Buildings for both new construction and renovation, with the purpose of balancing energy entering and exiting the building. Vertical attic extensions through prefabricated module system containing loadbearing walls of cross laminated timber has, by international studies, shown the potential for time and cost efficiency during renovation projects. The purpose of this inquiry is to examine the possibility to apply this extension system for Swedish renovation projects on post-war residential buildings that are both cost effective and that satisfies new Swedish energy regulations. Method: The report aims to answer the questions through a case study. Initially a literature study describes the incentives of vertical attic extensions and renovation. Then through a document analysis of a reference building, energy and cost comparisons are carried out between an attic extension of cross laminated timber and wood construction assembled on site. Findings: The Swedish post-war housing stock shows high potential through renovation and attic extension, to positively influence the Swedish average specific energy use while simultaneously providing fast and cost effective urban densification. The heat insulating performance of cross laminated timber is, for an attic extension, equivalent that of an on-site assembled wood construction. However, calculations shows difficulties for post-war housing stock to achieve the requirements for Near Zero Energy Buildings. The cost for assembling extending structure and interior walls etc. reveals approximately 2,7 % savings with cross laminated timber. Implications: The report brings forth the possibilities regarding renovation of the Swedish post-war stock of multifamily housing and the advantages of doing so in combination with vertical attic extensions. There are good conditions for implementation of cross laminated timber walls even in Swedish extension projects, while having the potential to lower costs slightly and saving time in relation to on site construction. Even though the results depend a lot on the choice of prefabrication, the study has exposed a valid alternative for future attic extension projects. The report also reveals potential difficulties in achieving new energy requirements for renovation of older housing stock. Limitations: Verification of load capacity through constructional calculations are not performed in this inquiry. Calculating the life-cycle cost is not a part of this project, which instead focuses on economic efficiency during production. The report focuses its research at energy-saving measures and doesn’t concern measures regarding for example higher accessibility.
35

Förstärkning av träregelstomme med KL-trä : Teoretisk utvärdering av olika ytterväggstyper / Strengthening of light frame timber walls with CLT : Evaluation of different wall types

Larsson, Joel January 2020 (has links)
På senare tid har intresset för och viljan att bygga flerbostadshus i trä ökat och medfört en trend att bygga allt högre hus med stomme av trä. En aktör är Lindbäcks Bygg som bygger flerbostadshusi trä med volymelement och lätt regelstomme. Idag begränsas dock möjligt antal våningar med regelstomme till 6 – 8 våningar. Ett relativt nytt material inom träbyggnadstekniken är korslimmat trä (KL-trä) vars användning gjort det möjligt att bygga högre byggnader i trä. Examensarbetets syfte är att studera olika lösningar för hur Lindbäcks regelstomme kan förstärkas med KL-trä, vilket kan göra det möjligt att bygga allt högre flerbostadshus i trä. Samt att jämföra denna lösning med den idag använda regelstommen utan KL-trä. Studien har avgränsats till att enbart behandla ytterväggar. För att uppskatta rimliga laster på ytterväggar i en flervåningsbyggnad togs en principbyggnad (ihopsatt av ett antal volymelement) fram. I beräkningar tillämpades ett antal olika ytterväggstyper, en med den idag användaregelstommen (referensvägg) samt fem med regelstomme i kombination med KL-skivor i olika tjocklekar. För principbyggnaden kontrollerades genom beräkningar hur högt det är möjligt att bygga vid tillämpning av vardera ytterväggstyp. De olika ytterväggstyperna med KL-trä jämfördes även med referensytterväggen utifrån U-värde samt kostnad. Idag används KL-trä ibland av Lindbäcks och då som stabiliserande väggar. I deras fabriker tillämpas en lösning där KL-träskivorna fälls in mellan syll och hammarband tillsammans med reglarna. Beräkningar har visat att det, för principbyggnaden, med denna lösning är möjligt att bygga maximalt 2 våningar högre jämfört med referensytterväggen, detta för den bästa av ytterväggstypernaförstärkta med KL-trä. Det som begränsar ett högre antal våningar är trycket vinkelrätt fiberriktningen på syllen under KL-skivorna. Beräkningar visar att det finns en potential att med regelstomme förstärkt med KL-trä kunna bygga ännu högre om en annan lösning används där KL-träskivorna placeras på utsidan av syll, hammarband och reglar istället för infälld mellan syll och hammarband. Med denna lösning undviks tryck vinkelrätt fiberriktningen på syll under KL-skivor och KL-skivans kapacitet kan utnyttjas effektivare då normalkraftskapaciteten för själva skivan blir den begränsande faktorn för hur högt det går att bygga. Enligt beräkningar är det, för principbyggnaden, med denna lösning möjligt att bygga uppemot 8 våningar högre än med referensytterväggen. När KL-trä används i stommen ökar energiförlusterna genom väggen, dvs. U-värdet ökar, då reglar med mellanliggande isolering ersätts av KL-trä med sämre värmeledningsförmåga. Enligt beräkningar uppskattas U-värdet öka jmf. med för referensyttervägg, detta med ca. 20 – 40 % beroende på ytterväggstyp. Ökningen kan dock begränsas till ca. 0,4 – 14 % genom införande av ett 45 mm installationsskikt med isolering på väggens insida. Även kostnaden för ytterväggstyper med regelstomme förstärkt med KL-trä uppskattas öka jmf. med uppskattad kostnad för referensyttervägg. Detta med uppskattningsvis 40 – 50 %, vilket till huvudsak är en följd av ökad materialkostnad för KL-skivor som delvis ersätter reglar med mellanliggande isolering. / Today there is an increased interest in building taller buildings with timber. Lindbäcks Bygg is one of companies that uses modular construction with light timber stud frames. However, a problem with light timber frames is that the building height is limited to roughly 6 - 8 stories. A relatively new product in timber engineering is cross laminated timber (CLT) and the use of this product have made it possible to build taller timber buildings. The purpose of this study is to investigate different solutions for how Lindbäcks can strengthen their stud frames by using CLT and thereby build taller buildings. The difference with respect to U-value and cost between the walls strengthened width CLT and the typical stud frame wall, that is used today, is also studied. The study has been limited to exterior walls only. A multi-storey building consisting of several modules/volume elements has been used to estimate reasonable loads on the exterior walls. Different wall types, one with the ordinary stud frame (the reference wall) and five types of stud walls strengthened with different thicknesses of CLT, have been investigated. The maximal number of storeys that can be build, the U-value and the cost were determined by calculations for each of the studied wall types and were compared with the results for the reference wall. Today, Lindbäcks Bygg sometimes uses CLT for stabilizing walls. In their factories, they use a solution in which the CLT-plate is placed between the top and bottom plate together with the studs. According to the calculations it is, with this solution, possible to build up to 2 storeys higher then with the reference wall. The limiting factor for how high it is possible to build, is compression perpendicular to the grain on the bottom plate underneath the CLT-plate. If a solution where the CLT-plate is placed on the outside of the frame (consisting of studs, top and bottom plate) is used instead of between the top and bottom plate does the calculations show that a higher number of storeys is possible. With this solution, the compression perpendicular to the grain underneath the CLT-plate is avoided and the limiting factor is instead the compression strength of the CLT-plate. This means that the CLT can be used more efficiently. Calculations show that it is possible to build up to 8 storeys higher with this solution compared to what is possible with the reference wall. With CLT increases the energy losses through the wall, i.e. increased U-value, since studs with insulation in between is partially replaced with CLT that has worse thermal conductivity. According to the calculations, the U-value is 20 – 40 % higher (depending on the wall type) compared to the reference wall. The increase in U-value can be limited to 0.4 – 14 % by adding an extra layer with 45 mm insulation on the inside of the CLT-plate. The cost for the wall types strengthened with CLT is also higher compared to the estimated cost for the reference wall. The main reason for this is increased cost of materials since the studs with insulation in between is partially replaced with the more expensive CLT, which is an engineered wood product. The increase in cost is estimated to roughly 40 – 50 % of the cost for the reference wall.
36

Mechanics of Cross-Laminated Timber

Buck, Dietrich January 2018 (has links)
Increasing awareness of sustainable building materials has led to interest in enhancing the structural performance of engineered wood products. Wood is a sustainable, renewable material, and the increasing use of wood in construction contributes to its sustainability. Multi-layer wooden panels are one type of engineered wood product used in construction. There are various techniques to assemble multi-layer wooden panels into prefabricated, load-bearing construction elements. Assembly techniques considered in the earliest stages of this research work were laminating, nailing, stapling, screwing, stress laminating, doweling, dovetailing, and wood welding. Cross-laminated timber (CLT) was found to offer some advantages over these other techniques. It is cost-effective, not patented, offers freedom of choice regarding the visibility of surfaces, provides the possibility of using different timber quality in the same panel at different points of its thickness, and is the most well-established assembly technique currently used in the industrial market. Building upon that foundational work, the operational capabilities of CLT were further evaluated by creating panels with different layer orientations. The mechanical properties of CLT panels constructed with layers angled in an alternative configuration produced on a modified industrial CLT production line were evaluated. Timber lamellae were adhesively bonded in a single-step press procedure to form CLT panels. Transverse layers were laid at a 45° angle instead of the conventional 90° angle with respect to the longitudinal layers’ 0° angle. Tests were carried out on 40 five-layered CLT panels, each with either a ±45° or a 90° configuration. Half of these panels were evaluated under bending: out-of-plane loading was applied in the principal orientation of the panels via four-point bending. The other twenty were evaluated under compression: an in-plane uniaxial compressive loading was applied in the principal orientation of the panels. Quasi-static loading conditions were used for both in- and out-of-plane testing to determine the extent to which the load-bearing capacity of such panels could be enhanced under the current load case. Modified CLT showed higher stiffness, strength, and fifth-percentile characteristics, values that indicate the load-bearing capacity of these panels as a construction material. Failure modes under in- and out-of-plane loading for each panel type were also assessed. Data from out-of-plane loading were further analysed. A non-contact full-field measurement and analysis technique based on digital image correlation (DIC) was utilised for analysis at global and local scales. DIC evaluation of 100 CLT layers showed that a considerable part of the stiffness of conventional CLT is reduced by the shear resistance of its transverse layers. The presence of heterogeneous features, such as knots, has the desirable effect of reducing the propagation of shear fraction along the layers. These results call into question the current grading criteria in the CLT standard. It is suggested that the lower timber grading limit be adjusted for increased value-yield. The overall experimental results suggest the use of CLT panels with a ±45°-layered configuration for construction. They also motivate the use of alternatively angled layered panels for more construction design freedom, especially in areas that demand shear resistance. In addition, the design possibility that such 45°-configured CLT can carry a given load while using less material than conventional CLT suggests the potential to use such panels in a wider range of structural applications. The results of test production revealed that 45°-configured CLT can be industrially produced without using more material than is required for construction of conventional 90°-configured panels. Based on these results, CLT should be further explored as a suitable product for use in more wooden-panel construction. / <p>External cooperation: Martinson Group AB and Research Institutes of Sweden (RISE)</p>
37

Läkande rum : - ett examensarbete om arkitektur, psykiatri och läkande miljöer / Curative Spaces : - a Book about Architecture, Psychiatry and healthy Environments and a Vision for Psychiatric Healthcare in the Future

Kallstenius, Marie-Louise January 2011 (has links)
Projektets syfte är att försöka utröna hur en visionär psykiatri skulle kunna se ut i framtiden. Jag frågade mig om man som arkitekt kan komma med en vision som är en lösning på psykiatrins problem. Hur gör man för att maximera de läkande faktorerna så att patienter återhämtar sig så fort och fullständigt som möjligt? Projektet är också ett försök att förmänskliga en av de stora insitutioner vi är beroende av i samhället och har resulterat i en bok i ämnet och ett designprojekt.

Page generated in 0.0499 seconds